QO™ Load Centers
QO Special Constructions, 1Ø
www.se.com/us
Class 1130 / Refer to Catalog 1100CT0501
1
LOAD CENTERS
QO Riser Panels
(1Ø3W—120/240 Vac Special Applications—UL Listed)
Table 1.33: Riser Panels for Offset Interior for Wide Gutter—30 A Maximum Branch Circuit Breaker on Left Side of Interior [55] , [56]
(Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers)
Mains
Rating
Spaces
Max.
Single Pole
Circuits [57]
Max. Tandem Circuit
Breakers
Load Center Box and
Interior
Load Center Cover
Equipment
Ground Bar Kit
(Order
Separately)
Main Wire Size
AWG/kcmil Box No.
[58]
Flush (Gray) Flush (White)
Al Cu
I
N
D
O
O
R
Convertible Mains—Factory-Installed Main Lugs, 65 kA Short Circuit Current Rating Convertible to QOM1 22 kA Short Circuit Current Rating Main Circuit Breaker (See page ) when used
with QOC cover below—Copper Bus
125 A
12 24 12
QO112L125PWG QOC20UFWG QOC20UFWGW
PK15GTA
6–2/0
14
20 24 4
QO120L125PWG QOC20UFWG QOC20UFWGW
PK15GTA 14
Convertible Mains-Factory—Installed Main Lugs, 65 kA Short Circuit Current Rating Convertible to QOM2 22 kA Short Circuit Current Rating Main Circuit Breaker (See page ) when used
with QOC cover below—Copper Bus
200 A 30 40 10
QO130L200PWG QOC30UFWG QOC30UFWGW
PK23GTA 4–250 23
Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible to Main Lugs (See page )
or Lower Amperage QOM2 Main Circuit Breaker (See page )when used with QOC cover below—Copper Bus
200 A 24 36 12
QO124M200PWG125
[59]
QOC30UFWG QOC30UFWGW
PK23GTA 4–250 23
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
Panelboard-style Covers for Riser Panels
Mains Rating of Load Center
Cat. No.
125 A
NQC20FWG
200 A
NQC30FWG
Mono-Flat
™
Front available for riser panels as an alternative to standard load center
cover listed above. Provides a low-profile, aesthetically pleasing solution for high-traffic
areas in upscale multi-family applications. Deadfront included. Lock kit not provided.
Cover NQC30FWG CANNOT be used when panel has been converted to a main circuit
breaker panel.
[60]
Table 1.34: Auxiliary Gutter
Cat. No. Cover Conduit Riser Size Width
Height Depth
UL Listed for use with standard 1Ø and 3Ø load centers for riser applications [61]. For auxiliary gutter-load center compatibility, see catalog number 1100CT0501
SDAG26 Flush
1-3/4, 2, 2-1/2 or [62] 3
13.50 26.12 3.75
Table 1.35: Tap Kits for Use with Auxiliary Gutter
Cat. N0.
Use with Auxiliary
Gutter Cat. No.
Riser Wire
Tap Off Wire
Lug Type
Al/Cu Wire Size
Lug Type
Al/Cu Wire Size
SDGT30020 SDAG26
Mechanical (Included) (2) 6 AWG–300 kcmil Mechanical (Included) (1) 6–2/0 AWG
SDGT300300 SDAG26
Mechanical (Included) (2) 6 AWG–300 kcmil Mechanical (Included) (1) 6 AWG–300 kcmil
SDGT300C10C SDAG26
Anderson VCEL030516H1 (Not included) (2) 4 AWG–300 kcmil Anderson VCEL02114S1 (Not Included) (1) 8–1/0 AWG
SDGT300C300C SDAG26
Anderson VCEL030516H1 (Not included) (2) 4 AWG–300 kcmil
Anderson VCEL030516H1 (Not
included)
(1) 4 AWG–300 kcmil
QOGL20
Grounding Terminals
SDAG26
Mechanical (Included) (2) 6–2/0 AWG
— —
[55] UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
[56] UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
[57] Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
[58] See page 1-29
[59] Comes with 125 A main circuit breaker factory installed.
[60] Order catalog number PK4FL for field-installed lock kit.
[61] One tap kit required for each riser wire.
[62] When used with B300 bolt-on hubs.