Removal of Twistouts
1. Remove only those twistouts to match circuit breakers by twisting
out with pliers at center of twistout.
NOTE: Remove only one side when installing Q1 circuit breakers.
2. Close all unused open spaces in trim by ordering one of the
following filler plates:
— Catalog No. QOFP for spaces measuring 0.75 x 2.31 inches.
— Catalog No. QO1FP for spaces measuring 0.75 x 2.44 inches.
3. Remove only the twistouts necessary to match circuit breakers, by
rapping sharply with screwdriver at extreme corner away from tie.
4. For 2- and 3-pole circuit breakers, remove divider between
twistouts with pliers.
NOTE: Remove only one side when using Q1 circuit breakers.
5. Close all unused open spaces in trim by ordering filler plate
Catalog No. QOFP.