Technical Data Bulletin

© 2019 Schneider Electric
All Rights Reserved
2-13
schneider-electric.us
1 Phase Main Devices
EZ Meter-Pak™ Meter Centers
Class 4161 / Refer to Catalog 4100CT0701
Table 2.18: Main Devices, EUSERC
Ampere
Rating
Service
Feed
Horizontal Cross
Bus Rating and
Bus Bar Material
Cat. No.
Width
(in.)
Factory-Installed Lug Landings for use
with Crimp-Type Lugs (2-Hole
Mounting) Qty. per Phase and Neutral,
except non-EUSERC. [15]
EZM11200GCBE
Main Circuit Breakers (1Ø Incoming and Outgoing)[15]
65 kA 100 kA
 400 UG
400 A, Al
EZM1400CBU [16]
20.46
1 (Order Lugs Separately)
 600 UG
600 A, Al
EZM1600CBU [16]
26.19
2 (Order Lugs Separately)
 800 UG
800 A, Al
EZM1800CBU[16]
26.19
2 (Order Lugs Separately)
1000 UG
1200 A, Cu
EZM11000CBU[17]
34.19
2 (Order Lugs Separately)
1200 UG
1200 A, Al
EZM11200GCBE [18] EZM11200JCBE [18]
32.39
3 (Order Lugs Separately)
Main Fusible Switches (1Ø Incoming and Outgoing) [15] Requires 300 Vac Class T Fuses (Order Separately)
 400 UG
400 A, Al
EZM1400FSU 20.46
1 (Order Lugs Separately)
 600 UG
600 A, Al
EZM1600FSE 18.36
2 (Order Lugs Separately)
 800 UG
800 A, Al
EZM1800FSE 18.36
2 (Order Lugs Separately)
1200 UG
1200 A, Al
EZM11200FSE 32.39
3 (Order Lugs Separately)
Main Lug Terminal Boxes (1Ø Incoming and Outgoing)
 400 UG
800 A, Al
EZM1400TBU [19]
17.16
1 (Order Lugs Separately)
 800 UG
800 A, Al
EZM1800TBU [19]
25.16
2 (Order Lugs Separately)
1200 UG
1200 A, Al/Cu
EZM11200TBU [19]
33.16
3 (Order Lugs Separately)
Main Circuit Breaker (1Ø Incoming and Outgoing) with Energy Reduction Maintenance Switch (ERMS)
1200 UG
1200 A, Al
EZM11200GCBEMS EZM11200JCBEMS 32.39
3 (Order Lugs Separately)
2
METERING EQUIPMENT
[15] For mechanical lugs (3/0 AWG– 600 kcmil) order kit CMELK4. Kit includes 4 lugs only. Multiple kits may be required, consult factory. For crimp-type lugs refer to Anderson Electrical
Connector Products Catalog AEC-40R.
[16] Available by special order with main circuit breaker supplied with other standard ampere ratings, consult local Field Office (allow 6 weeks for delivery).
[17] Supplied with copper horizontal bus bars and aluminum vertical bus bars.
[18] Ampere rating of the circuit breaker supplied with this device can be changed to a LOWER value in the field by changing the setting on the circuit breaker.
[19] Terminal box is suitable for use on LINE or LOAD side of service equipment. Supplied with isolated neutral and provided with neutral bonding kit for use as required. Refer to page 2-11 for
appropriate short circuit current ratings.
5/15/2019