Technical Data Bulletin

1-12
© 2020 Schneider Electric
All Rights Reserved
11/5/2020
QO™ Load Centers
QO Load Centers, Rainproof,
www.se.com/us
Class 1130 / Refer to Catalog 1100CT0501
1
LOAD CENTERS
Plug–on Neutral Load Center Main Lugs, Convertible Mains
(1Ø3W—120/240 Vac Rainproof—UL Listed)
QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plug-
on Neutral connection on every unit.
Table 1.24: Convertible Main Lugs Plug-on Neutral Load Center (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral
Circuit Breakers)
Mains
Rating
Spaces
Max.
Single Pole
Circuits [18]
Max.
Tandem
Circuit
Breakers
Load Center
Box and Interior
Al Cu
Equipment
Ground Bar Kit
(Order Separately)
Box No.
[19]
R
A
I
N
P
R
O
O
F
Convertible Mains Factory-Installed Main Lugs 65 kA Short Circuit Current Rating [20][21][22]
QOM1 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker Equipment Ground Bar Included
 125 A
12  24 12
QO112L125PGRB
6–2/0
PK9GTA, PK9GTA W/LK100AN Factory-included
3R
16  24 8
QO116L125PGRB
6–2/0
PK9GTA, PK9GTA W/LK100AN Factory-included
4R
24  34 10
QO124L125PGRB
6–2/0
PK15GTA Factory-included
4R
Convertible Mains Factory-Installed Main Lugs 65 kA Short Circuit Current Rating [20][21][22]
QOM2 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker Equipment Ground Bar Included
200 A
12 24 12
QO112L200PGRB
4–300 4–250
PK9GTA, PK9GTA W/LK100AN Factory-included
5R
30 40 10
QO130L200PGRB
4–250
PK23GTAL Factory-included
6R
40 60 20
QO140L200PGRB
4–300 4–250
PK9GTA,
PK18GTAL Factory-included
7R
225 A 42 52 10
QO142L225PGRB
4–300
PK23GTA, LK100AN Factory-included
8R
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
Plug–on Neutral Load Center Main Breaker, Convertible Mains
(1Ø3W—120/240 Vac Rainproof—UL Listed)
QO Plug-on Neutral Load Centers and CAFI circuit breakers are engineered for a quick
Plug-on Neutral connection on every unit.
Table 1.25: Convertible Main Breaker Plug-on Neutral Load Center (Compatible with QO Plug-on Circuit Breakers and QO Plug-on
Neutral Circuit Breakers)
Mains
Rating
Spaces
Max.
Single Pole
Circuits [18]
Max.
Tandem
Circuit
Breakers
Load Center
Box and Interior
Al Cu
Equipment
Ground Bar Kit
(Order Separately)
Box No.
[19]
R
A
I
N
P
R
O
O
F
Convertible Mains
Factory-Installed Main Breaker 22 kA Short Circuit Current Rating
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-3)[23]
QOM1 Main Circuit Breaker Frame Size—Copper Bus
 100 A
12 24 12
QO112M100PRB
6–2/0 PK9GTA 3R
16 24 8
QO116M100PRB
6–2/0 PK9GTA 4R
20 24 4
QO120M100PRB
6–2/0 PK9GTA 4R
24 34 10
QO124M100PRB
6–2/0 PK15GTA 4R
 125 A 24 34 10
QO124M125PRB
6–2/0 PK15GTA 4R
Convertible Mains
Factory-Installed Main Breaker 22 kA Short Circuit Current Rating
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-3) [23]
QOM2 Main Circuit Breaker Frame Size—Copper Bus
150 A
20 30 10
QO120M150PRB
4–300 4–250 PK15GTA 5R
30 40 10
QO130M150PRB
4–250 PK15GTA 6R
200 A
20 30 10
QO120M200PRB
4–300 4–250 PK15GTA 5R
30 40 10
QO130M200PRB
4–250 PK15GTA 6R
40 60 20
QO140M200PRB
4–300 4–250 PK23GTA 7R
42 52 10
QO142M200PRB
4–300 PK18GTA 8R
225 A 42 52 10
QO142M225PRB
4–300 PK18GTA 8R
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
[18] Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
[19] See Table 1.72 Enclosure Dimensions, page 1-31 or Indoor Enclosure Dimensions and Knockout Information, page 1-29
[20] UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
[21] UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
[22] Side hinge door device; allow 1-1/4 in. on left side for door to open.
[23] 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, QO-AFI, QO-EPD and QOPL 10 k AIR branch circuit breakers to permit their application on systems up to 22
kA