Installation Manual


Master Meter, Inc. 101 Regency Pkwy, Mansfield, TX 76063 T: 817-842-8000 F: 817-842-8100 MasterMeter.com
5. Product Specifications
Figure 1) Specification Tables
Dimensions
Length x width x height
Inches
5.2 x 3.6 x 2
Weight
Product Weight
Lbs
2.2
Environment (worst case)
Submerge time (@0°, 25°, 40°C)
Hours
168
Temperature
Operating temperature range for basic operation (transmission of
last 12 reads, no data logger transmission)
°C
-20 to 65
Operating temperature range for data logger transmission
°C
-10 to 65
Storage temperature range
°C
-30 to 80
Humidity
Maximal humidity at temperature of 65 °C
%
95
Chemical exposure
Oliec acid + Hydraulic oils + Fuel+ Other Chemicals
Hours
72
Connector Types
Nicor, Bare Wire
Regulatory
UL, FCC, IC
Figure 2) Encoder Compatibility List
Master Meter
Elinx, AccuLinx Digital Encoders All Sizes
Sensus
ICE, Ipearl, Accustream Digital Encoders All Sizes
Mueller
Mueller Translator Register All Sizes
Neptune
ARB II VI Encoded Registers
Figure 3) LED Indicator Behavior
Details
LED
LED should indicate in case of magnet sensing
5 seconds slow blinks
(1sec on / 1 sec off)
Indication when unit enters to fast mode
5 seconds fast blinks
(0.5Sec on / 05sec off)
Indication for magnet release, 8 seconds after magnet
sensing
1 blink, 2 seconds duration
After magnet removal when unit enters to install mode
and no parent acquirement
5 seconds slow blinks
(1sec on / 1 sec off)
Unit acquired a parent, and it still in install mode
2 seconds fast blinks
(0.5Sec on / 05sec off)
Device is associated to a parent, got configuration from
Command center.
5 seconds fast blinks
(0.5Sec on / 05sec off)