Brochure

57
5 5
Limit switches
OsiSense XC
General
Contact blocks (continued)
Contact connections
XE2pP screw clamp terminal connections
b Tightening torque:
v minimum tightening torque ensuring the nominal characteristics of the contact: 0.8 N.m,
v maximum tightening torque without damage to the terminals: 1.2 N.m for XE2pP, 1 N.m for
XE3pP.
b Connecting cable: cable preparation lengths:
v for XE2pP, L = 22 mm,
v for XE2pP3ppp, L = 45 mm,
XE3pP screw clamp terminal connections
v for XE3pP, L = 14 mm, L1 = 11 mm.
Mounting
Sweep of connecting cable
1 Recommended
2 To be avoided
12
Position of cable gland
1 Recommended
2 To be avoided
12
Type of cam
1 Recommended
2 To be avoided
30
30
12
Mounting and xing limit switches by the head
1 Recommended
2 Forbidden
XCKD, XCKP, XCKT, XCMD and XCMN
Contact blocks (continued),
mounting
L
L
L1
12
2