8. Installation Overview
Important Note: Read the entire Installation Guide before beginning the installation process.
It is assumed that the customer has installed the following:
• NEMA ANSI C136.10-2010 and C136.41-2013 compliant receptacle in the luminaire cover.
• Required customer-supplied voltage and current surge protection.
Preparing for installation is different depending on which, if any, GPS coordinate obtaining components
are in the LCU NEMA. See the Pre-Installation topic in each of the following chapters
Note: The only acceptable format for importing GPS coordinates into the CMS is decimal
degrees. See Appendix A. - About GPS Coordinate Formats.
The installation process consists of different steps depending on the following:
• Telematics GPS component
• Type of network
• LCU information preloaded into the “Equipment Inventory”
• No GPS component and no preloading
In order to verify the installation by observing the “Auto Detection and Verification” ON/OFF light
sequence:
• If the “Auto Detection and Verification” procedure was configured to work only during daylight
hours, schedule the installation accordingly.
• Prepare an easy to use list of the expected ON/OFF light sequence, including dimming if configured.
8.1 Installation with the GPS Component
1. Install the LCU NEMA. See 9. Installing the LCU NEMA.
2. Observe the ON/OFF light sequence that verifies the LCU installation. See 9.1 Observing the “Auto
Detection and Verification” Procedure.
3. After all NEMAs are installed, alert the CMS Administrator to start commissioning.