Square-Duct™ Wireways Catalog 5100CT0101R06/11 2011 Class 5100 CONTENTS Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page Wireway Offerings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 General Purpose—NEMA Type 1 Painted Wireway . . . . . . . . . . . . . . . . . . 5 Oiltight—NEMA Type 12 Wireway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Raintight—NEMA Type 3R Wireway . . . . . . .
Square-Duct™ Wireways Wireway Offerings Wireway Offerings General Purpose—NEMA Type 1 Painted Wireway on page 5 Oiltight—NEMA Type 12 Wireway on page 13 Raintight—NEMA Type 3R Wireway on page 23 Raintight—NEMA Type 3R Trough on page 27 © 1986—2011 Schneider Electric All Rights Reserved 3 ™ 08/2011
Square-Duct™ Wireways Wireway Offerings Application and General Information Wireway is designed to protect electrical wiring from dust, dirt, oil, and water. It is also designed to carry electrical feeders, branch circuits, and other groups of conductors. Most sections and fittings are completely open on one side so wires and cables can be laid in along an entire wireway run. No pulling through of wires or cables is required with most designs.
Square-Duct™ Wireways General Purpose—NEMA Type 1 Painted Wireway General Purpose—NEMA Type 1 Painted Wireway Application General Purpose—NEMA Type 1 Painted Wireway is designed to protect electrical wiring from dust, dirt, oil, and water. All sections and fittings are completely open on one side so wires and cables can be laid in along an entire wireway run. No pulling through of wires or cables is required with this design.
Square-Duct™ Wireways General Purpose—NEMA Type 1 Painted Wireway Construction General Purpose—NEMA Type 1 Painted Wireway construction consists of: • 16 gauge galvanized steel covers and bodies in sizes: — 2.50 in. x 2.50 in. (64 mm x 64 mm) — 4.00 in. x 4.00 in. (102 mm x 102 mm) — 6.00 in. x 6.00 in. (152 mm x 152 mm) • 14 gauge galvanized steel covers and bodies in sizes: — 8.00 in. x 8.00 in. (203 mm x 203 mm) — 10.00 in. x 10.00 in. (254 mm x 254 mm) — 12.00 in. x 12.00 in.
Square-Duct™ Wireways General Purpose—NEMA Type 1 Painted Wireway Industry Standards General Purpose—NEMA Type 1 Painted Wireway is in compliance with the following industry standards: • • • • UL Listed to File E27524, 870 NEMA/EEMAC Type 1 CSA Listed to File LL42184, Type 1 IEC 60529, IP30 Accessories Touch-up paint (order no.
Square-Duct™ Wireways General Purpose—NEMA Type 1 Painted Wireway Catalog Numbers—Type LDB ANSI 49 Gray Polyester Powder Finish Components 2.50 x 2.50 in. (64 x 64 mm) 4.00 x 4.00 in. (102 x 102 mm) 6.00. x 6.00 in. (152 x 152 mm) Catalog Number Catalog Number Catalog Number With Without With Without With Without Knockouts Knockouts Knockouts Knockouts Knockouts Knockouts 8.00 x 8.00 in. 10.00 x 10.00 in. 12.00 x 12.00 in.
Square-Duct™ Wireways General Purpose—NEMA Type 1 Painted Wireway Number of Knockouts for Varying Lengths of 2.5-inch, 4-inch, and 6-inch Wireways Number of Knockouts Catalog Number 0.50 in.–0.75 in. 1.00 in. –1.25 in. (13 mm–19 mm) (25 mm–32 mm) F LDB21KO 8 — 1.06 in. (27 mm) LDB41KO 4 4 1.62 in. (41 mm) LDB61KO 4 4 1.62 in. (41 mm) LDB22KO 16 — 1.06 in. (27 mm) LDB42KO 8 8 1.62 in. (41 mm) LDB62KO 8 8 1.62 in. (41 mm) LDB23KO 24 — 1.06 in. (27 mm) LDB43KO 12 12 1.62 in.
Square-Duct™ Wireways General Purpose—NEMA Type 1 Painted Wireway This drawing illustrates how most of the General Purpose—NEMA Type 1 Painted Wireway sections and fittings could be used in an actual wireway run. The covers have been omitted to present the lay-in feature more clearly. Many different sections and fittings can be combined in any configuration desired. Straight Section Available in lengths from 1 ft (30 cm) to 10 ft (305 cm).
