Brochure
© 2019 Schneider Electric
All Rights Reserved
18-53
www.se.com/us
TeSys™ D AC Coils
Replacement Parts
Refer to Catalog MKTED210011EN
TeSys™ D—AC Coils
LX1D6
Table 18.173: For Old D2 Style LC1D40, D50, D65, D80, and D95; For TeSys D LC1D40A, D50A, D65A, DT60A, and DT80A; For TeSys D
LC1D115 and D150
For Old D2 Style LC1D40, D50, D65, D80, D95 For TeSys D LC1D40A, D50A, D65A, DT60A, DT80A For TeSys D LC1D115, D150
Rated
Nominal
Voltage, V
Catalog
Number
50 Hz
Catalog
Number
60 Hz
Catalog
Number
50/60 Hz
Rated
Nominal
Voltage, V
Catalog
Number
50 Hz
Catalog
Number
60 Hz
Catalog
Number
50/60 Hz
Rated
Nominal
Voltage, V
Catalog
Number
50 Hz
Catalog
Number
60 Hz
Catalog
Number
50/60 Hz
24 LX1D6B5 LX1D6B6 LX1D6B7 12 LXD3J5 — — 24 LX1D8B5 LX1D8B6 LX1D8B7
32 LX1D6C5 — — 24 — — LXD3B7 32 LX1D8C5 — LX1D8C7
42 LX1D6D5 — LX1D6D7 32 — — LXD3C7 42 LX1D8D5 — LX1D8D7
48 LX1D6E5 LX1D6E6 LX1D6E7 42 — — LXD3D7 48 LX1D8E5 LX1D8E6 LX1D8E7
110 LX1D6F5 LX1D6F6 LX1D6F7 48 — — LXD3E7 110 LX1D8F5 LX1D8F6 LX1D8F7
120 — LX1D6G6 LX1D6G7 100 — — LXD3K7 115 LX1D8FE5 — LX1D8FE7
127 LX1D6G5 — — 110 — — LXD3F7 120 — LX1D8G6 LX1D8G7
208 — LX1D6L6 LX1D6LE7 115 — — LXD3FE7 127 LX1D8FC5 — LX1D8FC7
220 LX1D6M5 LX1D6M6 LX1D6M7 120 — — LXD3G7 208 — LX1D8L6 LX1D8L7
230 LX1D6P5 — LX1D6P7 127 — — LXD3FC7 220/230 LX1D8M5 LX1D8M6 LX1D8M7
240 LX1D6U5 LX1D6U6 LX1D6U7 200 — — LXD3L7 230 LX1D8P5 — LX1D8P7
256 LX1D6W5 — — 208 — — LXD3LE7 240 LX1D8U5 LX1D8U6 LX1D8U7
277 — LX1D6W6 — 220 — — LXD3M7 277 — LX1D8W6 LX1D8W7
380
LX1D6Q5 LX1D6Q6 LX1D6Q7
230 — — LXD3P7 380/400
LX1D8Q5 LX1D8Q6 LX1D8Q7
400 LX1D6V5 — LX1D6V7 240 — — LXD3U7 400 LX1D8V5 — LX1D8V7
415 LX1D6N5 — LX1D6N7 277 — — LXD3W7 415 LX1D8N5 — LX1D8N7
440 LX1D6R5 LX1D6R6 LX1D6R7 380 — —
LXD3Q7
440 LX1D8R5 LX1D8R6 LX1D8R7
480 — LX1D6T6 — 400 — — LXD3V7 480 — LX1D8T6 LX1D8T7
500 LX1D6S5 — — 415 — — LXD3N7 500 LX1D8S5 — LX1D8S6
575 — LX1D6S6 — 440 — — LXD3R7
For old style and new TeSys style contactors where the
catalog number may or may not include the auxiliary contact
arrangement.
600 — LX1D6X6 — 480 — — LXD3T7
660 LX1D6Y5 — — 500 — — LXD3S7
For old style and new TeSys style contactors where the
catalog number may or may not include the auxiliary
contact arrangement.
575 — — LXD3SC7
600 — — LXD3X7
660 — — LXD3YC7
690 — — LXD3Y7
Specification
50 Hz 60 Hz 50/60 Hz
Specification
50 Hz 60 Hz 50/60 Hz
Specification
50 Hz 60 Hz 50/60 Hz
Average consumption Average consumption Average consumption
-inrush
(inductance 0.75)
200 VA 220 VA 245 VA -inrush
(inductance 0.3)
160 VA 140 VA 140 VA
(Inductance: 0.9)
-inrush
(inductance 0.8)
300 VA 300 VA 350 VA
(Inductance: 0.9)
-sealed
(inductance 0.3)
20 VA 22 VA 26 VA -sealed
(inductance 0.3)
7.0 VA 7.5 VA 7.5 VA
(Inductance: 0.9)
-sealed
(inductance 0.3)
22 VA 22 VA 18 VA
(Inductance: 0.9)
Operating range Operating range Operating range
at θ ≤ 55 °C / 131 °F
80–110% of
nominal voltage
85–110% of
nominal voltage
at θ ≤ 55 °C / 131 °F
85–110% of
nominal voltage
80–115% of
nominal voltage
at θ ≤ 55 °C / 131 °F
85–110% of
nominal voltage
80–115% of
nominal voltage
Table 18.174: TeSys™ F—AC Coils (For LC1F115, F150, F185, F225, F265, F330, F400, F500, F630, F780, and F800)
Device
Type
Hz
Catalog
Number
Catalog Number Suffix[2]
24 V 48 V 110 V 120 V 208 V 220 V 240 V 277 V 380 V 415 V 440 V 480 V 600 V
F115–F150 40–400 LX9FF● — 048 110 127 200 220 220 260 380 415 415 500 —
F185, F225
40–400 LX9FG● — 048 110 127 200 220 220 260 380 415 415 500 —
F265–F330
40–400 LX1FH● 0242 0482 1102 1272 2002 2202 2402 2772 3802 3802 4402 5002 6002
40–400 LX9FH● — 0482 1102 1272 2002 2202 2402 2772 3802 3802 . . . 5002 —
F400
40–400 LX1FJ● — 048 110 127 200 220 240 280 380 415 415 500 600
40–400
LX9FJ● [3]
910 917 925 925 930 931 932 932 936 936 937 937
— [4]
F500
40–400 LX1FK● — 048 110 127 200 220 240 280 380 415 415 500 600
40–400
LX9FK● [3]
910 917 925 925 930 931 932 932 936 936 937 937
— [4]
F630
40–400 LX1FL● — 048 110 110 200 220 220 260 380 415 415 415 600
40–400
LX9FL● [3]
910 917 924 925 930 930 931 932 935 936 936 937
— [4]
F780 [5]
40–400 LX1FX● — — 110 110 200 220 220 280 380 415 415 415 —
F800 50/60
LX4F8● [3]
— — FW FW — MW MW —
QW
— — — —
F1400–F2100 40–400
LX1FK● [3]
— — 065 070 — 110 127 140 200 220 220 — —
18
CONTACTORS AND STARTERS-IEC
[2] Complete the catalog number by adding the suffix (for example, LX1FF024).
[3] Also requires rectifier DR5TE4U for 110–240 V coils, DR5TE4S for 380–440 V coils.
[4] The 600 V coils for the F400, F500 and F630 do not include an auxiliary contact for holding circuits. If required, select appropriate contacts from page 18-14.
[5] LC1F780 contactors operate with 2 coils as a set. The LX1FX● part number includes both coils.
9/13/2019