www.se.com/us
H- and J-Frame Circuit Breakers PowerPact™ Molded Case Circuit Breakers
Class 611 / Refer to Catalog 0611CT1001
PowerPact H- and J-Frame Electronic Trip Current Limiting Circuit
Breakers (150 A and 250 A)
H-Frame
MicroLogic™ Trip Unit
J-Frame
MicroLogic Trip Unit
rciM cigolo
E
2
.5
rI
%
A
0
3
>
0
3
>
01
1>
.9
2
9
.
3
9
.
49.
5
9.
1
89.
7
9
.
6
9
.
Ir
)
o
Ix
(
5.
1
2
5
.
2
3
4
0
1
8
6
5
d
s
I )r
Ix
(
H-Frame Circuit Breaker
Optional FDM and IFM Module
Table 7.58: H-Frame 150 A and J-Frame 250 A Electronic Trip UL Current-Limiting [13] Standard (80% Rated) Circuit Breakers (600 Vac)
With Factory Sealed Trip Unit
[14] Suitable for Reverse Connection [15]
Electronic Trip Unit
Sensor
Rating
Interrupting Rating (80% Rated)
Type
Function
Trip Unit
D G
J [13] L [13] R [13]
600 Vac, 50/60 Hz, 3P
MicroLogic
Standard
LI
3.2 [16]
60 A HDL36060U31X HGL36060U31X HJL36060U31X HLL36060U31X HRL36060U31X
100 A HDL36100U31X HGL36100U31X HJL36100U31X HLL36100U31X HRL36100U31X
150 A HDL36150U31X HGL36150U31X HJL36150U31X HLL36150U31X HRL36150U31X
250 A JDL36250U31X JGL36250U31X JJL36250U31X JLL36250U31X JRL36250U31X
MicroLogic
Standard
LSI
3.2S [16]
[17]
60 A HDL36060U33X HGL36060U33X HJL36060U33X HLL36060U33X HRL36060U33X
100 A HDL36100U33X HGL36100U33X HJL36100U33X HLL36100U33X HRL36100U33X
150 A HDL36150U33X HGL36150U33X HJL36150U33X HLL36150U33X HRL36150U33X
250 A JDL36250U33X JGL36250U33X JJL36250U33X JLL36250U33X JRL36250U33X
MicroLogic
Ammeter
LSI 5.2A
60 A HDL36060U43X HGL36060U43X HJL36060U43X HLL36060U43X HRL36060U43X
100 A HDL36100U43X HGL36100U43X HJL36100U43X HLL36100U43X HRL36100U43X
150 A HDL36150U43X HGL36150U43X HJL36150U43X HLL36150U43X HRL36150U43X
250 A JDL36250U43X JGL36250U43X JJL36250U43X JLL36250U43X JRL36250U43X
MicroLogic
Energy
LSI 5.2E
60 A HDL36060U53X HGL36060U53X HJL36060U53X HLL36060U53X HRL36060U53X
100 A HDL36100U53X HGL36100U53X HJL36100U53X HLL36100U53X HRL36100U53X
150 A HDL36150U53X HGL36150U53X HJL36150U53X HLL36150U53X HRL36150U53X
250 A JDL36250U53X JGL36250U53X JJL36250U53X JLL36250U53X JRL36250U53X
MicroLogic
Ammeter
LSIG
6.2A [18]
60 A HDL36060U44X HGL36060U44X HJL36060U44X HLL36060U44X HRL36060U44X
100 A HDL36100U44X HGL36100U44X HJL36100U44X HLL36100U44X HRL36100U44X
150 A HDL36150U44X HGL36150U44X HJL36150U44X HLL36150U44X HRL36150U44X
250 A JDL36250U44X JGL36250U44X JJL36250U44X JLL36250U44X JRL36250U44X
MicroLogic
Energy
LSIG 6.2E
60 A HDL36060U54X HGL36060U54X HJL36060U54X HLL36060U54X HRL36060U54X
100 A HDL36100U54X HGL36100U54X HJL36100U54X HLL36100U54X HRL36100U54X
150 A HDL36150U54X HGL36150U54X HJL36150U54X HLL36150U54X HRL36150U54X
250 A JDL36250U54X JGL36250U54X JJL36250U54X JLL36250U54X JRL36250U54X
Table 7.59: H-Frame 150 A and J-Frame 250 A Electronic Trip UL Current-Limiting [13] 100% Rated Circuit Breakers (600 Vac) With Factory
Sealed Trip Unit
[14] Suitable for Reverse Connection [15]
Electronic Trip Unit
Sensor
Rating
Interrupting Rating (100% Rated)
Type
Function
Trip Unit
D G
J [13] L [13] R [13]
600 Vac, 50/60 Hz, 3P[19]
