Table of Contents Load Centers Load Center EZ Selector - Selection Assistance QO™ Miniature Circuit Breakers QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers QO Accessories QO™ Load Centers Value Packs QO Load Center Accessories Homeline Load Center Accessories Qwik-Grip Load Center Accessories Surge Protective Devices QO/Homeline Load Center Dimensions Indoor Enclosure Dimensions and Knockout Information Rainproof, Dimensions, Knockouts and Bolt-on Hubs Combination Service Entrance Devices
EZ Selector - Selection Assistance 1 Load Center EZ Selector - Selection Assistance www.se.com/us Class 1140 QO™ and Homeline™ Load Center EZ Selector - Selection Assistance LOAD CENTERS EZ Selector Steps to select a load center. 1. Select product type: • Homeline™ 1 inch format (HOM) • QO™ 3/4 inch format with plug-on neutral (QO) (P) • QO™ 3/4 inch format (QO) 2. Select enclosure type: indoor or outdoor (RB = rainproof) 3. Select single phase (1) or three phase (3) 4.
QO Plug-On Circuit Breakers QO™ Miniature Circuit Breakers Class 730, 731, 733 / Refer to Catalog: 0730CT9801 www.se.com/us Square D brand QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD and NQ panelboards, NQOD and NQ OEM interiors or Speed-D™ switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD and NQ panelboards or interiors.
QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers 1 Class 730, 731, 733 / Refer to Catalog: 0730CT9801 www.se.com/us QO/QOB Ring Terminal Table 1.2: QO/QOB Ring Terminal—Factory-Installed Only LOAD CENTERS Ampere Rating 10–30 A 35–60 A 35–50 A 70–110 A 60–100 A Poles 1, 2, 3 1,2 3 2 3 Suffix 5237 5238 5273 Wire Sizes for QO/QOB Circuit Breakers Table 1.
QO Plug-On Circuit Breakers www.se.com/us QO™ Miniature Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 Qwik-Gard™ circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping.
QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers 1 Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 www.se.com/us QO-EPD/EPE Circuit Breakers QO-EPD/EPE circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 mA level (EPD) or 100 mA level (EPE). They are not designed to protect people from electrical shock. LOAD CENTERS Table 1.
QO Plug-On Circuit Breakers www.se.com/us QO™ Miniature Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Table 1.
QO™ Miniature Circuit Breakers QO Accessories 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Accessories for QO/QOB Circuit Breakers Table 1.15: Accessories for use with QO and QOB Miniature Circuit Breakers Description Cat. No.
QO™ Load Centers QO Indoor Load Centers, 1Ø www.se.com/us Plug-on Neutral Load Center Main Lugs, Convertible Mains (1Ø3W—120/240 Vac Indoor—UL Listed) QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plugon Neutral connection on every unit. Table 1.
QO™ Load Centers QO Indoor Load Centers, 1Ø 1 Class 736, 1130 / Refer to Catalog 1100CT0501 www.se.com/us Field-Installed Main Circuit Breaker Kits, 1Ø Table 1.
QO™ Load Centers QO Indoor Load Centers, 1Ø Class 736, 1130 / Refer to Catalog 1100CT0501 www.se.com/us The Square D QO plug-on neutral load centers with Qwik-Grip simplify rough-in by eliminating the need to remove knockouts, install wire connectors, and blindly pull wire into the load center. A quick bend of the wire using the wire bend guide on the Qwik-Grip insert and the wire slides into the slot.
QO™ Load Centers QO Load Centers, Rainproof, 1Ø 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Plug–on Neutral Load Center Main Lugs, Convertible Mains (1Ø3W—120/240 Vac Rainproof—UL Listed) LOAD CENTERS QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plugon Neutral connection on every unit. Table 1.24: Convertible Main Lugs Plug-on Neutral Load Center (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) Max.
QO™ Load Centers Backup Power Solutions, 1Ø Backup Power Solutions (1Ø3W—120/240 Vac Backup Power—UL Listed) Table 1.26: Backup Power Solutions Mains Rating (A) I N D O O R R A I N P R O O F Spaces Max. Single Pole Circuits [24] Max.
