- Limit switches OsiSense XC Special
- Contents
47
5 5
Miniature snap switches
OsiSense XC Special
Subminiature design, DIN 41635 B format, sealed
Sub-subminiature design, DIN 41635 D format
Switch type XEP4E1pp,
XEP5P1W2
XEP4E1ppA326,
XEP5P1W2Z55B
XEP4E1ppA454
Plunger Flat lever Roller lever
Environment characteristics
Lever xing position (1) – A A
Switch actuation On end Horizontal
Product certications e, IEC 60947-5-1, EN 60947-5-1, c UR us, UL 1054, EN 61058
Degree of protection IP 67 XEP4E1FDpp, case IP 67 and tags IP 00 XEP4E1W7pp, case IP 40 and tags IP 00
XEP5P1W2pp
Operating temperature - 40...+ 105°C XEP4E1FDpp, - 40...+ 125°C XEP4E1Wpppp and XEP5P1ppp
Materials Case Polyester XEP4, diallyl-phtalate XEP5
Lever – Stainless steel Stainless steel, glass reinforced
polyamide roller
Contact AgCdO XEP4E1pp, Ag XEP5
Tags Tinned brass XEP4E1Wppp, gold plated brass XEP5P1pp
Mechanical characteristics
Lever xing
position (1)
Maximum tripping force XEP4 A 2.5 N 0.63 N 0.83 N
B 2.5 N 1.25 N 1.67 N
XEP5 2 N 0.80 N –
Minimum release force XEP4 A 0.80 N 0.20 N 0.27 N
B 0.80 N 0.40 N 0.53 N
XEP5 0.40 N 0.15 N –
Maximum permissible
end of travel force
XEP4 A 10 N 2.5 N 3.33 N
B 10 N 5 N 6.67 N
XEP5 10 N – –
Tripping point (TP) (2) XEP4 A 8.40
+/- 0.3
mm 10.7
+/- 1.7
mm 15.5
+/- 1.4
mm
B 8.40
+/- 0.3
mm 9.6
+/- 1.0
mm 14.5
+/- 0.9
mm
XEP5 8.40 mm 9.20 mm –
Maximum differential travel XEP4 A 0.13 mm 0.52 mm 0.39 mm
B 0.13 mm 0.26 mm 0.20 mm
XEP5 0.06 mm 0.25 mm –
Minimum overtravel XEP4 A 0.60 mm 2.40 mm 1.80 mm
B 0.60 mm 1.20 mm 0.90 mm
XEP5 0.10 mm – –
Inter-contact distance XEP4 0.4 mm
XEP5 0.3 mm
Mechanical durability XEP4 2 million operating cycles
XEP5 0.1 million operating cycles
Electrical characteristics
Operational characteristics XEP4 AC-15: B300 (Ue: 240 V, Ie: 1.5 A)
DC-13: R300 (Ue: 250 V, Ie: 0.1 A) conforming to IEC 60947-5-1, EN 60947-5-1 Appendix A
125-250 V AC 6.0 A conforming to UL 1054
6 (1) A 250 V AC 10 000 cycles conforming to EN 61058
XEP5 AC-15: D300 (Ue: 240 V, Ie: 0.3 A) conforming to IEC 60947-5-1, EN 60947-5-1 Appendix A
Thermal current XEP4 7.5 A on 250 V (50/60 Hz)
XEP5 8.5 A on 250 V (50/60 Hz)
Connection XEP4 XEP4E1W7p: 2.8 mm clip tags
XEP4E1FD: Pre-cabled (horizontally in-line), 3 x 0.5 mm
2
, length 0.5 m
XEP5 Solder tags
Operating curves
XEP4E1pp XEP5P1pp
(1) Miniature snap switches tted with a lever are supplied with the lever xed in position A (see page 46). For basic (plunger) snap switches, it is possible to x the
lever in position A or B, depending on the required tripping conditions (see page 46).
(2) Position of the operator in relation to the switch xings (xing hole centre line) at the instant the switch contact changes state.
Characteristics
10
3
10
4
2
2
10
5
2
0,1 0,2 0,5 12 51016A
5
5
1
2
106
Current
1 Resistive circuit
2 Inductive circuit
Cos j 0.8
Number of cycles
250 V a
0,05 0,1 0,2 0,5
12 510A
2x10
10
10
10
6
5
4
6
Number of cycles
Current
250 V a: