Technical Data Bulletin
Table Of Contents
- Section 1 Load Centers
- EZ Selector - Selection Assistance
- QO™ Miniature Circuit Breakers
- QO™ Load Centers
- Homeline™ Miniature Circuit Breakers
- Homeline™ Load Centers
- QO/Homeline Load Center Value Packs and Accessories
- QO/Homeline Load Center Dimensions
- Combination Service Entrance Devices
- RC/QC Solar Ready CSEDs
- Homeline Solar Ready PoN CSEDs
- Wiser Energy™
- Enclosed Devices
- Servicepak™ Power Outlet Panels
© 2020 Schneider Electric
All Rights Reserved
10/30/2020
1-25
www.se.com/us
Value Packs
QO/Homeline Load Center Value Packs and
Accessories
Class 1130, 1170 / Refer to Catalog 1100CT0501
Plug-on Neutral Indoor Load Center Value Packs
Table 1.61: Plug-on Neutral Indoor Load Center Value Packs (Compatible with Plug-on and Plug-on Neutral Circuit Breakers)
Mains
Rating
Spac-
es
Max. 1P
Circuits
[1]
Max.
Tandem
Circuit
Breakers
Load Center
Box, Interior, Cover and Branch Circuit Breakers
Equipment
Ground Bar Kit
(Order
Separately)
Main
Wire Size|
AWG/kcmil|
Al/Cu
Box
No.
[2]
Cat. No. Included Load Center/Circuit Breakers Cat. No.
I
N
D
O
O
R
QO (Accepts Only QO Plug-On Circuit Breakers) QO—Copper Bus; Convertible Mains—Factory-Installed Main Circuit Breaker,
22 kA Short Circuit Current Rating Convertible appropriate to Main Lugs (See page 1-10) or QOM Main Circuit Breaker (See page 1-21)
125 A 24 34 10
QO124L125PGCVP
(1) QO124L125PGC, (3) QO120, (2) QO230
PK15GTA Included 6–2/0 7
225 A 42 52 10
QO142L225PGCVP
(1) QO142L225PGC, (3) QO120, (2) QO230
PK23GTA Included 4–300 11
Convertible Mains—Factory-Installed Main Circuit Breaker,
22 kA Short Circuit Current Rating Convertible appropriate to Main Lugs or Main Circuit Breaker (See page 1-24)
100 A
24 34 10
QO124M100PCVP
(1) QO124M100PC, (3) QO120, (2) QO230
PK15GTA 6–2/0 7
32 38 6
QO132M100PCVP
(1) QO132M100PC, (3) QO120, (2) QO230
PK18GTA 6–2/0 8
200 A
42 52 10
QO142M200PCVP
(1) QO142M200PC, (3) QO120, (2) QO230
PK23GTA
4–300
11
42 52 10
QO142M200PCAFVP
(1) QO142M200PC, (3) QO120, (2) QO230, (3) QO115PCAFI
PK23GTA 11
Homeline (Accepts Only HOM Plug-On Circuit Breakers); Convertible Mains—Factory-Installed Main Lugs,
10 kA Short Circuit Current Rating Convertible to appropriate QOM 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-24)
125 A 12 24 12 HOM1224L125PGCVP
(1) HOM1224L125PGC, (2) HOM120
PK9GTA, PK9GTA
W/LK100AN
Included
6–2/0 6–1 6
225 A 30 60 30 HOM3060L225PGCVP
(1) HOM3060L225PGC, (3) HOM120, (2) HOM230
PK18GTAL
Included
PK9GTA Included
4–
300
4–
250
10
Convertible Mains—Factory-Installed Main Circuit Breaker,
22 kA Short Circuit Current Rating Convertible appropriate to Main Lugs or Main Circuit Breaker (See page 1-24)
100 A
20 40 20 HOM2040M100PCVP
(1) HOM2040M100PC, (2) HOM120, (1) HOM230
PK18GTA 6–1 6–3 7
20 40 20 HOM2040M100PC1AVP
(1) HOM2040M100PC, (2) HOM120, (1) HOM230, (1) HOM115PCAFI
PK18GTA 6–1 6–3 7
24 48 24 HOM2448M100PCVP
(1) HOM2448M100PC, (3) HOM120, (2) HOM230
PK23GTA 6–2/0
6–1/
0
8
150 A 30 30 30 HOM3060M150PCVP
(1) HOM3060M150PC, (3) HOM120, (2) HOM230
PK23GTA 4–250
200 A
20 40 20 HOM2040M200PCVP
(1) HOM2040M200PC, (3) HOM120, (2) HOM230
PK18GTA
4–250
9
30 60 30 HOM3060M200PCVP
(1) HOM3060M200PC, (3) HOM120, (2) HOM230
PK23GTA 10
30 60 30 HOM3060M200PC1AVP
(1) HOM3060M200PC, (3) HOM120, (2) HOM230, (1) HOM115PCAFI
PK23GTA 10
30 60 30
HOM3060M200P-
CAFVP
(1) HOM3060M200PC, (3) HOM120, (2) HOM230, (3) HOM115PCAFI
PK23GTA 10
40 80 40 HOM4080M200PCVP
(1) HOM4080M200PC, (3) HOM120, (2) HOM230
PK27GTA 12
40 80 40 HOM4080M200PC1AVP
(1) HOM4080M200PC, (3) HOM120, (2) HOM230, (1) HOM115PCAFI
PK27GTA 12
40 80 40
HOM4080M200P-
CAFVP
(1) HOM4080M200PC, (3) HOM120, (2) HOM230, (3) HOM115PCAFI
PK27GTA 12
Table 1.62: Plug-on Neutral with Qwik-Grip Indoor Load Center Value Packs (Compatible with Plug-on and Plug-on Neutral Breakers)
Main
Rat-
ings
Spaces
Max. 1P
Circuits
Max.
