Brochure

© 2019 Schneider Electric
All Rights Reserved
18-45
www.se.com/us
TeSys™ D Enclosed Combination Starters Motor Starters and Protectors
Refer to Catalog MKTED210011EN
Table 18.154: Enclosed Full Voltage Reversing Circuit Breaker Combination Starters[61]
Maximum Three-Phase Horsepower Ratings
Auxiliary Contacts
Each Contactor
Circuit Breaker
Maximum
Current Rating
Current
Rating of
Contactor
Catalog Number [62][63]
200 V 230 V 460 V 575 V N.O. N.C.
Type 1 Type 12/3R
2 2 5 7.5 1 1 30 A  9 LE2D099E62O●●●● LE2D099E72O●●●●
3 3 7.5 10 1 1 30 A 12 LE2D129E62O●●●● LE2D129E72O●●●●
7.5 7.5 15 20 1 1 30 A 25 LE2D259E62O●●●● LE2D259E72O●●●●
10 10 20 25 1 1 50 A 32 LE2D329F62O●●●● LE2D329F72O●●●●
10 10 30 30 1 1 50 A 40 LE2D409F62O●●●● LE2D409F72O●●●●
15 15 40 40 1 1 100 A 50 LE2D509G62O●●●● LE2D509G72O●●●●
20 20 40 50 1 1 100 A 65 LE2D659G62O●●●● LE2D659G72O●●●●
25 30 60 60 1 1 150 A 80 LE2D809G62O●●●● LE2D809G72O●●●●
30 40 75 75 1 1 200 A 115 LE2D119H62O●●●● LE2D119H72O●●●●
40 50 100 100 1 1 200 A 150 LE2D159J62O●●●● LE2D159J72O●●●●
Table 18.155: Enclosed Full Voltage Non-Reversing Non-Fused Combination Starters
Maximum Three-Phase Horsepower Ratings
Auxiliary
Contacts
Current
Rating of
Contactor
Catalog Number
200 V 230 V 460 V 575 V N.O. N.C.
Type 1 Type 12/3R
2 2 5 7.5 1 1  9 LE1D096A62O●●●● LE1D096A72O●●●●
3 3 7.5 10 1 1 12 LE1D126A62O●●●● LE1D126A72O●●●●
5 5 10 15 1 1 18 LE1D186A62O●●●● LE1D186A72O●●●●
5 7.5 15 20 1 1 25 LE1D256A62O●●●● LE1D256A72O●●●●
7.5 10 20 25 1 1 32 LE1D326A62O●●●● LE1D326A72O●●●●
10 10 30 30 1 1 40 LE1D406A62O●●●● LE1D406A72O●●●●
Table 18.156: Enclosed Full Voltage Reversing Non-Fused Combination Starters
Maximum Three-Phase Horsepower Ratings
Aux. Contacts
Each Contactor
Current
Rating of
Contactor
Catalog Number
200 V 230 V 460 V 575 V N.O. N.C.
Type 1 Type 12/3R
2 2 5 7.5 1 1  9 LE2D096A62O●●●● LE2D096A72O●●●●
3 3 7.5 10 1 1 12 LE2D126A62O●●●● LE2D126A72O●●●●
5 5 10 15 1 1 18 LE2D186A62O●●●● LE2D186A72O●●●●
5 7.5 15 20 1 1 25 LE2D256A62O●●●● LE2D256A72O●●●●
7.5 10 20 25 1 1 32 LE2D326A62O●●●● LE2D326A72O●●●●
10 10 30 30 1 1 40 LE2D406A62O●●●● LE2D406A72O●●●●
TeSys D dimensions: page 18-71
18
CONTACTORS AND STARTERS-IEC
[61] Insta-kit design available in Type 1 and Type 12 enclosures only.
[62] Replace (••••) with the corresponding coil voltage code from Table 18.148 Voltage Codes for Enclosed Starters, page 18-42 followed by the corresponding O/L relay suffix number from
Table 18.149 Overload Relay Range, page 18-42.
[63] For a breaker size different from the ones proposed, specify your requirement using Table 18.145.
9/13/2019