7. Transceiver Information
The User and the Installer should be aware that changes and modifications to the equipment not expressly
approved by Master Meter could void warranty and the user's authority to operate the equipment.
Professionally trained personnel should install the equipment.
The Sonata is equipped with an internal antenna/transmitter and 1) must be installed at a minimum
separation distance of at least 20 cm from all persons, and 2) must not be co-located or operating in
conjunction with any other antenna or transmitter.
RF Radio Characteristics
Parameter
Value
Unit
Operating Frequency:
450-470, License band
MHz
Network Topology
Star
Modulation
4GFSK
Maximum Transmitter output power
+34
dBm
Bandwidth
6.25
KHz
Data Rate
4.8kbps
Receiver sensitivity, typical
-115dBm@4.8kbps
dBm
Antenna Type
Built in Antenna
Standards Compliance
Region
Category
Standard
United States
Canada
EMC/Radio
47CFR FCC Part 90 and Part 15 subpart B Class B
RSS-119 and ICES-003 Class B