Data Sheet
© SSB-Electronic GmbH - Specifications are subject to change
www.ssb-electronic.com
Ecoflex
®
15 Plus
Technical data
Centre conductor ........................Hybrid, aluminium core,
..............................................copper shield, 7 x 1,55 mm
Centre conductor Ø ............................................4,5 mm
Dielectric .................................... PE, low-loss Compound
Dielectric Ø ......................................................11,3 mm
Outer conductor 1 ......................Cu-Folie, PE-beschichtet
Shielding factor ................................................... 100 %
Outer conductor 2 ....................................... Cu-Geflecht
Shielding factor ..................................................... 72 %
Sheath .................................PVC schwarz, UV-stabilisiert
Outer diameter Ø ............................................. 14,6 mm
Weight ...............................................................200 g/m
Min. bending radius .....one single bending ...........70 mm
15 repeated bendings ..... 140 mm
Temperature range .....storage ...................-70 bis +85°C
installation .............-40 bis +60°C
operation ...............-55 bis +85°C
Pulling strength ...................................................10 daN
Typ. attenuation (dB/100 m @ 20°C)
5 MHz ................... 0,58
10 MHz ................. 0,83
50 MHz ................. 1,87
100 MHz ............... 2,67
144 MHz ............... 3,23
200 MHz ............... 3,83
300 MHz ............... 4,75
432 MHz ................. 5,8
500 MHz ................. 6,2
800 MHz ................. 8,0
1000 MHz ...............9,1
1296 MHz .............10,5
1500 MHz .............11,4
1800 MHz .............12,6
2000 MHz .............13,4
2400 MHz .............14,9
3000 MHz .............16,9
4000 MHz .............20,0
5000 MHz .............22,9
6000 MHz .............25,6
8000 MHz .............30,5
Max. power handling (W @ 40°C)
10 MHz ................6710
100 MHz ..............2070
500 MHz ................890
1000 MHz ..............610
2000 MHz ..............410
3000 MHz ..............330
4000 MHz ..............280
6000 MHz ..............220
8000 MHz ..............180
Electrical specifications
Impedance ............................................................. 50
Capacity ............................................................ 77 pF/m
Velocity factor ..........................................................0,86
fmax ..................................................................... 8 GHz
Screening efficiency @ 1 GHz ............................ > 90 dB
DC-resistance: Centre conductor ....................... 2,2
/km
Outer conductor ...................... 5,15
/km
RF peak voltage ................................................. 1,55 kV
Typ. Attenuation (dB/100 m) @ 20°C
Frequency (MHz)
Ecoflex
®
15 Plus RG 213/U RG 58/U
Capacity .................... 77 pF/m ....... 101 pF/m ...102 pF/m
Velocity factor ..............0,86 ............0,66 .......... 0,66
Attenuation (dB/100 m)
10 MHz ...........................0,83 ........... 2,0 ........... 5,0
100 MHz .........................2,67 ........... 7,0 .......... 17,0
500 MHz ..........................6,2 .......... 17,0 ......... 39,0
1000 MHz ........................9,1 .......... 22,5 ......... 54,6
3000 MHz .......................16,9 .......... 58,5 ..........118
100 dB
10 dB
1 dB
0,1 dB
10 100 1000 10000
Typ. Return loss
Frequency (GHz)
-10 db
-15 db
-20 db
-25 db
-30 db
-35 db
-40 db
0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 7,0 7,5 8,0
Due to production tolerances the RTL may have different characteristics.