Combination Service Entrance Devices Rainproof, Meter Mains
www.se.com/us
Class 4119, 4120
1
LOAD CENTERS
Table 1.77 Rainproof Meter Mains (cont'd.)
Ampere Rating
Bypass Type
Service
(Type of Feed)
Short Circuit
Current Rating
Cat. No.
Service Disconnect(s)
Load Center and Branch
Circuit Breakers
(Order separately [18])
Hub Type (Order
separately [19])
Line
Side
Main
Lugs
AWG/
kcmil
(Al/
Cu)
Service
Ground
Lug|
AWG/|
kcmil|
(Al/Cu)
Weight
Each
(Lbs)
and
Pallet
Qty.
2P
Circuits
(Max.)
Type
(Order
separately
[20])
Ampere
Rating Max.
Max. Quantity
Ampere
Rating Max.
Spaces
1P
Circuits
Tan-
dems
UL
UL and
EU-
SERC
200 A
None OH/UG — 22 kA
QC816F200S [21] [22]
[23] [24]
1
QOM2200VH
[25]
200 A 8 16 8
200 A
[26]
A 6–350
8–2/0
43, 21
Horn OH/UG — 22 kA
QC816F200SH [21]
[22] [23] [24]
1
QOM2200VH
[25]
200 A 8 16 8
200 A
[26]
A 6–350
Horn OH/UG — 22 kA
QC816F200CH [21]
[22]
1
QOM2200VH
[25]
200 A 8 16 8
200 A
[26]
A 6–350 12-2/0
40, 21
Lever OH/UG — 22 kA
QC816F200SL [21]
[22] [23] [24]
1
QOM2200VH
[25]
200 A 8 16 8 200 A A 6–350 8–2/0 74 / 12
Ringless, Homeline
TM
Surface Mount Only
125 A None OH/UG — 10 kA
RC8L125S[27]
4 HOM
125 A
[28]
— — — — A 6–2/0 6–2/0
27, 32
200 A None OH/UG — 10 kA
RC12L200S [22] [23]
[24]
6 HOM
200 A
[26]
— — — — A 6–350 8–2/0
43, 21
200 A None OH/UG — 22 kA
RC12L200C [22]
6 HOM
200 A
[26]
— — — — A 6–350 12-2/0
40, 21
Surface Mount Only, Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers
100 A Horn OH/UG — 22 kA
RC816F100SH [21]
[22] [23] [24]
1
QOM2100VH
[25]
100 A 8 16 8 100 A
A
6–350
8–2/0
43, 21
100 A Horn OH/UG — 22 kA
RC816F100CH[21]
[22] [23]
1
QOM2100VH
[25]
100 A 8 16 8 100 A 12-2/0
40, 21
125 A Horn OH/UG — 22 kA
RC816F125SH [21]
[23] [24]
1
QOM2125VH
[25]
125 A 8 16 8 100 A 8–2/0
43, 21
125 A Horn OH/UG — 22 kA
RC816F125CH [21]
[22]
1
QOM2125VH
[25]
125 A 8 16 8 100 A 12-2/0
40, 21
150 A
None OH/UG — 22 kA
RC816F150S [21] [22]
[24]
1
QOM2150VH
[25]
150 A 8 16 8
150 A
[29]
8–2/0
43, 21
None OH/UG — 22 kA
RC816F150C [21] [22]
1
QOM2150VH
[25]
150 A 8 16 8
150 A
[29]
12-2/0
40, 21
Horn OH/UG — 22 kA
RC816F150SH [21]
[22] [23] [24]
1
QOM2150VH
[25]
150 A 8 16 8
150 A
[29]
8–2/0
43, 21
Horn OH/UG — 22 kA
RC816F150CH [21]
[22] [23]
1
QOM2150VH
[25]
150 A 8 16 8
150 A
[29]
12-2/0
40, 21
Lever OH/UG — 22 kA
RC816F150SL [22]
[23] [30]
1
QOM2150VH
[25]
200 A 8 16 8 150 A 8-2/0 72 / 12
200 A
None OH/UG — 22 kA
RC816F200S [21] [22]
[23] [24]
1
QOM2200VH
[25]
200 A 8 16 8
200 A
[26]
8–2/0
43, 21
None OH/UG — 22 kA
RC816F200C [21] [22]
1
QOM2200VH
[25]
200 A 8 16 8
200 A
[26]
12-2/0
40, 21
Horn OH/UG — 22 kA
RC816F200SH [21]
[22] [23] [24]
1
QOM2200VH
[25]
200 A 8 16 8
200 A
[26]
8–2/0
43, 21
Horn OH/UG — 22 kA
RC816F200CH [21]
[22] [23]
1
QOM2200VH
[25]
200 A 8 16 8
200 A
[26]
12-2/0
40, 21
Lever OH/UG — 22 kA
RC816F200SL [21]
[22] [23] [30]
1
QOM2200VH
[25]
200 A 8 16 8 200 A 8-2/0 72 / 12
200 A Horn OH/UG — 10 kA
RC816D200CH [31]
[21] [23] [27]
1
HOM2200 [25]
200 A
8 16 8
100 A
[32]
6–300 6–1/0
48, 18
1 HOM 50 A
[18] To order branch circuit breakers, see QO Plug-On Circuit Breakers, page 1-3
[19] To order hubs, see Accessories and Hubs for CSEDs, page 1-38
[20] To order service disconnects, see Circuit Breakers for CSEDs, page 1-37 except as noted)
[21] Supplied with load side feed-thru lugs, for 4 AWG–250 kcmil (Al/Cu) conductors.
[22] Device supplied with barrel lock provisions factory-installed.
[23] 5th jaw factory-installed.
[24] Suitable for load wires to exit top endwall with addition of Tunnel Kit OHBS, see Table 1.82 Accessories, page 1-38, check with local utility for approval.
[25] Service disconnect supplied factory-installed.
[26] Use only 15–100 A and 150–200 A circuit breakers.
[27] Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories).
[28] 125 A Homeline™ 2P circuit breaker can be installed in top position only. All other positions are limited to 100 A max.
[29] Use only 15–100 A and 150 A circuit breakers.
[30] Suitable for load wires to exit top endwall with addition of Tunnel Kit OHBL, see Table 1.82 Accessories, page 1-38, check with local utility for approval.
[31] Convertible to semiflush with SC200F flange kit (order separately).
[32] A 100 A circuit breaker can be installed in bottom position only, all other positions are limited to 70 A max.