Technical Data Bulletin
Table Of Contents
- Section 7 Miniature and Molded Case Circuit Breakers
- Selection Information
- QO™ and QOU Miniature Circuit Breakers
- Homeline™ Miniature Circuit Breakers
- Multi 9™ Miniature Circuit Breakers
- PowerPact™ Molded Case Circuit Breakers
- Mission Critical Circuit Breakers
- 500 Vdc Circuit Breakers
- Automatic Switches
- Motor Circuit Protectors
- PowerPact™ Circuit Breaker Accessories
- MicroLogic™ Electronic Trip Units
- MasterPact™ Power Circuit Breakers
- Enerlin’X Digital Solutions
- Ground-Fault Protection
- Dimensions and Shipping Weights
- Circuit Breaker Enclosures
7-64
© 2020 Schneider Electric
All Rights Reserved
12/2/2020
MicroLogic™ Electronic Trip Units MicroLogic™ Trip Unit Accessories
www.se.com/us
Class 612, 612 / Refer to Catalogs 0611CT1001 and 0612CT0101
Trip Unit Accessories
Trip Unit Seal
Sensor Plug
Table 7.128: Rating Plugs
Rating Plug
[7]
Factory Installed
Cat. Suffix
Field-Installable
Cat. No.
A
A (standard)
S48818
B B S48819
C C S48820
D D S48836
E E S48837
F F S48838
G G S48839
H H S48840
Adjustable rating plug "A" is installed as standard on all MicroLogic trip unit orders.
However, an alternative selection may be specified from the "Assembled" table below,
and factory installed with your trip unit order at no additional charge. To order, please
attach the appropriate catalog suffix to the end of the trip unit Cat. No. (after specifying
trip unit options). Adjustable rating plugs may also be purchased as field-installable
components from the table below.
For Enerlin’X accessory information, see Enerlin’X Digital Solutions, page 7-78
Table 7.129: Neutral Current Transformers
Use With Cat. No. Sensor
H-Frame
S429521 60–100
S430562 150
J-Frame S430563 250
L-Frame S432575 400–600
P-Frame
S33575 [8]
250
S33576 [8]
400–1600
R-Frame
S48916 [8]
250
S34036 [8]
400–1600
S48896 [8]
2000
S48182 [8]
3000
All NCTWIRING All
Table 7.130: Zone-Selective Interlocking
Description
Factory-Installed
Cat. Suffix
Field-Installable
Cat. No.
ZSI Interface Module — S434212
24 Vdc Terminal Block EN S434210
ZSI Wire Harness, H/J
Frame
YH3 S434300
ZSI Wire Harness, L-Frame
YH3 S434301
ENCT & ZSI Wire Harness YH4 —
Table 7.131: Trip Unit Accessories
Device Frame Cat. No.
Pocket Tester
H/J/L
S434206
UTA Tester STRV00910
Spare UTA Tester
STRV00911
Bluetooth/Modbus for UTA Tester SVW3A8114
Spare Power Supply for UTA Tester (110–120 Vac)
TRV00915
MicroLogic Cord for UTA Tester
TRV00917
MicroLogic 5/6 Cover, Transparent
H/J
S429478
MicroLogic 2/3 Cover, Transparent
S429481
MicroLogic 5/6 Cover, Transparent
L
S432459
MicroLogic 2/3 Cover, Transparent
S432461
LCD Display for MicroLogic 5
H/J/L
S429483
LCD Display for MicroLogic 6
S429484
Hand-held Test Kit
P/R
S33594
Primary Injection Test Adaptor
S33937
Full-function Adapter Kit
S48981
Full-function Test Kit S33595
Seven-pin Test Cable (for connection between test kit and trip unit) [9]
S48907
Two-pin Test Cable (for connection between test kit and trip unit) [10]
S48908
M2CTEST (for isolated trip unit testing) [11]
M2CTEST
230 Vac Filtered Power Cord [12]
P/R
S48856
120 Vac Filtered Power Cord [12]
S48855
Trip Unit Battery for Trip Indicator Lights
S33593
Power supply with:
24–30 Vdc input
LV454440
48/60 Vdc input
LV454441
125 Vdc input
LV454442
110–130 Vac input
LV454443
200–240 Vac input
LV454444
MicroLogic A Trip Unit Cover, clear
P/R
S33592
MicroLogic P/H Trip Unit Cover, opaque gray
S47067
Trip Unit Seal (6 pieces) for compliance with NEC 240.6(c)
H/J/L/P/R MICROTUSEAL
12-pin Trip Unit Connector for NT/NW MasterPact Circuit Breakers
P/R
S33101
12-pin Trip Unit Connector for P- and R-Frame Circuit Breakers
S33100
Battery Back-up (12 Hours)
685831
Table 7.132: Sensor Plugs for P- and R-Frame Circuit Breakers [13]
Description Sensor Plug Range Sensor Plug Cat. No. Circuit Breaker Frames Accepting Sensor Plug
P-Frame Circuit Breaker 250 A 400 A 600 A
630 A [14]
800 A 1000 A 1200 A
1250 A
[14]
1600 A
UL
250 A S47052 X — — — — — — — —
400 A S47053 — X X — X — — — —
600 A S48823 — — X — X X X — —
800 A S33092 — — — — X X X — —
1000 A S33093 — — — — — X X — —
1200 A S48824 — — — — — — X — —
IEC
630 A S33091 — — — X X X — X X
800 A S33092 — — — — X X — X X
1000 A S33093 — — — — — X — X X
1250 A S33094 — — — — — — — X X
1600 A S33095 — — — — — — — — X
R-Frame Circuit Breaker 600 A 800 A 1000 A 1200 A 1600 A 2000 A 2500 A 3000 A 3200 A
UL
600 A S48823 X X X X — — — — —
800 A S33092 — X X X X — — — —
1000 A S33093 — — X X X X — — —
1200 A S48824 — — — X X X X — —
1600 A S33095 — — — — X X X X —
2000 A S33982 — — — — — X X X —
2500 A S33983 — — — — — — X X —
3000 A S48825 — — — — — — — X —
IEC
1600 A S33095 — — — — X X X X X
2000 A S33982 — — — — — X X X X
2500 A S33983 — — — — — — X X X
3200 A S33984 — — — — — — — — X
7
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
[7] Long-time pickup amperes (Ir) = Sensor Rating (In) X Setting of rating plug. “Fine adjustment tuning” is included on MicroLogic Power and Harmonic trip units, allowing for incremental
settings of 1 A between the plug setting and.40 X Sensor Rating.
[8] Includes NCTWIRING kit.
[9] Used for testing MicroLogic trip units. Included in the price of the Hand-held/Full-function Test Kits. Kit for replacement only.
[10] Used for testing STR trip units. Included in the price of the Hand-held/Full-function Test Kits. Kit for replacement only.
[11] Required for Arc Energy Reduction Performance Testing for Instantaneous setting or Maintenance Mode Switch when using a Full Function Test Kit
[12] Included with the Full-function Test Kit. Kit for replacement only.
[13] For use only with circuit breakers with date codes later than 07011. For long-time pickup range, See rating plug information at page 7-61.
[14] IEC Only.