QO™ Load Centers QO Special Constructions, 1Ø 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us QO Standard Load Center Main Lugs and Main Breaker, Fixed Mains (1Ø3W—120/240 Vac Special Applications—UL Listed) LOAD CENTERS Table 1.28: Low Amperage Fixed Main Lugs Indoor Load Centers (Accepts Only QO Plug-on Circuit Breakers - Not compatible with QO Plug-on Neutral Circuit Breakers) Max. Max.
QO™ Load Centers QO Special Constructions, 1Ø Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Mains Rating R A I N P R O O F Spaces Max. Single Pole Circuits [47] Max.
QO™ Load Centers QO Special Constructions, 1Ø 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us QO Riser Panels (1Ø3W—120/240 Vac Special Applications—UL Listed) Table 1.
QO™ Load Centers QO Indoor, Rainproof Load Centers, 3Ø QO Standard Load Center Main Lugs and Main Breaker (3Ø4W—208Y/120 Vac, 3Ø4W—240/120 Vac Delta and 3Ø3W—240 Vac Delta—Indoor and Rainproof—UL Listed) Table 1.36: Main Lugs and Main Breaker Load Centers (Accepts Only QO Plug-on Circuit Breakers - Not compatible with QO Plug-on Neutral Circuit Breakers) Cu Equipment Ground Bar Kit (Order Separately) Box No. [63] 10–6 6–2/0 6–250 6–300 PK4GTA 13 Factory-incl. [66] Factory-incl. [66] Factory-incl.
Homeline™ Miniature Circuit Breakers Homeline Plug-On Circuit Breakers 1 Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Homeline Standard Plug-On Circuit Breakers LOAD CENTERS The Square D Homeline circuit breakers are in a 1 in. wide format for 1-pole circuit breakers. They are designed to plug into Homeline load centers. Table 1.
Homeline Plug-On Circuit Breakers Homeline™ Miniature Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Homeline Combination Arc Fault and Ground Fault Circuit Interrupters (Dual Function)— Provide overload and short circuit protection, plus arc fault and ground fault protection in a single device in accordance with the NEC, UL1699 and UL943. Table 1.
Homeline Accessories Homeline™ Miniature Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 1 www.se.com/us Homeline Circuit Breaker Wire Sizes Table 1.
Homeline™ Load Centers Homeline Load Centers, Indoor, 1Ø Class 1170 / Refer to Catalog 1100CT0501 Table 1.50: Fixed Main Lugs Load Centers (Accepts Only HOM Plug-on Circuit Breakers - Not compatible with HOM Plug-on Neutral Circuit Breakers) Main Wire Size Max. Max.
Homeline™ Load Centers Homeline Load Centers, Indoor, 1Ø 1 Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Table 1.
Homeline™ Load Centers Homeline Load Centers, Indoor, 1Ø Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Table 1.
Homeline™ Load Centers Homeline Load Centers, Rainproof, 1Ø 1 Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us HOM Standard Load Center Main Lugs, Fixed Mains (1Ø3W—120/240 Vac Rainproof—UL Listed LOAD CENTERS Table 1.58: Fixed Main Lugs Load Centers (Accepts Only HOM Plug-on Circuit Breakers - Not compatible with HOM Plug-on Neutral Circuit Breakers) Mains Rating Spaces Max. Single Pole Circuits [28] Max. Tandem Circuit Breakers Load Center Box, Interior and Cover Cat. No.
Value Packs www.se.com/us QO/Homeline Load Center Value Packs and Accessories Class 1130, 1170 / Refer to Catalog 1100CT0501 Spaces Max. 1P Circuits [1] Max. Tandem Circuit Breakers Load Center Box, Interior, Cover and Branch Circuit Breakers Cat. No.
