Datasheet
®
1/10
Table 1: Main Features
DESCRIPTION
Available either in through-hole or surface-mount
packages, the BTA12, BTB12 and T12 triac series
is suitable for general purpose AC switching. They
can be used as an ON/OFF function in applica-
tions such as static relays, heating regulation, in-
duction motor starting circuits... or for phase
control operation in light dimmers, motor speed
controllers,...
The snubberless versions (BTA/BTB...W and T12
series) are specially recommended for use on
inductive loads, thanks to their high commutation
performances.
Logic level versions are designed to interface
directly with low power drivers such as
microcontrollers.
By using an internal ceramic pad, the BTA series
provides voltage insulated tab (rated at
2500V
RMS
) complying with UL standards (File ref.:
E81734).
Symbol Value Unit
I
T(RMS)
12 A
V
DRM
/V
RRM
600 and 800 V
I
GT (Q
1
)
5 to 50 mA
BTA12, BTB12 and T12 Series
12A TRIACS
REV. 8July 2005
SNUBBERLESS™, LOGIC LEVEL & STANDARD
Table 2: Order Codes
Part Number Marking
BTA12-xxxxxRG
See page table 8 on
page 9
BTB12-xxxxxRG
T12xx-xxxG
T12xx-xxxG-TR
T12xx-xxxR
A2
A2
A1
G
D
2
PAK
(T12-G)
G
A2
A1
G
A2
A2
A1
TO-220AB Insulated
(BTA12)
TO-220AB
(BTB12)
G
A2
A2
A1
I
2
PAK
(T12-R)
A2
A1
G