Technical Data Bulletin
© 2019 Schneider Electric
All Rights Reserved
2-7
schneider-electric.us
Ring and Ringless Devices
MP Meter-Pak™ Meter Centers
Class 4141 / Refer to Catalog 4100CT0701
Tenant Circuit Breakers
QOM2200MVH
QO2100VH
2P, Plug-on Type
Circuit Breaker
QDP22200TM
2P, Plug-on Type
Circuit Breaker
UL Listed Short Circuit Current Rating depends on lowest interrupting rating of circuit
breaker installed. (Refer to page 2-11 for Square D certified ratings for downstream
panelboards and load centers.)
Table 2.12: Tenant Circuit Breakers
Amperes
10 k AIR
120/240 Vac
22 k AIR
120/240 Vac
42 k AIR
120/240 Vac
100 k AIR
120/240 Vac
For use in 125 A Max. Type MP, MPR and MPH Meter-Pak Metering Equipment
40
QO240
QO240VH [7]
QOH240
—
50
QO250
QO250VH [7] QOH250 [7]
—
60
QO260 QO260VH
QOH260 [7]
—
70
QO270 QO270VH
QOH270 [7]
—
80
QO280 QO280VH
QOH280 [7]
—
90
QO290 QO290VH QOH290
—
100
QO2100 QO2100VH QOH2100
—
125
QO2125 QO2125VH QOH2125
—
For use in 200 A Max. Type MP, MPR and MPH Meter-Pak Metering Equipment
100
QOM2100MM QOM2100MVH
— —
125
QOM2125MM QOM2125MVH
— —
150
QOM2150MM QOM2150MVH
— —
175
QOM2175MM QOM2175MVH
— —
200
QOM2200MM QOM2200MVH
— —
Amperes
10 k AIR
120/240 Vac
25 k AIR
120/240 Vac
65 k AIR
120/240 Vac
100 k AIR
120/240 Vac
For use in 225 A MPL Lever Bypass Meter-Pak Metering Equipment
40
QO240 [8] QO240VH [7] [9] [8] QOH240 [10] [8]
—
50
QO250 [8] QO250VH [7] [9] [8] QOH250 [10] [7] [8]
—
60
QO260 [8] QO260VH [7] [9][8] QOH260 [10] [7] [8]
—
70
QBP22070TM QDP22070TM QGP22070TM QJP22070TM
80
QBP22080TM QDP22080TM QGP22080TM QJP22080TM
90
QBP22090TM QDP22090TM QGP22090TM QJP22090TM
100
QBP22100TM QDP22100TM QGP22100TM QJP22100TM
110
QBP22110TM QDP22110TM QGP22110TM QJP22110TM
125
QBP22125TM QDP22125TM QGP22125TM QJP22125TM
150
QBP22150TM QDP22150TM QGP22150TM QJP22150TM
175
QBP22175TM QDP22175TM QGP22175TM QJP22175TM
200
QBP22200TM QDP22200TM QGP22200TM QJP22200TM
225
QBP22225TM QDP22225TM QGP22225TM QJP22225TM
Accessories for MP Meter-Pak Meter Centers
MMLK500
Table 2.13: Accessories
Accessory Description
Cat. No.
Fifth Jaw Kit Fifth Jaw Kit 5J
Horn Bypass Kit For MPR and MPH only
MMHB
QO Adapter For Bolt-on Q2M tenant circuit breakers (40–125 A, 2P)
EZM125QOA
Slider Type Manual
Circuit Closing:
125 A Ring Style 2 Position Top Meter (Only)
125 and 200 A Ring Style
MM125MB [11]
MM200MB [11]
Sealing Rings:
Snap-on Aluminum
Screw Type Aluminum
Snap-on Type Stainless Steel
2920910001
29008W
ARP00026
Meter Cover-
Lexan
™
Meter Cover-Lexan
™
29007
Optional Lug Kits:
(1) 1/0–600 AWG/kcmil or
(2) 1/0–250 AWG/kcmil per phase
MMLK250 [12][13]
(2) 3/0–500 AWG/kcmil per phase
(2) 2–600 AWG/kcmil per phase
MMLK500 [13]
MMLK600 [13]
Semiflush Kits:
125 A 2 Position
125 A 3–4 Position
125 A 5–6 Position
200 A 2–3 Position
200 A 4 Position
200 A 5–6 Position
MPSF12
MPSF14
MPSF16
MPSF23
MPSF24
MPSF26
NEMA/EUSERC
Lug Landing Kit:
For 3 through 6 position 125 A and 200 A devices. Each pad rated
600 A maximum and includes (2) 1/2-13 studs and mounting
hardware.
MMSK2 [13]
NEMA Lug Landing
Kit:
For use ONLY on MPL43225, MPL53225 and MPL64225 with
optional lugs. See wiring diagram of each device for optional lugs.
MMSK4
MP Meter-Pak
Wireway:
(Wall Mount
Pedestal)
125 A 2 Position ONLY
125 A 3–6 Position
200 A 2–6 Position
MPL32-225
MPL53-225
MPL64-225
MP43X8PED
MP43X11PED
MP43X11PED
MP35X11PED [14]
MP43X11PED
MP35X11PED [14]
MP Meter-Pak
Wireway
Extensions:
Used ONLY with MP43X8PED
Used with MP43X11PED and MP35X11PED
MP12X8PEDEXT [14]
MP12X11PEDEXT
[14]
2
METERING EQUIPMENT
[7] Order only. Not stocked in PDS. Order Point: Lincoln.
[8] Requires use of EZM125QOA adapter (order separately).
[9] QO-VH tenant circuit breakers are rated 22 kAIR at 120/240 Vac.
[10] QOH tenant circuit breakers are rated 42 k AIR at 120/240 Vac.
[11] The meter center short circuit current rating is 10 kA when manual circuit closing is used. Not rated for continuous duty.
[12] Standard lug for 3 through 6 position 125 A and 2 through 4 position 200 A devices.
[13] Cannot be installed on 2 position 125 A device.
[14] Order only. Not stocked in PDS. Order point: Lexington.
For hubs and closing plates, see page 2-3.
5/15/2019