Brochure

27
5 5
Limit switches
OsiSense XC Special
For material handling applications, XC1AC
Environment characteristics
Conformity to standards IEC/EN 60947-5-1, IEC 60337-1, VDE 0660-200, CSA C22-2 n° 14
Product certications Special version CSA 600 V (ac) HD
Protective treatment Version Standard: “TC”. Special: “TH”
Ambient air temperature For operation - 25…+ 70°C
For storage - 40…+ 70°C
Operating position All positions
Vibration resistance 9 gn (10…500 Hz) conforming to IEC 60068-2-6
Shock resistance 95 gn (11 ms) conforming to IEC 60068-2-27
Electric shock protection Class I conforming to IEC 60536 and NF C 20-030
Degree of protection IP 65 conforming to IEC 60529 and NF C 20-010
Mechanical durability 10 million operating cycles
Cable entry 3 tapped entries for 13 cable gland
Contact block characteristics
Conventional thermal current 10 A
Rated insulation voltage Slow break contact blocks 500 V a and 600 V c conforming to IEC 60947-5-1, NF C 20-040
a and 600 V c conforming to CSA C22-2 n° 14
Resistance across terminals
y 8 mW
Minimum tripping force XC1AC1p1: 33 N, XC1AC1p6: 23 N, XC1AC1p7: 29 N
Terminal referencing Conforming to CENELEC EN 50013
Short-circuit protection 10 A cartridge fuse type gG (gl)
Electrical durability
b Conforming to IEC 60947-5-1 Appendix C
b Utilisation categories AC-15 and DC-13
b Maximum operating rate: 3600 operating cycles/hour
b Load factor: 0.5
Slow break contact blocks
AC supply
50/60 Hz a
inductive circuit
Power broken in VA
Voltage V
48
110
230
For 1 million operating cycles 450 900 1900
For 3 million operating cycles 170 350 430
DC supply c
inductive circuit
Power broken in W
Voltage V
48
110
230
For 1 million operating cycles 100 100 95
For 3 million operating cycles 35 40 33
General characteristics