Technical Data Bulletin
Table Of Contents
- Section 1 Load Centers
- EZ Selector - Selection Assistance
- QO™ Miniature Circuit Breakers
- QO™ Load Centers
- Homeline™ Miniature Circuit Breakers
- Homeline™ Load Centers
- QO/Homeline Load Center Value Packs and Accessories
- QO/Homeline Load Center Dimensions
- Combination Service Entrance Devices
- RC/QC Solar Ready CSEDs
- Homeline Solar Ready PoN CSEDs
- Wiser Energy™
- Enclosed Devices
- Servicepak™ Power Outlet Panels
1-36
© 2020 Schneider Electric
All Rights Reserved
10/30/2020
Combination Service Entrance Devices Rainproof, Meter Mains and All-In-Ones,
300–400 A
www.se.com/us
Class 4119, 4120
1
LOAD CENTERS
Meter Mains and All-in-Ones (300–400 A Devices)
Meter Mains and All-in-Ones
•
Ring or ringless type meter socket designs available
•
UL Listed, suitable only for use as service equipment
•
Meets EUSERC standards where indicated.
•
Service disconnects are supplied factory-installed, except where noted
•
Supplied with 100% branch neutrals; all unused terminals may be used for equipment
grounding wires
•
Meets Federal Specification W-P-115c as Type 1, Class 2
Meter Mains: Meets Federal Specification W-P-115c as Type 1, Class 2, UL Listed,
suitable only for use as service equipment, 120/240 Vac, 1Ø3W, NEMA 3R Enclosure
Table 1.79: Meter Mains
Ampere Rating
Bypass Type
Service
(Type
of Feed)
Short Circuit
Current Rating
Cat. No.
Service Disconnect(s) [46]
Load Center and Branch
Circuit Breakers
(Order separately [47])
Hub Type
(Order separately [48])
Line
Side
Main
Lugs
AWG/
kcmil
(Al/
Cu)
Service
Ground
Lug
AWG/
kcmil
(Al/Cu)
Weight
Each
(Lbs)
and
Pallet
Qty.
Max. Quantity
Ampere
Rating Max.
Spaces
1P
Circuits
Tan-
dems
UL
UL and
EU-
SERC
2P
Cir-
cuits
(Max.)
Type
(Order separately
[49])
Ampere
Rating
(Max.)
Ring Type, QO
Surface and Semiflush Mount [46]
400
A
None UG UG 25 kA
CU12L400CN [50]
1
QDL22200 [51]
200 A — — — —
A–L
(2)
Studs
4–250
98, 4
CU12L400FN [50]
1
QDL, QGL, QJL [52]
200 A — — — —
4
QO, QO-VH or QOH
[53]
125 A [54]
— — — —
400
A
Class
320
Manual
Bypass
UG — 25 kA
CU12L400CB [50] [55]
1
QDL22200 [51]
200 A — — — —
A–L
(2)
Studs
4–250
98, 4
CU12L400FB [50] [55]
1
QDL, QGL, QJL [52]
200 A — — — —
4
QO, QO-VH or QOH
[53]
125 A [54]
— — — —
400
A
None UG UG 25 kA
CU816D400CN [50] [56]
1
QDL22200 [51]
200 A 8 16 8 200 A
A–L
(2)
Studs
4–250
98, 4
400
A
Class
320
Manual
Bypass
UG — 25 kA
CU816D400CB [50] [54]
[55]
QDL, QGL, QJL [52]
A–L
(2)
Studs
4–250
98, 4
400
A
Class
320
Manual
Bypass
UG —
65 kA
[46]
CUM400CB [50] [55]
1
LJL36400U31X [51]
400 A —
2 [57]
— 200 A A–L
(2)
Studs
4–250
115, 4
Ringless Type, QO
400
A
Class
320
Lever
UG — 25 kA
QU12L400SL [58] [55]
1
QDL22200 [51]
200 A — — — —
A–L
(2)
Studs
4–250
98, 4
1
QDL, QGL, QJL [52]
200 A — — — —
4
QO, QO-VH or QOH
[53]
125 A [54]
— — — —
Surface Mount Only, Supplied with Feed-Thru Lugs and Provisions for Branch Circuit Breakers
400
A
[59]
UG — 25 kA
QU816D400SL [54] [58]
[55]
QU816D400CK [56] [55]
1
QDL22200 [51]
QDL, QGL, QJL [52]
200 A 8 16 8 200 A A–L
(2)
Studs
4–250
98, 4
Surface and Semiflush Mount [46]
400
A
Class
320
Lever
UG — 25 kA
QU12L400CL [58] [60]
[55]
1
QDL22200 [51]
200 A — — — —
A–L
(2)
Studs
4–250
98, 4
1
QDL, QGL, QJL [52]
200 A — — — —
4
QO, QO-VH or QOH
[53]
125 A [54]
— — — —
400
A
UG — 25 kA
QU816D400CL [58] [54]
[60] [55]
1
QDL22200 [51]
200 A 8 16 8 200 A A–L
(2)
Studs
4–250
98, 4
QU816D400FL [58] [54]
[60] [55]
1
QDL, QGL, QJL [52]
400
A
Class
320
Lever
UG —
65 kA
[46]
QUM400CL [58] [55]
1
LJL36400U31X [51]
400 A —
2 [57]
— 200 A A–L
(2)
Studs
4–250
120, 4
400
A
K-4 Bolt-
On
UG —
65kA
[46]
QUM400CK [50] [55]
1
LJL36400U31X [51]
400 A —
2 [57]
— 200 A A–L
(2)
Studs
4–250
123, 4
None
[46] UL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker installed.
[47] To order branch circuit breakers, see QO Plug-On Circuit Breakers, page 1-3
[48] To order hubs, see Accessories and Hubs for CSEDs, page 1-38
[49] To order service disconnects, see Circuit Breakers for CSEDs, page 1-37 except as noted)
[50] For use only on 120/240 Vac 1Ø3W system (4-jaw meter socket).
[51] Service disconnect supplied factory-installed.
[52] Additional service disconnect for field-installation: order prefix QBL at 10 kA, QDL at 25 kA, QGL at 65 kA, or QJL at 100 kA. Order separately. For complete circuit breaker catalog number,
see Digest Section 7.
[53] Order two pole circuit breakers for field installation: order catalog designation QO for 10 kA, QO-VH for 22 kA or QOH for 42 kA short circuit current rating. See Table 1.1 Plug-On Circuit
Breakers, page 1-3 or Table 1.81 Circuit Breakers for use with Meter Mains and All-In-One Devices, page 1-37.
[54] QO panel is rated 200 A maximum.
[55] Device configuration is not included in EUSERC standards. Consult applicable utility for acceptance.
[56] Supplied with load side feed-thru lugs for 6 AWG–250 kcmil (Al/Cu) conductors.
[57] Option for field installation of two Q-frame, 200 A max. 2-pole branch circuit breakers used as mains for two downstream load centers. Purchase installation kit BMK2Q400 and two Q-frame
circuit breakers separately. Order QBL prefix at 10 kA, QDL prefix at 25 kA, or QGL prefix at 65 kA.
[58] Fifth jaw factory-installed.
[59] Device with suffix L has Class 320 lever bypass and device with suffix K has a K-4 bolt-on, no bypass.
[60] Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Table 1.82 Accessories, page 1-38).