QO Indoor, Rainproof Load Centers, 3Ø
QO™ Load Centers
Class 1130 / Refer to Catalog 1100CT0501
QO Standard Load Center Main Lugs and Main Breaker
(3Ø4W—208Y/120 Vac, 3Ø4W—240/120 Vac Delta
and 3Ø3W—240 Vac Delta—Indoor and Rainproof—UL Listed)
Table 1.36: Main Lugs and Main Breaker Load Centers (Accepts Only QO Plug-on Circuit Breakers - Not compatible with QO Plug-on
Neutral Circuit Breakers)
Mains
Rating
Max. Number
of 1P QO
circuit
breakers
Load Center
Box and Interior
Indoor Cover with Door
(Order Separately)
Main
Wire Size
AWG/kcmil
Equipment
Ground Bar Kit
(Order Separately)
Box No.
[63]
Cat. No. Flush Surface Al Cu
I
N
D
O
O
R
Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Rating [64]
60 A 3
QO403L60NF/S
Cover Included With Load Center (No
Door)
— 10–6 PK4GTA 13
125 A
12
QO312L125G [65]
QOC16UF QOC16US
6–2/0 6–2/0
Factory-incl. [66]
6
20
QO320L125G [65]
QOC24UF QOC24US
Factory-incl. [66]
7
24
QO324L125G [65]
QOC24UF QOC24US
Factory-incl. [66]
7
200 A
18
QO318L200G [65]
QOC30UF QOC30US
6–250 6–250
Factory-incl. [67]
9
30
QO330L200G [65]
QOC30UF QOC30US
Factory-incl. [67]
9
225 A 42
QO342L225G [65]
QOC42UF QOC42US
6–300 6–300
Factory-incl. [67]
11
Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Rating [68]
100 A 27
QO327M100 [69]
QOC30UF QOC30US
4–2/0 4–2/0 PK15GTA 9
125 A 30
QO330MQ125[70] [65]
QOC342MQF QOC342MQS
4–300 4–300 PK18GTA 12
150 A
30
QO330MQ150[70] [65]
QOC342MQF QOC342MQS
4–300 4–300
PK18GTA 12
42
QO342MQ150[70] [65]
QOC342MQF QOC342MQS
PK23GTA 12
200 A
30
QO330MQ200[70] [65]
QOC342MQF QOC342MQS
4–300 4–300
PK18GTA 12
42
QO342MQ200[70] [65]
QOC342MQF QOC342MQS
PK23GTA 12
225 A 42
QO342MQ225[70] [65]
QOC342MQF QOC342MQS
4–300 4–300 PK23GTA 12
R
A
I
N
P
R
O
O
F
Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Rating [64] [71]
60 A 3
QO403L60NRB
Cover Included
— 10–6 PK4GTA 10R
125 A
12
QO312L125GRB
6–2/0 6–2/0
Factory Incl. [66]
3R
20
QO320L125GRB
Factory Incl. [66]
4R
200 A
18
QO318L200GRB
6–250 6–250
Factory Incl. [67]
6R
30
QO330L200GRB
Factory Incl. [67]
6R
225 A 42
QO342L225GRB
6–300 6–300
Factory Incl. [67]
8R
Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Rating [68] [71]
100 A 27
QO327M100RB [69]
Cover Included
4–2/0 4–2/0 PK15GTA 6R
125 A 30
QO330MQ125RB [70]
4–300 4–300 PK18GTA 14R
150 A 30
QO330MQ150RB [70]
4–300 4–300 PK18GTA 14R
200 A
30
QO330MQ200RB[70]
4–300 4–300
PK18GTA 14R
42
QO342MQ200RB [70]
PK23GTA 14R
225 A 42
QO342MQ225RB [70]
4–300 4–300 PK23GTA 14R
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
QO342MQ200 QO312L125G
Table 1.37: 3Ø, Main Circuit Breakers
Amperage
25 k AIR 65 k AIR
100 k AIR [72]
Field-installed alternate main circuit breakers for QO 3Ø main circuit breaker load centers rated 70–225 A.
Do not exceed the load center main rating.
70 A
QDL32070 QGL32070 QJL32070
80 A
QDL32080 QGL32080 QJL32080
90 A
QDL32090 QGL32090 QJL32090
100 A
QDL32100 QGL32100 QJL32100
110 A
QDL32110 QGL32110 QJL32110
125 A
QDL32125 QGL32125 QJL32125
150 A
QDL32150 QGL32150 QJL32150
175 A
QDL32175 QGL32175 QJL32175
200 A
QDL32200 QGL32200 QJL32200
225 A
QDL32225 QGL32225 QJL32225
Table 1.38: 3Ø, Main Lugs Kits
Main Lugs
Amperage Rating
Cat. No.
Lug Wire Size
AWG/kcmil
Field-installed main lugs for convertible 3Ø main circuit breaker load centers
125 A
QOL3125
6–2/0 Cu/Al
225 A
QOL3225
6–300 Cu/Al
1
LOAD CENTERS
[63] See page 1-29
[64] UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
[65] For Certification to IEC 60439-1 contact the local Square D sales office; otherwise panels are NOT CE marked. (For use on 415Y/240 Vac 3-phase 4-wire, 3,000 Short Circuit Current Rating
when QOXD...branch circuit breakers are used and 10,000 Short Circuit Current Rating when QO...VS branch circuit breakers are used).
[66] PK15GTA.
[67] PK23GTA and LK100AN.
[68] 25 kA short circuit current rating SSCR maximum with Square D Type QDL main circuit breaker, or 22 kA SCCR maximum with back-fed Type QO-VH main circuit breaker, feeding QO 10 k
AIR branch circuit breakers.
[69] Includes factory-installed back fed QO3100VH main circuit breaker.
[70] 65 kA Short Circuit Current Rating maximum with field-installed Square D type QGL 65 k AIR minimum main circuit breaker feeding QO and Q1 10 k AIR minimum branch circuit breakers.
[71] Side hinge door device allow 1-1/4 in. on left side for door to open.
[72] When these 3P circuit breakers are used as the main circuit breaker of a 3Ø load center, the maximum AIR rating is 65 kA at 240 Vac and 100 kA at 208 Vac.