Square-Duct™ Wireways General Purpose—NEMA Type 1 Painted Wireway 15.00 in. (381 mm) Telescope Fitting Length is easily adjustable to approximately 12.00 in. (305 mm). No cutting or welding required. Open Adapter Panel Adapter Used with the 90° Elbow-Tee-Cross fitting to permit a run directly up or down. A flanged fitting which allows the wireway to be securely connected to an enclosure. 1.38 in. (35 mm) on: 2.00 in. (51 mm) on: 2.00 in. x 200 in. (51 mm x 51 mm) 8.00 in. x 8.99 in.
Square-Duct™ Wireways General Purpose—NEMA Type 1 Painted Wireway 12 08/2011 ™ © 1986—2011 Schneider Electric All Rights Reserved
Square-Duct™ Wireways Oiltight—NEMA Type 12 Wireway Oiltight—NEMA Type 12 Wireway Application Oiltight—NEMA Type 12 Wireway is designed to protect electrical wiring from dust, dirt, oil, and water. All straight sections and fittings are completely open on one side so wires and cables can be laid in along an entire wireway run. No pulling through of wires or cables is required with this design.
Square-Duct™ Wireways Oiltight—NEMA Type 12 Wireway Finish Oiltight—NEMA Type 12 Wireway is furnished in ANSI 49 gray polyester powder finish inside and out over phosphatized surfaces. The sealing plate and quick-release latches are zinc plated with yellow chromate coating.
Square-Duct™ Wireways Oiltight—NEMA Type 12 Wireway Catalog Numbers—Type LJB Lay-in‡ 2.50 x 2.50 in. (64 x 64 mm) 4.00 x 4.00 in. (102 x 102 mm) 6.00 x 6.00 in. (152 x 152 mm) 8.00 x 8.00 in. (203 x 203 mm) 12.00 x 6.00 in. (305 x 152 mm) 1 in. Nipple LJB201 LJB401 LJB601 — — 2 in. Nipple LJB202 LJB402 LJB602 — — 3 in. Nipple LJB203 LJB403 LJB603 — — 6 in.
Square-Duct™ Wireways Oiltight—NEMA Type 12 Wireway Dimensions for Wireway Components (See pages 17–21) AxB IN (mm) 2.50 x 2.50 (64 x 64) C IN IN IN IN (mm) (mm) (mm) (mm) D IN (mm) IN (mm) E G H J K M N P R S T U IN IN IN IN IN IN IN IN IN IN IN IN IN (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 6.00 12.00 24.00 48.00 60.00 120.00 3.88 (152) (305) (610) (1219) (1524) (3048) (99) 3.88 (99) 8.50 4.25 (216) (108) 2.00 (51) 4.25 12.00 10.25 4.
Square-Duct™ Wireways Oiltight—NEMA Type 12 Wireway This drawing illustrates how most of the Oiltight—NEMA Type 12 Wireway sections and fittings could be used in an actual wireway run. The covers have been omitted to present the lay-in feature more clearly. Many different sections and fittings can be combined in any configuration desired. 9.00 12.00 in. (305 mm) in. (22 9 mm ) 15.00 to in. (38 1 mm ) Straight Section Available in lengths from 1 ft (30 cm) to 10 ft (305 cm).
Square-Duct™ Wireways Oiltight—NEMA Type 12 Wireway 10.25 in. 1.00 in. (260 mm) (25 mm) to 7.00 in. (178 mm) Gasket Panel Flange Lay-In Telescope Fitting Junction Box Cross The junction box has a removable panel on which terminal blocks and other components may be mounted. Panel dimensions are: Length is easily adjustable from 1.00 in. (25 mm) to 7.00 in. (178 mm). No cutting or welding required. 8.75 in. x 6.88 in. (222 mm x 175 mm) for F-22LJ 10.75 in. x 8.88 in.
Square-Duct™ Wireways Oiltight—NEMA Type 12 Wireway 90° Elbow Outside Top Opening This elbow fitting allows a vertical drop to equipment below at a 90° corner while maintaining the top opening lay-in feature. 45° Elbow Outside Opening Similar to the 90° elbows in design and function, but is used where a 45° angle is needed. Nipple Available in lengths of 1.00 in. (25 mm), 2.00 in. (51 mm), 3.00 in. (76 mm), and 6.00 in. (152 mm).
