User's Guide

9
8
Cable Guide Mount installation
BB Cup Mount InstallatIon
BB Cup Mount InstallatIon
The BB Cup Mount is only compatible with threaded bottom brackets. It does not work with frames that
have bearings pressed into the bottom bracket (BB30, PF30, etc.). Frames using threaded bottom bracket
adapters (ie. SRAM GXP30 BB Adapter) may use the BB Cup Mount if the mount is installed onto the
threaded drive side bottom bracket cup.
1. If necessary, remove the existing cranks and bottom bracket.
2. Slide the BB Cup Mount over the threads of the drive side bearing cup with the magnet facing away
from the frame.
3. Hold the magnet at the 9 o’clock position while the bottom bracket is tightened to the manufacturer’s
recommended torque.
4. Conrm the magnet is within 2-8 mm (1/16”-3/8”) of the sensor.
2-8 mm
(1/16”-3/8”)
CaBle guIde Mount InstallatIon
The Cable Guide Mount should only be used when the cable guide is fastened with a screw. If the cable
guide is fastened with a rivet, use the Bottom Bracket Cup Mount or Adhesive Putty instead.
Installation Notes: Do not allow the magnet to contact the power meter. When properly installed, the
magnet should be in line with the cadence sensors and within 2-8 mm (1/16”-3/8”) of the sensors.
1. Remove the existing cranks.
2. Loosen the cable guide screw. It may be helpful to shift the front derailleur to the small chainring
position, and the rear derailleur to the smallest cog. This will reduce the cable tension, and make it
easier to slide the cable guide mount under the cable guide.
3. Slide the mount under the cable guide.
4. Reinstall the cranks.
5. Tighten the cable guide screw.
6. Conrm the magnet is within 2-8 mm (1/16”-3/8”) of the sensor.
2-8 mm
(1/16”-3/8”)