Brochure

18-58
© 2019 Schneider Electric
All Rights Reserved
Wiring Systems Splitter Boxes, Power Connections, and
Accessories
www.se.com/us
Refer to Catalog MKTED210011EN
Splitter Boxes, Power Connections and Accessories
APP2R4H1
Table 18.183: Splitter Boxes [1]
Description
Type of Control-
Command
Connection on
Control System Side
No. of I/O per
Starter
No. of
Starters
per Unit
Catalog Number
50 A power splitter box
2 LAD322
4 LAD324
50 A power and control splitter box
1 x HE10, 8 I / 8 O
1 I / 1 O 4 APP2R4H1
1 x HE10, 16 I and
1 x HE10, 8 O
2 I / 1 O 4 APP2R4H2
via module APP1C●●● [2]
2 APP2R2E
4 APP2R4E
AS-Interface
2 I / 1 O 2 APP2R2AS
1 I / 1 O 4 APP2R4AS
LAD35 LAD3B
LAD33
APP2D1●
Table 18.184: Power Connection Components for One Starter
Description
Kit Consists Of:
Catalog Number
Assembly and power connection kit
One LAD31 plate for GV2ME and two LAD34 power
connection modules
LAD351
Reversing kit [3]
One set of bus bars and one mechanical interlock LAD32
Table 18.185: Power Connection Accessories for One Starter
Description
Max.
Connection
Cross-Section
Use
Catalog Number
Upstream terminal block (50 A
max)
16 mm
2
(6 AWG)
Power supply for one or two power
splitter boxes
LAD3B
Downstream terminal block (50 A
max)
6 mm
2
(10 AWG)
Connection of motor cables LAD331
Table 18.186: Control Connection Module for One Starter
Description
D-Line
Coil Voltage
Type of Coil
Control
Relay
Type of Starter Catalog Number
Control connection module
(integrating contact block
GVAE20)
12–240 Vac or
24–125 Vdc
Electromechanical
[4]
Non-reversing
APP2D1
Reversing
APP2D2
24–48 Vdc
Without relay [5]
Non-reversing
APP2D1D
Reversing
APP2D2D
Table 18.187: Spare or Replacement Parts
Description
Type of Control-
Command
Connection on Control
System Side
No. of
I/O per
Starter
No. of
Starters
Sold in
Lots of
Catalog Number
Plate for mounting a GV2ME
manual starter
1 10 LAD311
Power connection module 1 10 LAD341
Control-command splitter box
(single, for mounting on a power
splitter box)
1 x HE10, 8 I / 8 O
1 I / 1 O 4 1 APP2R4H3
1 x HE10, 16 I, and
1 x HE10, 8 O
2 I / 1 O 4 1 APP2R4H4
Per module APP1C●●●
[2]
2 1 APP2R2C
4 1 APP2R4C
AS-Interface
2 I / 1 O 2 1 APP2R2A
1 I / 1 O 4 1 APP2R4A
Replacement electromechanical relay (for control connection
module)
1 10 APP2ER
18
CONTACTORS AND STARTERS-IEC
[1] A total of up to eight starters is permissible after extensions. Use multiple quantities of the same catalog number to create the desired line-up.
[2] Connection to an APP1C••• module via APP2CX adapter (LAD35).
[3] To create a TeSys D reverser, use two LC1D contactors, one assembly and power connection kit, and one reversing kit.
[4] Relay supplied mounted on the front panel of the control connection.
[5] The use of TeSys D low consumption contactors is recommended.
9/13/2019