1 QO/Homeline Load Center Value Packs and Accessories QO Load Center Accessories www.se.com/us Class 1130 / Refer to Catalog 1100CT0501 QO Load Center Accessories Table 1.65: QO Load Center Accessories LOAD CENTERS Retaining Kit for Breakers Used as Back-fed Mains Cover Sealing Strap Replacement Cover Directory Label Circuit Identification Stickers Description Secures circuit breaker to interior when used as a back-fed main.
Homeline Load Center Accessories www.se.
1 QO/Homeline Load Center Value Packs and Accessories Surge Protective Devices www.se.com/us Class 1130 / Refer to Catalog 1100CT0501 Surge Protective Devices (SPD) Table 1.68: Load Center and CSED Surge Protection Devices Description LOAD CENTERS Cat. No.
Indoor Enclosure Dimensions and Knockout Information QO/Homeline Load Center Dimensions Class 1130, 1170 / Refer to Catalog 1100CT0501 www.se.com/us Box No. 1 2 3 4 5 6 7 8 9 10 11 12 W in. 3.81 4.81 4.81 8.88 14.25 14.25 14.25 14.25 14.25 14.25 14.25 14.25 Dimensions H in. mm 6.72 171 9.30 236 9.30 236 12.57 319 14.92 379 17.92 455 20.92 531 26.04 661 29.86 758 33.78 858 37.98 965 39.37 1000 mm 97 122 122 226 362 362 362 362 362 362 362 362 D in. 3.00 3.19 3.19 3.80 3.75 3.75 3.75 3.75 3.75 3.75 3.
Indoor Enclosure Dimensions and Knockout Information QO/Homeline Load Center Dimensions 1 Class 1130, 1170 / Refer to Catalog 1100CT0501 www.se.com/us Table 1.71: Indoor Knockout Information and Enclosure Dimensions for Qwik Grip Loadcenters Dimensions W Box No. in. 14.25 14.25 14.25 14.25 14.25 14.25 LOAD CENTERS 7Q 8Q 9Q 10Q 11Q 12Q H mm 362 362 362 362 362 362 D in. 20.92 26.04 29.86 33.78 37.98 39.37 mm 531 661 758 858 965 1000 in. 3.75 3.75 3.75 3.75 3.75 3.
Rainproof, Dimensions, Knockouts and Bolt-on Hubs www.se.com/us QO/Homeline Load Center Dimensions Class 1130, 1170 / Refer to Catalog 1100CT0501 Enclosure Dimensions and Knockout Information LOAD CENTERS Table 1.72: Enclosure Dimensions Dimensions in. 6.52 4.88 8.88 14.75 14.75 14.75 14.75 14.75 14.75 4.56 6.92 7.56 9.62 6.92 14.75 8.88 8.55 8.88 1NM 1R [1] 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R H mm 166 124 226 375 375 375 375 375 375 116 176 192 244 176 375 226 217 226 in. 8.79 9.
Combination Service Entrance Devices Catalog Number Logic for CSEDs 1 Class 4119, 4120 www.se.com/us Catalog Number Logic for CSED Table 1.
Rainproof, Meter Mains Combination Service Entrance Devices Class 4119, 4120 www.se.com/us OH/UG Ring Type, HomelineTM Surface Mount Only 125 A 200 A 200 A 50 A 100 A — — — — — — — — — — — — — — — — — — — — B A 4–1/0 4–250 A 4–250 (2)8–2/0 27, 20 A 4–250 (2)8–2/0 27, 28 — — — — A 6–2/0 6–2/0 31, 24 — — — — A–L 4–250 8–2/0 40, 10 110 A — — — — A or B300 6–2/0 6–2/0 37, 20 200 A [6] — — — — A–L 4–250 8–2/0 47, 10 A–L 4–250 8–2/0 51, 10 2P Circuits (Max.
Combination Service Entrance Devices Rainproof, Meter Mains 1 Class 4119, 4120 www.se.
Rainproof, All-In-Ones, 100 to 225 A Maximum Combination Service Entrance Devices Class 4120 www.se.com/us • • • UL Listed, suitable only for use as service equipment Meets EUSERC standards • • Service disconnect(s) are supplied factory-installed, except where noted Semiflush-reverse design available, supplied with load center (indoor access) • • Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires.