Square-Duct™ Wireways Oiltight—NEMA Type 12 Wireway in. 12.00 ) mm (305 Box Connector Closing Plate When wireway enters an enclosure, a box connector should be used on the inside of the enclosure to ensure a tight seal. Clockwise Transposition Section These fittings are used when it is necessary to rotate the open side of the wireway run by 90 ° and still retain the lay-in feature. Used to seal the end of a wireway section or run. 12.0 (305 0 in.
Square-Duct™ Wireways Oiltight—NEMA Type 12 Wireway 4.00 in. (102 mm) Reducer Connector This fitting permits the lay-in feature to be retained when reducing to a smaller wireway size. Extra Connector Kit When joining a lay-in section or fitting to a closure plate, a box connector, a non-lay-in cut-off fitting, or any similar non-lay-in section or fitting, a 90° angle This hinged sealing plate permits quick and easy access to sealing plate is required at each junction.
Square-Duct™ Wireways Oiltight—NEMA Type 12 Wireway 22 08/2011 ™ © 1986—2011 Schneider Electric All Rights Reserved
Square-Duct™ Wireways Raintight—NEMA Type 3R Wireway Raintight—NEMA Type 3R Wireway Application Raintight—NEMA Type 3R Wireway is designed to protect electrical wiring in outdoor installations against rain, sleet, and snow or indoors against dripping water. All sections and fittings are completely open on one side so wires and cables can be laid in along an entire wireway run. No pulling through of wires or cables is required with this design.
Square-Duct™ Wireways Raintight—NEMA Type 3R Wireway Finish Raintight—NEMA Type 3R Wireway is furnished in ANSI 49 gray polyester powder finish over galvanized steel. Industry Standards Raintight—NEMA Type 3R Wireway is in compliance with the following industry standards: • • NEMA/EEMAC Type 3R IEC 60529, IP32 Catalog Numbers—Raintight Wireway Description 4.00 in. x 4.00 in. 6.00 in. x 6.00 in. 8.00 in. x 8.00 in.
Square-Duct™ Wireways Raintight—NEMA Type 3R Wireway Dimensions for Wireway Components (See page 26) AxB C G K N O P Q S T U V W IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) 4.00 x 4.00 (102 x 102) 12.00 (305) 60.00 (1524) 120.00 (3048) 16.00 16.00 13.00 16.00 10.00 10.00 9.50 4.50 1.25 5.00 5.00 (406) (406) (330) (406) (254) (254) (241) (114) (31) (127) (127) 6.00 x 6.
Square-Duct™ Wireways Raintight—NEMA Type 3R Wireway 30 Straight Section Available in lengths from 1 ft (30 cm) to 10 ft (305 cm). 90° Elbow-Tee-Cross Use when there are four branches. It can be used as a 90° Elbow or a 90° Flush Tee by adding Closure Plates. 1.28 in. (33 mm) 90° Flush Tee ˚ 30° Sweep Elbow Use wherever flush mounting against a vertical surface is required. When a large radius is needed, use this sweep elbow.
Square-Duct™ Wireways Raintight—NEMA Type 3R Trough Raintight—NEMA Type 3R Trough Application Raintight—NEMA Type 3R Trough is designed to protect electrical wiring in outdoor installations against rain, sleet, and snow or indoors against dripping water.
Square-Duct™ Wireways Raintight—NEMA Type 3R Trough C Catalog Numbers—Raintight Trough C A x B (below) (below) 4.00 x 4.00 in. (102 x 102 mm) 6.00 x 6.00 in. (152 x 152 mm) 1 ft RDB41 RDB61 — — — 2 ft RDB42 RDB62 RDB82 RDB102 RDB122 RDB123 Length 8.00 x 8.00 in. (203 x 203 mm) 10.00 x 10.00 in. (254 x 254 mm) 12.00 x 12.00 in.
Schneider Electric USA, Inc. 5375 College Corner Road Oxford, OH 45056 USA 1-888-778-2733 www.schneider-electric.us Square D™ and Schneider Electric™ are trademarks or registered trademarks of Schneider Electric. Other trademarks used herein are the property of their respective owners.