Technical Data Bulletin
Table Of Contents
- Section 1 Load Centers
- EZ Selector - Selection Assistance
- QO™ Miniature Circuit Breakers
- QO™ Load Centers
- Homeline™ Miniature Circuit Breakers
- Homeline™ Load Centers
- QO/Homeline Load Center Value Packs and Accessories
- QO/Homeline Load Center Dimensions
- Combination Service Entrance Devices
- RC/QC Solar Ready CSEDs
- Homeline Solar Ready PoN CSEDs
- Wiser Energy™
- Enclosed Devices
- Servicepak™ Power Outlet Panels
© 2020 Schneider Electric
All Rights Reserved
10/30/2020
1-41
www.se.com/us
Rainproof, Meter Mains and All-In-Ones,
125 to 225 A Maximum
Homeline Solar Ready PoN CSEDs
Class 4120
Homeline Solar Ready PoN CSEDs
•
Ring-type Meter Sockets
•
UL Listed, suitable only for use as service equipment
•
Service disconnect(s) are supplied factory-installed, except
where noted
•
Interiors accept plug-on neutral and pigtail style branch
circuit breakers
•
Supplied with a fully distributed neutral bar, all unused
terminals may be used for equipment grounding wires
•
Meets Ferderal Specification W-P-115c as Type 1, Class 2
•
Solar Ready kit SR69064A fits all devices below
•
All devices have a 3" KO in the bottom endwall
•
Provisions for field installed CTs on All devices
•
Meets EUSERC requirements
Table 1.88: All-In-One Combination Service Entrance Devices
Main
Breaker
Bus Bar
Ampere
Rating
Bypass
Type
Service
Type
Short Circuit
Current
Rating
Cat. No. [1]
Service Disconnect(s)
Load Center and Branch
Circuit Breakers
(Order Separately
Pages 1-2, 1-3, 1-4)
Hub
Type
(Order
Sepa-
rately
[2])
Line
Side
Main
Lugs
AWG/
kcmil
(Al/Cu)
Service
Ground
Lug
AWG/
kcmil
(Al/Cu)
Max. Quantity
Ampere
Rating Max.
Spaces
1P
Circuits
Tandems
2P
Circuits
(Max.)
Type
(Factory Installed
except where
noted)
Semiflush Mount Only
200 A
225 A
None
OH[3]/UG
22 kA
SC816F200PF [4]
1
QOM2200VH
8 16 8 200 A
A-L 4-250 8-2/0
125 A None
OH[3]/UG
22 kA SC2040M125PF 1
QOM2125VH
20 40 20 110 A
200 A
None
OH[3]/UG
22 kA SC2040M200PF 1
QOM2200VH
20 40 20 200 A
None
OH[5]/UG
22 kA SC3042M200PF 1
QOM2200VH
30 42 12 200 A
225 A None
OH[5]/UG
22 kA SC3042M225PF 1
QOM2225VH
30 42 12 200 A
Surface Mount Only
150 A
225 A
None OH/UG 22 kA
SC816F150PS [4]
1
QOM2150VH
8 16 8 150 A
A-L 4-250 8-2/0
200 A
None OH/UG 22 kA
SC816F200PS [4]
1
QOM2200VH
8 16 8 200 A
None OH/UG 22 kA SC2040M200PS 1
QOM2200VH
20 40 20 200 A
None OH/UG 22 kA SC3042M200PS 1
QOM2200VH
30 42 12 200 A
None OH/UG 22 kA SC42M200PS 1
QOM2200VH
42 42 0 200 A
Table 1.89: Knockouts
Symbol
A B C D E F G H I J
Conduit Size
(in.)
1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4
3.40
86
14.85
377
A
A,B
C,D,E
,F
B,C
10
.
30
262
42.60
1006
38.40
899
8/16 - 20/40
30/42
C,E,F,G,H
2
1
/
2
" Max
“A-L” Hub
C,D,E,F
A
B,C
B
Semiflush Mount
2
1
/
2
" Max “A” Hub
29.50
749
5.80
147
21.50
546
C,E,F,G,H
2
1
/
2
" Max
“A-L” Hub
A
B,C
B
C,D,E,F
11.10
282
32.30
820
37. 30
947
SC42M200PS
SC3042M200PS
Surface Mount
1
LOAD CENTERS
[1] Accepts Solar Ready Kit Part Number SR69064A. Check with local utility for approval and order separately.
[2] See Bolt-On Hubs, page 1-31
[3] Suitable for OH service with addition of tunnel kit (SCTKP20). Check with local utility for approval and order separately.
[4] Supplied with load side feed-thru lugs, for 4AWG-250 kcmil Al/Cu conductors.
[5] Suitable for OH service with addition of tunnel kit (SCTKP30). Check with local utility for approval and order separately.