User's Manual
ST Engineering Telematics Wireless Ltd
16
◦ After approximately 18 seconds of being ON, the luminaire will dim to about 50%, if dimming is
supported.
◦ After approximately 9 seconds, the luminaire will change to 5% if dimming is supported.
◦ After approximately 10 seconds, the luminaire will return to 100%.
◦ After approximately 8 seconds, the luminaire will turn OFF (light out).
◦ After approximately 12 seconds, the luminaire will return to whatever operational state the
internal photocell or CMS schedule determines.
In case of dimming method dali:
◦ After approximately 27 seconds of being ON, the luminaire will dim to about 50%, if dimming is
supported.
◦ After approximately 4 seconds, the luminaire will change to 5% if dimming is supported.
◦ After approximately 10 seconds, the luminaire will return to 100%.
◦ After approximately 6 seconds, the luminaire will turn OFF (light out).
After approximately 12 seconds, the luminaire will return to whatever operational state the internal
photocell or CMS schedule determines.
3. If the luminaire does not complete the verification procedure, follow the basic troubleshooting steps
in 9.2. Troubleshooting:
4. If the luminaire successfully finished the “Auto Detection and Verification” procedure, the LCU
physical installation is complete.
Note: Each time the main power to the pole is lost, the “Auto Detection and Verification”
procedure is executed when power is restored.
9.2 Troubleshooting
If the “Auto Detection and Verification” procedure is not successful, troubleshoot as follows:
To troubleshoot a LCU NEMA installation:
1. Remove the LCU plug by twisting the plug counterclockwise.
2. Wait 15 seconds.
3. Reseat the LCU in the receptacle securely.
As soon as the LCU is reseated, the “Auto Detection and Verification” procedure will start.
4. Observe the ON/OFF sequence.
5. If the “Auto Detection and Verification” procedure fails again, select and install a different LCU.
6. If the verification procedure fails with a different LCU, verify the following:
◦ The lamp driver and luminaire are working correctly.
◦ The receptacle is installed correctly.
For additional troubleshooting steps, contact Telematics support. See 11. Contact Details.