Tandem|
Circuit
Breakers
Load Center
Box, Interior, Cover and Branch Circuit Breakers
Equipment
Ground Bar Kit
(Order Separately)
Main
Wire Size|
AWG/kcmil|
Al/Cu
Box
No.
[3]
Cat. No. Included Load Center/Circuit Breakers Cat. No.
I
N
D
O
O
R
QO Convertible Mains—Factory-Installed Main Lugs, up to 65 kA Short Circuit Current Rating—Copper Bus, QOM1 Main Frame Size, Convertible to Main Circuit breaker
125 A 24 34 10
QO124L125PQGCVP
(1) QO124L125PQGC, (3) QO120, (2) QO230 and (1) PKQGA
Qwik-Grip assembly kit
PK15GTAL
Included
6–2/0
7Q
QO Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating—Copper Bus, QOM2 Main Frame Size, Convertible to Main Lugs or Main Circuit breaker
200 A 42 52 10
QO142M200PQCVP
(1) QO142M200PQC, (3) QO120, (2) QO230 and (1) PKQGA
Qwik-Grip assembly kit
PK23GTA
(Order separately)
4–250
11Q
Homeline Convertible Mains—Factory-Installed Main Circuit breaker, 22kA Short Circuit Current Rating—Copper Bus, QOM1 Main Frame Size, Convertible to Main Lugs or Main Breaker
100 A 20 40 20
HOM2040M100PQCVP
(1) HOM2040M100PQC, (2) HOM120, (1) HOM230 and (1)
PKQGA Qwik-Grip assembly kit
PK18GTA
(Order separately)
6–2/0 6–1 6
200 A
30 60 30
HOM3060M200PQCVP
(1) HOM3060M200PQC, (3) HOM120, (2) HOM230 and (1)
PKQGA Qwik-Grip assembly kit
PK23GTA
(Order separately)
4–250
10Q
40 80 40
HOM4080M200PQCVP
(1) HOM4080M200PQC, (2) HOM120, (1) HOM230 and (1)
PKQGA Qwik-Grip assembly kit
PK27GTA
(Order separately)
4–250
12Q
Table 1.63: Plug-on Neutral Rainproof Load Center Value Packs (Compatible with Plug-on and Plug-on Neutral Circuit Breakers)
Main
Rat-
ings
Spaces
Max. 1P
Circuits
Max.
Tandem
Circuit
Breakers
Load Center
Box, Interior, Cover and Branch Circuit Breakers
Equipment
Ground Bar Kit
(Order Separately)
Main
Wire Size
AWG/kcmil
Al/Cu
Box
No.
[3]
Cat. No. Included Load Center/Circuit Breakers Cat. No.
R
A
I
N
P
R
O
O
F
Homeline (Accepts Only HOM Plug-On Circuit Breakers)
Convertible Mains—Factory-Installed Main Circuit Breaker,
22 kA Short Circuit Current Rating Convertible to Main Lugs or Lower Amperage QOM2 Main Circuit Breaker (See page 1-24)
125 A 12 24 12 HOM1224M125PRBVP
(1) HOM1224M125PRB, (3) HOM120, (2) HOM230
PK23GTA 6–2/0 6–1 3R
200 A 30 60 30 HOM3060M200PRBVP
(1) HOM3060M200PRB, (3) HOM120, (2) HOM230
PK23GTA 4–250 7R
Table 1.64: Plug-on Neutral Load Center Surge Packs (Compatible with Plug-On and Plug-On Neutral Circuit Breakers)
Mains
Rating
Max. 1P
Circuits
Max.
Tandem
Circuit
Break-
ers
Load Center Box, Interior, Cover and Branch Circuit Breakers
Equipment Ground
Bars
Main Wire Size
AWG/kcmil
Box
No.
Catalog Number
Included Load Center / Circuit Breakers / SPD
Catalog Number
Al Cu
Indoor 225 60 30 HOM3060L225PGCSVP2
(1) HOM3060l225PGC, (1) HOM230, (2) HOM120,
(1) Plug-on Neutral HOM250PSPD, Cover & Ground Bar
PK9GTA,
PK18GTAL (included)
4-300 4-250 10
Rainproof
200 16 8 HOM816M200PFTRBSP2
(1) HOM816M200PFTRB & (1) Plug-on Neutral
HOM250PSPD
PK15GTA
(order separately)
4-250 6R
1
LOAD CENTERS
[1] Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
[2] See page 1-29 or page 1-31
[3] See page 1-29