Data Sheet

11
Ecoflex
®
10
Technical data
Centre conductor ... stran. copper, oxygen free, 7 x 1,0 mm
Centre conductor Ø ......................................... 2,85 mm
Dielectric ................................... PE, low-loss Compound
Dielectric Ø ......................................................7,25 mm
Outer conductor 1 ......................... copperfoil, PE-coated
Shielding factor ................................................... 100 %
Outer conductor 2 .......................................copper braid
Shielding factor ..................................................... 72 %
Sheath ........................................black PVC, UV-resistant
Outer diameter Ø ............................................. 10,2 mm
Weight ..............................................................131 g/m
Min. bending radius . . one single bending .............40 mm
15 repeated bendings ......... 80 mm
Temperature range ... storage .....................-70 to +85°C
installation ................-40 to +60°C
operation ..................-55 to +85°C
Pulling strength .................................................... 5 daN
Typ. attenuation (dB/100 m @ 2C)
5 MHz ................. 0,8
10 MHz ................. 1,2
50 MHz ................. 2,8
100 MHz ................. 4,0
144 MHz ................. 4,9
200 MHz ................. 5,8
300 MHz ................. 7,3
432 MHz ................. 8,9
500 MHz ................. 9,6
800 MHz ............... 12,5
1000 MHz .............14,2
1296 MHz .............16,5
1500 MHz .............17,9
1800 MHz .............19,9
2000 MHz .............21,2
2400 MHz .............23,6
3000 MHz .............27,0
4000 MHz .............32,2
5000 MHz .............37,0
6000 MHz .............41,5
Electrical specifications
Impedance ............................................................. 50
Capacity ............................................................ 78 pF/m
Velocity factor .........................................................0,85
fmax .................................................................... 6 GHz
Screening efficiency @ 1 GHz ............................. > 90 dB
DC-resistance: Centre conductor ....................... 3,3
/km
Outer conductor ....................... 8,4
/km
RF peak voltage ...................................................... 1kV
Typ. Attenuation (dB/100 m) @ 20°C
Frequency (MHz)
Ecoflex 10 RG 213/U RG 58/U
Capacity ....................78 pF/m ......101 pF/m .. 102 pF/m
Velocity factor ............. 0,85 ............ 0,66 .......... 0,66
Attenuation (dB/100 m)
10 MHz ................... 1,2 ............ 2,0 .......... 5,0
100 MHz ................... 4,0 ............ 7,0 ..........17,0
500 MHz ................... 9,6 ............ 17,0 .......... 39,0
1000 MHz ................... 14,2 ............ 22,5 .......... 54,6
3000 MHz ................... 27,0 ............ 58,5 .......... 118
Typ. Return loss
Frequency (GHz)
Max. power handling (W @ 40°C)
10 MHz ............3960
100 MHz ............1210
500 MHz ..............510
1000 MHz ..............350
2000 MHz ..............230
3000 MHz ..............180
4000 MHz ..............150
5000 MHz ..............130
6000 MHz ..............120
100 dB
10 dB
1 dB
0,1 dB
30 100 1000 6000
0 db
- 5 db
-10 db
-15 db
-20 db
-25 db
-30 db
-35 db
-40 db
0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0
Due to production tolerances the RTL may have different characteristics.
www.ssb-electronic.com
© SSB-Electronic GmbH - Specifications are subject to change