Brochure

18-62
© 2019 Schneider Electric
All Rights Reserved
Dimensions
TeSys™ F Non-Reversing Contactors
www.se.com/us
Refer to Catalog MKTED210011EN
TeSys™ F Contactors, Dimensions
All dimensions shown in mm.
To convert to inches, divide by 25.4.
LC1F115 to F330
L
c
b
b2
==
X1
X1
(1) Protective cover
Type LA9F70•
(1)
S
s1
Q P P
Q1
a
f
M
(2)
(2) Optimal terminal shroud
Z
=
=G1
G Y
J
J1
b1
==
Table 18.197: LC1F115–F330 Dimensions
LC1
F115 F150 F185 F225 F265 F330
3-Pole 4-Pole 3-Pole 4-Pole
3-
Pole
4-
Pole
3-
Pole
4-
Pole
3-
Pole
4-
Pole
3-
Pole
4-
Pole
a 163.5 200.5 163.5 200.5 168.5 208.5 168.5 208.5 201.5 243.5 213 261
b 162 162 170 170 174 174 197 197 203 203 206 206
b1 137 137 137 137 137 137 137 137 145 145 145 145
b2 265 265 301 301 305 305 364 364 370 370 375 375
c
165 [2] 165 [2] 165 [2] 165 [2]
176 176 181 181 207 207 219 219
f 131 131 131 131 130 130 130 130 147 147 147 147
G 106 143 106 143 111 151 111 151 142 190 154.5 202.5
G1 80 80 80 80 80 80 80 80 96 96 96 96
J 106 106 106 106 106 106 106 106 106 106 106 106
J1 120 120 120 120 120 120 120 120 120 120 120 120
L 107 107 107 107 113.5 113.5 113.5 113.5 141 141 145 145
M 147 147 150 150 154 154 172 172 178 178 181 181
P 37 37 40 40 40 40 48 48 48 48 48 48
Q
29.5 29.5 26.5 26 29 29 21 17 39 34 43 43
Q1
60 60 57.5 55.5 59.5 59.5 51.5 47.5 66.5 66.5 74 74
S 15 15 20 20 20 20 25 25 25 25 25 25
S1 27 27 34 34 34 34 44.5 44.5 38 38 44.5 44.5
Y 44 44 44 44 44 44 44 44 38 38 38 38
Z 13.5 13.5 13.5 13.5 13.5 13.5 13.5 13.5 21.5 21.5 20.5 20.5
f = minimum distance required for coil removal.
Table 18.198: LC1F115–F330 Voltage
200 to 500 V 600 to 1000 V
LC1F115, F150
10 15
LC1F185 10 15
LC1F225, F265
10 15
LC1F330 10 15
X1: Minimum clearance according to the operational voltage and the breaking capacity.
LC1F400 to F500
2.20
56
X1
c
L
8.23
209
b
b2
==
(1)
(1) Protective cover
S
1.49
38
M10 X 30 dia.
Q
P P
Q1
a
f
M
8 X 8.5 dia.
G
.92
23.5
G1
J
4.7
120
7.09
180
=
=
=
=
Table 18.199: LC1F400–F500 Dimensions
LC1
F400 F500
2-Pole 3-Pole 4-Pole 2-Pole 3-Pole 4-Pole
a 213 213 261 233 233 288
b 206 206 206 238 238 238
b2 375 375 375 400 400 400
c 213 213 213 226 226 226
f 119 119 119 141 141 141
G [3]
80 80 80 80 80 140
G min. 66 66 66 66 66 66
G max. 102 102 150 120 120 175
G1 [3]
170 170 170 170 170 230
G1 min. 156 156 156 156 156 156
G1 max. 192 192 240 210 210 265
J 19.5 19.5 67.5 39.5 39.5 34.5
L 145 145 145 146 146 146
M 181 181 181 208 208 208
P 48 48 48 55 55 55
Q
69 43 43 76 46 46
Q1
96 74 74 102 77 77
S 25 25 25 30 30 30
f = Minimum distance required for coil removal.
Table 18.200: LC1F400–F500 Voltage
200 to 500 V 600 to 1000 V
LC1F400 15 20
LC1F500 15 20
X1: Minimum clearance according to the operational voltage and the breaking capacity.
18
CONTACTORS AND STARTERS-IEC
[2] +6 mm with time delay block (for F115 and F150).
[3] Supplied