Brochure

© 2019 Schneider Electric
All Rights Reserved
18-53
www.se.com/us
TeSys™ D AC Coils
Replacement Parts
Refer to Catalog MKTED210011EN
TeSys™ D—AC Coils
LX1D6
Table 18.173: For Old D2 Style LC1D40, D50, D65, D80, and D95; For TeSys D LC1D40A, D50A, D65A, DT60A, and DT80A; For TeSys D
LC1D115 and D150
For Old D2 Style LC1D40, D50, D65, D80, D95 For TeSys D LC1D40A, D50A, D65A, DT60A, DT80A For TeSys D LC1D115, D150
Rated
Nominal
Voltage, V
Catalog
Number
50 Hz
Catalog
Number
60 Hz
Catalog
Number
50/60 Hz
Rated
Nominal
Voltage, V
Catalog
Number
50 Hz
Catalog
Number
60 Hz
Catalog
Number
50/60 Hz
Rated
Nominal
Voltage, V
Catalog
Number
50 Hz
Catalog
Number
60 Hz
Catalog
Number
50/60 Hz
 24 LX1D6B5 LX1D6B6 LX1D6B7 12 LXD3J5  24 LX1D8B5 LX1D8B6 LX1D8B7
 32 LX1D6C5 24 LXD3B7  32 LX1D8C5 LX1D8C7
 42 LX1D6D5 LX1D6D7 32 LXD3C7  42 LX1D8D5 LX1D8D7
 48 LX1D6E5 LX1D6E6 LX1D6E7 42 LXD3D7  48 LX1D8E5 LX1D8E6 LX1D8E7
110 LX1D6F5 LX1D6F6 LX1D6F7 48 LXD3E7 110 LX1D8F5 LX1D8F6 LX1D8F7
120 LX1D6G6 LX1D6G7 100 LXD3K7 115 LX1D8FE5 LX1D8FE7
127 LX1D6G5 110 LXD3F7 120 LX1D8G6 LX1D8G7
208 LX1D6L6 LX1D6LE7 115 LXD3FE7 127 LX1D8FC5 LX1D8FC7
220 LX1D6M5 LX1D6M6 LX1D6M7 120 LXD3G7 208 LX1D8L6 LX1D8L7
230 LX1D6P5 LX1D6P7 127 LXD3FC7 220/230 LX1D8M5 LX1D8M6 LX1D8M7
240 LX1D6U5 LX1D6U6 LX1D6U7 200 LXD3L7 230 LX1D8P5 LX1D8P7
256 LX1D6W5 208 LXD3LE7 240 LX1D8U5 LX1D8U6 LX1D8U7
277 LX1D6W6 220 LXD3M7 277 LX1D8W6 LX1D8W7
380
LX1D6Q5 LX1D6Q6 LX1D6Q7
230 LXD3P7 380/400
LX1D8Q5 LX1D8Q6 LX1D8Q7
400 LX1D6V5 LX1D6V7 240 LXD3U7 400 LX1D8V5 LX1D8V7
415 LX1D6N5 LX1D6N7 277 LXD3W7 415 LX1D8N5 LX1D8N7
440 LX1D6R5 LX1D6R6 LX1D6R7 380
LXD3Q7
440 LX1D8R5 LX1D8R6 LX1D8R7
480 LX1D6T6 400 LXD3V7 480 LX1D8T6 LX1D8T7
500 LX1D6S5 415 LXD3N7 500 LX1D8S5 LX1D8S6
575 LX1D6S6 440 LXD3R7
For old style and new TeSys style contactors where the
catalog number may or may not include the auxiliary contact
arrangement.
600 LX1D6X6 480 LXD3T7
660 LX1D6Y5 500 LXD3S7
For old style and new TeSys style contactors where the
catalog number may or may not include the auxiliary
contact arrangement.
575 LXD3SC7
600 LXD3X7
660 LXD3YC7
690 LXD3Y7
Specification
50 Hz 60 Hz 50/60 Hz
Specification
50 Hz 60 Hz 50/60 Hz
Specification
50 Hz 60 Hz 50/60 Hz
Average consumption Average consumption Average consumption
-inrush
(inductance 0.75)
200 VA 220 VA 245 VA -inrush
(inductance 0.3)
160 VA 140 VA 140 VA
(Inductance: 0.9)
-inrush
(inductance 0.8)
300 VA 300 VA 350 VA
(Inductance: 0.9)
-sealed
(inductance 0.3)
20 VA 22 VA 26 VA -sealed
(inductance 0.3)
7.0 VA 7.5 VA 7.5 VA
(Inductance: 0.9)
-sealed
(inductance 0.3)
22 VA 22 VA 18 VA
(Inductance: 0.9)
Operating range Operating range Operating range
at θ 55 °C / 131 °F
80–110% of
nominal voltage
85–110% of
nominal voltage
at θ 55 °C / 131 °F
85–110% of
nominal voltage
80–115% of
nominal voltage
at θ 55 °C / 131 °F
85–110% of
nominal voltage
80–115% of
nominal voltage
Table 18.174: TeSys™ F—AC Coils (For LC1F115, F150, F185, F225, F265, F330, F400, F500, F630, F780, and F800)
Device
Type
Hz
Catalog
Number
Catalog Number Suffix[2]
24 V 48 V 110 V 120 V 208 V 220 V 240 V 277 V 380 V 415 V 440 V 480 V 600 V
F115–F150 40–400 LX9FF●  048  110  127  200  220  220  260  380  415  415  500
F185, F225
40–400 LX9FG●  048  110  127  200  220  220  260  380  415  415  500
F265–F330
40–400 LX1FH● 0242 0482 1102 1272 2002 2202 2402 2772 3802 3802 4402 5002 6002
40–400 LX9FH● 0482 1102 1272 2002 2202 2402 2772 3802 3802 . . . 5002
F400
40–400 LX1FJ●  048  110  127  200  220  240  280  380  415  415  500 600
40–400
LX9FJ● [3]
 910  917  925  925  930  931  932  932  936  936  937  937
[4]
F500
40–400 LX1FK●  048  110  127  200  220  240  280  380  415  415  500 600
40–400
LX9FK● [3]
 910  917  925  925  930  931  932  932  936  936  937  937
[4]
F630
40–400 LX1FL●  048  110  110  200  220  220  260  380  415  415  415 600
40–400
LX9FL● [3]
 910  917  924  925  930  930  931  932  935  936  936  937
[4]
F780 [5]
40–400 LX1FX●  110  110  200  220  220  280  380  415  415  415
F800 50/60
LX4F8● [3]
FW FW MW MW
QW
F1400–F2100 40–400
LX1FK● [3]
065 070 110 127 140 200 220 220
18
CONTACTORS AND STARTERS-IEC
[2] Complete the catalog number by adding the suffix (for example, LX1FF024).
[3] Also requires rectifier DR5TE4U for 110–240 V coils, DR5TE4S for 380–440 V coils.
[4] The 600 V coils for the F400, F500 and F630 do not include an auxiliary contact for holding circuits. If required, select appropriate contacts from page 18-14.
[5] LC1F780 contactors operate with 2 coils as a set. The LX1FX● part number includes both coils.
9/13/2019