Technical Data Bulletin

7-72
© 2020 Schneider Electric
All Rights Reserved
12/2/2020
MasterPact™ Power Circuit Breakers MasterPact™ MTZ Circuit Breakers
www.se.com/us
Class 0614 / Refer to Catalog 0614CT1701
Table 7.144 Secondary Terminal Block Kits (cont'd.)
Fixed MTZ1/2/3 Drawout MTZ1 Drawout MTZ2/3
Ring Tongue Kit 1b MTZ2-3
LV839297SP
Ring Tongue Kit 1a & 1b MTZ2-3
LV839298SP
Table 7.145: Accessories for MicroLogic X Control Units
Catalog Number
External power
supply module (AD)
24–30 Vdc LV454440
48–60 Vdc LV454441
100–125 Vdc LV454442
110–130 Vdc LV454443
200–240 Vdc LV454444
Interlocks Catalog Numbers
Description Catalog Number
Door Interlock
Door interlock MTZ1
Right and left-hand side of cradle (VPECD or VPECG)
LV833172SP
Door interlock MTZ2/3
Right and left-hand side of cradle (VPECD or VPECG)
LV847914SP
Cable-type door interlock 1 complete assembly for MasterPact MTZ2/MTZ3 fixed or drawout device
LV848614SP
Mechanical Interlocking for Source Changeover for MTZ2/3
Interlocking of 2 devices using connecting rods
Choose 1 set of 2 adaptation fixtures (1 for each device) + 1
set of rods
Rod Interlock kit: 1 set of 2 adaptation fixtures for MasterPact MTZ2 or MTZ3 fixed or drawout
device
LV847930SP
1 set of 2 interlocking rods
LV833210SP
Can be used with 1 MTZ2/3 fixed + 1 MTZ2/3 drawout. Note: the installation manual is enclosed. Interlocking of 2 devices using
cables [1]
Interlocking of 2 devices using cables [1]
Choose 2 adaptation sets (1 for each device + 1 set of cables)
1 adaptation fixture for MasterPact MTZ2/3 fixed devices
LV847926SP
Cable mouinting plate: 1 adaptation fixture for MasterPact MTZ2/3 drawout devices
LV847926SP
Cable interlock: 1 set of 2 cables LV833209SP
Interlocking of 3 devices using cables
Choose 3 adaptation (including 3 adaptation fixtures + cables)
3 sources, only 1 device closed, fixed or drawout devices
LV848610SP
2 sources + 1 coupling, fixed or drawout devices
LV848609SP
2 normal + 1 replacement source, fixed or drawout devices
LV848608SP
Neutral Sensors Catalog Numbers
External Sensor for Neutral Ground-Fault Protection (TCE)
External Sensor for
Source Ground-Return Protection
S1
LV848891S
P
Replaces
S48891
4889
1
Modified Different
ia
l
Ground Fault Inter
f
a
c
e
Module
Mód
u
lo de
interfaz de falla a
tierra diferenc
ia
l
modif
i
ca
da
Module d'inter
a
c
e
d
e d
é
faut à la terre
différentiel
modifié
MDGF
Table 7.146: Neutral Sensor Parts
Catalog Number
Neutral Sensor Wiring Harness for MTZ1/2
LV848907SP
Neutral Sensor Wiring Harness for MTZ3
LV848906SP
MDGF/SGR (Source Ground
Return) Sensor plug
External sensor (SGR)[8]
LV833579SP
MDGF summing module for MTZ2/3
LV848891SP
Table 7.147: MasterPact MTZ1 External Neutral Sensors
Used With
Sensor Plug
External Neutral Sensor
For General Use
Circuit breakers with standard neutral protection
400–1600 A LV833576SP
Circuit breakers with oversized neutral protection[9]
400–1000 A LV833576SP
1200–1250A LV834035SP
1600A LV834036SP
Table 7.148: MasterPact MTZ2/MTZ3 External Neutral Sensors
Description
External Neutral Sensor
For Residual Ground
Fault
For 3P Circuit Breaker with Oversized
Neutral Protection[10]
MasterPact MTZ2 Circuit Breakers
Sensor Plug
400
LV834037SP
LV834037SP
600–630
800
1000
1200–1250 LV834035SP
1600
LV834036SP2000 LV834035SP
2500
LV834036SP
3000
3200
4000
MasterPact MTZ3 Circuit Breakers
Sensor Plug
Kit includes qty. (2)
neutral sensors
2000
LV848182SP
LV848182SP
2500
3000
3200
4000
5000
6000
6300
Cradle Metering CT Kit Catalog Numbers
For use with UL and ANSI rated circuit breakers only.
Not available with ArcBlok Technology.
7
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
[8] Four MDGF sensors (phase + 1 neutral) are required for MTZ2; eight MDGF sensors are required for MTZ3. For SGR system only one sensor (neutral) is required for MTZ2; two sensors for
MTZ3
[9] Oversized neutral protection = 1.6 Ir where Ir = long time pick-up
[10] Oversized neutral protection = 1.6 Ir where Ir = long time pick-up.