Technical Data Bulletin

1-26
© 2020 Schneider Electric
All Rights Reserved
10/30/2020
QO/Homeline Load Center Value Packs and
Accessories
QO Load Center Accessories
www.se.com/us
Class 1130 / Refer to Catalog 1100CT0501
1
LOAD CENTERS
QO Load Center Accessories
Table 1.65: QO Load Center Accessories
Description
Cat. No. Schedule
Retaining Kit for Breakers
Used as Back-fed Mains
Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB,
QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers
PK2MB DE3A
Secures 3P circuit breaker without accessories to left side of interior when used as a back-fed main. For load centers PK3MB DE3A
Secures circuit breaker to interior when used as a back-fed main for 2P QO 150–200 A circuit breakers
PK5RK DE3A
Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main
For 100–125 ampere convertible main load centers. Series S01 and S02
PK4MB2LA DE3A
Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main
For 150–225 ampere convertible main load centers. Series S01 and S02
PK4MB2HA DE3A
Cover Sealing Strap Provides means of sealing trim mounting screws on QO load center covers
QO1SE
DE3A
Replacement Cover
Directory Label
1 through 42 numbered universal replacement directory label for load center covers
LSDL DE5
Circuit Identification
Stickers
Circuit identification stickers for use on cover directory labels to identify branch circuits
PSDS DE5
Filler Plates
Fills opening in covers if twistout is removed in error
QOFP
DE3A
Fills main circuit breaker opening in convertible load center covers 100–125 A
QOM1FP
DE3A
Fills main circuit breaker opening in convertible load center covers 150–225 A
QOM2FP
DE3A
Fills main circuit breaker opening in load center covers (S01 and S02 Series)
KFP DE3A
Fills main circuit breaker opening in “Q” style load center covers (S03 Series)
Q2FP
DE3A
Door Lock Kits
Use with QO612L100DF/S, QO612L100DFCU/SCU, QO612L100DTF/S, QO816L100DF/S, QO816L100DFCU/SCU,
QO816L100DTF/S, QO48M30DSGP, or QO48M60DSGP
PK8FL [4]
DE3A
Use with convertible mains, and 100–225 A, and fixed mains,
125–225 A indoor load centers
PK6FL DE3A
Use with 300 and 400 ampere indoor load centers
PK4FL PE1A
Neutral / Ground Lugs
Field-installed for 12– 2 Al or 14–4 Cu AWG wire LK70AN DE3A
Field-installed for 6–2/0 Al/Cu AWG wire LK100AN DE3A
Field-installed for 14–2/0 Al/Cu AWG wire LK125AN DE3A
Field-installed for 2–3/0 Al/Cu AWG wire LK150AN DE3A
Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S,
150-225A QO load center or S03 and below, 150-225A HOM load center
LK225AN
LK225ANHOM
DE3A
Ground Bar Kits
Standard PK15GTA with a 1–4/0 Al/Cu Lug
PK15GTAL DE3A
Standard PK18GTA with a 1–4/0 Al/Cu Lug
PK18GTAL DE3A
Standard PK23GTA with a 1–4/0 Al/Cu Lug
PK23GTAL DE3A
Insulator Kit for PK7GTA through PK27GTA
PKGTAB DE3A
Neutral Bonding Screws
For use on all Homeline and QO 125A convertible main load center
4028344850K DES
For use on QO 150A–225A convertible main load centers
4028345850K DEW
Handle Padlock
Attachments
For padlocking main circuit breakers in convertible load centers OFF: 50A–125A
QOM1PA
DE2E
For padlocking main circuit breakers in convertible load centers OFF: 100A–225A
QOM2PA
DE2E
Service Entrance Barriers
QO / Homeline 100–125 A QOM1 convertible main load centers
PKSB1LA DE3A
QO / Homeline 150–225 A QOM2 convertible main load centers
PKSB1HA DE3A
QO convertible main load centers
PKSB3 DE3A
QO back-fed main breaker applications
PKSB1QOBF
DE3A
QO back-fed main breaker applications
PKSB3BF DE3A
QO Load Center Manual Power Transfer Accessories
Manual Transfer
Equipment Kit
For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that only one
circuit breaker can be “ON’’ at a time.
QO2DTI
DE2E
QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power
supply applications. Can be used with (2) 2P or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers.
QO2DTIM
DE2E
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power
supply applications. For 100–125 ampere convertible main load centers. Series S01 and S02.
PK4DTIM4LA DE3A
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power
supply applications. For 150–225 ampere convertible main load centers. Series S01 and S02.
PK4DTIM4HA DE3A
Secures two 2P circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power
supply applications. For 100–125 ampere convertible main load centers. Series S01 and S02.
PK4DTIM4LAL DE3A
Generator Circuit Breaker
Interlock Kit
For use on “G” and “S” Series NEMA 1 and “G”, “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P main circuit
breaker of a load center (100–125 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit.
QOCRBGK1C
DE3A
For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit
breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit.
QOCGK2C
DE3A
For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a
QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit.
QORBGK2C
DE3A
PK3MB
PK2MB
PK6FL and PK8FL
PK4FL
PKGTAB
QOFP
[4] QO403L60NF/S does not have provisions for a field-installed lock.