MicroLogic
Standard
LI
3.2 [16]
60 A HDL36060CU31X HGL36060CU31X HJL36060CU31X HLL36060CU31X HRL36060CU31X
100 A HDL36100CU31X HGL36100CU31X HJL36100CU31X HLL36100CU31X HRL36100CU31X
150 A HDL36150CU31X HGL36150CU31X HJL36150CU31X HLL36150CU31X HRL36150CU31X
250 A JDL36250CU31X JGL36250CU31X JJL36250CU31X JLL36250CU31X JRL36250CU31X
MicroLogic
Standard
LSI
3.2S [16]
[17]
60 A HDL36060CU33X HGL36060CU33X HJL36060CU33X HLL36060CU33X HRL36060CU33X
100 A HDL36100CU33X HGL36100CU33X HJL36100CU33X HLL36100CU33X HRL36100CU33X
150 A HDL36150CU33X HGL36150CU33X HJL36150CU33X HLL36150CU33X HRL36150CU33X
250 A JDL36250CU33X JGL36250CU33X JJL36250CU33X JLL36250CU33X JRL36250CU33X
MicroLogic
Ammeter
LSI 5.2A
60 A HDL36060CU43X HGL36060CU43X HJL36060CU43X HLL36060CU43X HRL36060CU43X
100 A HDL36100CU43X HGL36100CU43X HJL36100CU43X HLL36100CU43X HRL36100CU43X
150 A HDL36150CU43X HGL36150CU43X HJL36150CU43X HLL36150CU43X HRL36150CU43X
250 A JDL36250CU43X JGL36250CU43X JJL36250CU43X JLL36250CU43X JRL36250CU43X
MicroLogic
Energy
LSI 5.2E
60 A HDL36060CU53X HGL36060CU53X HJL36060CU53X HLL36060CU53X HRL36060CU53X
100 A HDL36100CU53X HGL36100CU53X HJL36100CU53X HLL36100CU53X HRL36100CU53X
150 A HDL36150CU53X HGL36150CU53X HJL36150CU53X HLL36150CU53X HRL36150CU53X
250 A JDL36250CU53X JGL36250CU53X JJL36250CU53X JLL36250CU53X JRL36250CU53X
MicroLogic
Ammeter
LSIG
6.2A [18]
60 A HDL36060CU44X HGL36060CU44X HJL36060CU44X HLL36060CU44X HRL36060CU44X
100 A HDL36100CU44X HGL36100CU44X HJL36100CU44X HLL36100CU44X HRL36100CU44X
150 A HDL36150CU44X HGL36150CU44X HJL36150CU44X HLL36150CU44X HRL36150CU44X
250 A JDL36250CU44X JGL36250CU44X JJL36250CU44X JLL36250CU44X JRL36250CU44X
MicroLogic
Energy
LSIG 6.2E
60 A HDL36060CU54X HGL36060CU54X HJL36060CU54X HLL36060CU54X HRL36060CU54X
100 A HDL36100CU54X HGL36100CU54X HJL36100CU54X HLL36100CU54X HRL36100CU54X
150 A HDL36150CU54X HGL36150CU54X HJL36150CU54X HLL36150CU54X HRL36150CU54X
250 A JDL36250CU54X JGL36250CU54X JJL36250CU54X JLL36250CU54X JRL36250CU54X
Accessories see page 7-51
Optional Lugs see page 7-56
Dimensions see page 7-84
Enclosures see page 7-85
7
MINIATURE AND MOLDED CASE
CIRCUIT BREAKERS
[13] Circuit breakers with J, L, and R interrupting ratings are UL certified as current limiting.
[14] See Supplemental Digest Section 3 for circuit breakers with field interchangeable trip units.
[15] For applications requiring communications see page 7-64.
[16] 3P circuit breakers with this trip unit can be used for 2P applications.
[17] Fixed ST and LT delays.
[18] 3P circuit breakers with this trip unit can be used for 2P applications requiring ground fault protection. Additional metering capabilities will not work properly on the unconnected phase.
[19] 3-pole PowerPact H- and J-frame circuit breakers can be used for 2-pole applications. (For such instances, MicroLogic 6.2 Ammeter and Energy trip units can be used for ground fault
protection. Additional metering capabilities are not guaranteed when using MicroLogic Ammeter and Energy trip units for this type of application.