Combination Service Entrance Devices 1 Rainproof, Meter Mains and All-In-Ones, 300–400 A Class 4119, 4120 www.se.com/us Meter Mains and All-in-Ones (300–400 A Devices) • • • Meter Mains and All-in-Ones Ring or ringless type meter socket designs available UL Listed, suitable only for use as service equipment Meets EUSERC standards where indicated.
Circuit Breakers for CSEDs Combination Service Entrance Devices Class 4119, 4120 www.se.com/us Table 1.
Combination Service Entrance Devices Accessories and Hubs for CSEDs Class 4119, 4120 1 www.se.com/us Accessories and Hubs for CSEDs Table 1.82: Accessories LOAD CENTERS Description Generator Kit: Interlocks main service disconnect and generator circuit breaker (order separately).
Dimensions for CSEDs Combination Service Entrance Devices Class 4119, 4120 www.se.com/us Table 1.84: Knockouts 28.28 “A” Hub 380 718 Symbol A B C D E F G H I J Conduit Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 (in.) ▲ Driphood supplied factory-installed and is required for surface mount installation. For semi-flush installation, remove driphood and install flange kit SC200F (order separately). ■ Unit supplied with blank top endwall (factory-installed) for surface mount installation.
RC/QC Solar Ready CSEDs 1 Rainproof, Meter Mains and All-In-Ones, 150 to 200 A Maximum www.se.com/us Class 4120 Meter Mains and All-In-Ones • • • • • • • Service disconnect(s) are supplied factory-installed, except where noted Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires All devices have a 3" KO in the bottom endwall Provisions for Field Installed CTs All Devices Solar Ready kit SR69064A fits All Devices Below, order from Table 1.
Rainproof, Meter Mains and All-In-Ones, 125 to 225 A Maximum Homeline Solar Ready PoN CSEDs Class 4120 www.se.
Wiser Energy™ Wiser Energy™ Smart Home 1 Class 4120 www.se.com/us Wiser Energy™ Smart Home LOAD CENTERS Wiser Energy from Square D is an integral part of any smart home. With Wiser Energy, you can give your home a voice. It helps you keep tabs on your home by notifying you when devices are on or off in the home, and monitors home energy usage in real time, for a safer and more efficient home.
Enclosed Devices Service Entrance Devices www.se.
Enclosed Devices Non-Service Entrance Devices Class 1130 / Refer to Catalog 1100CT0501 1 www.se.com/us 1Ø3W—120/240 Vac—240 Vac—UL Listed Table 1.94: Enclosed Molded Case Switch, Switch Included, Does NOT provide overcurrent protection LOAD CENTERS Ampere Rating General Purpose Rainproof 240 Vac 60 A [5] [6] QO260NATS QO200TR QO200TRNM QO260NATR Box. No. [4] 2, 9R [7] 1NM 1R 120/240 Vac 100 A [8] QO2000NS QO2000NRB 13, 10R Service Table 1.
Enclosed Devices Non-Service Entrance Devices www.se.com/us Class 1130 / Refer to Catalog 1100CT0501 Table 1.98: QOM2 Enclosures and QOM2 Circuit Breakers Service QOM22225NF/S Type 3R Rainproof Box No. [17] Ampere Rating QOM22225NRB 22, 16R 100 A 125 A 150 A 175 A 200 A 225 A 1 2P 240 Vac Maximum 22 k AIR Cat. No.[18] QOM2100VH QOM2125VH QOM2150VH QOM2175VH QOM2200VH QOM2225VH Cat. No.
Servicepak™ Power Outlet Panels 1 Class 1140 www.se.com/us Power Outlet Panels for Construction Sites T LOAD CENTERS T T 1C T T T T 2C T • • • • • • • 3C T T T Provide temporary power at construction sites. Each receptacle protected by QO-GFI circuit breaker in compliance with NEC® requirements. Each enclosure is rainproof. 10 kA short circuit current rating. UL Listed as suitable for use as temporary site service equipment. Provided with neutral bonding provisions.