Cut Sheet

104
www.ssac.com • 800-843-8848 • fax: 605-348-5685
Features:
All solid state – no moving parts or contacts
Onboard adjustable ash rate
Loads up to 20A
High inrush up to 200A
Universal voltage 24 to 240VAC
Approvals:
FSU1000 / FS100 SeriesFlashers
Technical Data
Operation ....................... ON/OFF recycling solid-state asher (continuous duty)
Flash Rate ....................... Adjustable 10 - 100 FPM
ON/OFF Ratio ................... 50%
Input
Range/Frequency ................ 24 to 240VAC/50/60Hz
Output
Load Type ....................... Inductive, resistive, or incandescent
Maximum Load Rating ............ 1, 6, 10, or 20A steady state
Inrush. . . . . . . . . . . . . . . . . . . . . . . . . . . 10 times steady state current
Mechanical
Mounting* ....................... Surface mount with one #10 (M5 x 0.8) screw
Dimensions ...................... 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Termination ..................... 0.25 in. (6.35 mm) male quick connect terminals
Protection
Circuitry ........................ Encapsulated
Environmental
Operating / Storage Temperature .. -20° to 60°C (240VAC +50°C) / -40° to 85°C
Weight .......................... 1A units: 2.4 oz (68 g)
> 6A units: 3.9 oz (111 g)
*Units rated > 6A must be bolted to a metal surface using the included heat sink compound.
The maximum mounting surface temperature is 90°C.
Available Models:
Specications
FSU1000
FSU1003
FSU1004
Auxiliary Products:
• Female quick connect:
P / N : P 1 0 1 5 - 1 3 ( A W G 1 0 / 1 2 )
P/N: P1015-64 (AWG 14/16)
P/N: P1015-14 (AWG 18/22)
• Quick connect to screw adaptor:
P/N: P1015-18
Features:
Fixed ash rate 75 FPM
Custom ash rate 45 - 150 FPM
1 or 2A output
24 or 120VAC
Small size: 1.5 x 0.94 in. (38 x 23.9 mm)
Approvals:
Technical Data
Operation ....................... OFF/ON solid-state asher (continuous duty)
Flash Rate ....................... Factory xed at 75 FPM ±20%
Custom Flash Rates Available ...... From 45 - 150 FPM ±20%
ON/OFF Ratio ................... 50%
Input
Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . 24, 120VAC, ±15%
AC Line Frequency ............... 50/60Hz
Output
Output .......................... Fullwave AC or Halfwave rectied AC
Load Type ....................... Incandescent, resistive, or inductive
(Choose RC sufx for inductive loads)
Maximum Load Rating ............ Fullwave: 1A steady state
Halfwave: 2A steady state
Inrush. . . . . . . . . . . . . . . . . . . . . . . . . . . 10A
Mechanical
Mounting ....................... Removable mounting bracket, use one #8 (M4 x 0.7) screw
Connection/Wires ................ 18 AWG (0.82mm
2
) wires 6 in. (15.2cm)
Dimensions ...................... 1.5 x 0.94 in. (38.1 x 23.9 mm)
Protection
Circuitry ........................ Encapsulated
Environmental
Operating / Storage Temperature .. -20° to 60°C / -40° to 85°C
Humidity ........................ 95% relative, non-condensing
Weight .......................... 1.1 oz (31 g)
Available Models:
Specications
FS126
FS126-45
FS126-60
FS126RC
FS126RC-90
FS127
FS146
FS146RC
The FSU1000 incorporates an onboard adjustable
ash rate of 10 to 100 FPM and a universal input
voltage in one device. Its circuitry is encapsulated
and is capable of controlling loads of up to 20A.
The versatility of the FSU1000 makes it ideal
for applications where various ash rates and
operating voltages are required.
Operation
When input voltage is applied to terminal 2 and the load
(lamp), the load energizes steadily. When input voltage
is applied to terminal 3, the output ashes.
Optional Low Current Switch (S1)
This low current switch could be a limit switch or contact.
While open, the operator sees the load (lamp) ON and
operating. When the limit switch closes, the load (lamp)
ashes to attract attention.
For more information see:
Appendix A, page 164 for Flasher (NC) function.
Appendix B, page 165, Figure 4 for dimensional drawing.
Appendix C, page 168, Figure 1 for connection diagram.
Rating
1A
6A
10A
20A
Inrush Rating
10A
60A
100A
200A
Part Number
FSU1000
FSU1003
FSU1004
FSU1005
Order Table:
Input
120VAC
120VAC
120VAC
24VAC
24VAC
24VAC
Output Rating
1A
1A
2A
1A
1A
2A
Output Type
AC, Fullwave
AC, Fullwave
AC, Halfwave
AC, Fullwave
AC, Fullwave
AC, Halfwave
Load Type*
A
B
A
A
B
A
Part Number
FS126
FS126RC
FS127
FS146
FS146RC
FS147
*Load Type:
A-Incandescent & Resistive
B-Incandescent, Resistive & Inductive
Order Table:
The FS100 Series (low amp) may be used to control
inductive, incandescent or resistive loads. This
series offers a 1A (fullwave) or a 2A (halfwave)
steady state, 10A inrush solid-state output and
may be ordered with an input voltage of 24 or
120VAC. The FS100 Series offers a factory xed
ash rate of 75 FPM or may be ordered with a xed,
custom ash rate ranging from 45 to 150 FPM.
Ideal for OEM applications where cost is a factor.
Operation
Upon application of input voltage, the T2 OFF time
begins. At the end of the OFF time, the T1 ON time begins
and the load energizes. At the end of T1, T2 begins and
the load de-energizes. This cycle repeats until input
voltage is removed.
Reset: Removing input voltage resets the output and the
sequence to T2.
For more information see:
Appendix A, page 164 for Flasher (OFF First) function.
Appendix B, page 165, Figure 12 for dimensional drawing.
Appendix C, page 168, Figure 2 for connection diagram.
Add the sufx “-##” to any part number to
indicate the custom ash rate.

Summary of content (4 pages)