Motor Starters and Protectors TeSys™ D Enclosed Starters
www.se.com/us
Refer to Catalog MKTED210011EN
Enclosed TeSys™ D Starters
LE1D093A62OB70
TeSys D enclosed full-voltage starters are available in Type 1 and Type 12/3R
enclosures. The enclosed TeSys D offer accepts standard TeSys D accessories and all
Insta-Kits control units and control power transformer kits. Standard capacity control
power transformers with built-in fuse block can be installed in the standard enclosure.
For extra capacity, please refer to your local distributor or Schneider Electric sales office.
Table 18.146: Insta-Kits for Enclosed Full Voltage Non-Reversing Starters
[46]
Max. Horsepower Ratings
Auxiliary Contacts On
Each Contactor
Current Rating
of Contactor
Catalog Number
[47][48]
Single-Phase
Three-Phase
120 V 240 V 208 V 230 V 460 V 575 V N.O. N.C.
Type 1 Type 12/3R
1/3 1 2 2 5 7.5 1 1 9 LE1D093A62O•••• LE1D093A72O••••
1/2 2 3 3 7.5 10 1 1 12 LE1D123A62O•••• LE1D123A72O••••
1 3 5 5 10 15 1 1 18 LE1D183A62O•••• LE1D183A72O••••
2 3 5 7.5 15 20 1 1 25 LE1D253A62O•••• LE1D253A72O••••
2 5 7.5 10 20 25 1 1 32 LE1D323A62O•••• LE1D323A72O••••
3 5 10 10 30 30 1 1 40 LE1D403A62O•••• LE1D403A72O••••
3 7.5 15 15 40 40 1 1 50 LE1D503A62O•••• LE1D503A72O••••
5 10 20 20 40 50 1 1 65 LE1D653A62O•••• LE1D653A72O••••
7.5 15 25 30 60 60 1 1 80 LE1D803A62O•••• LE1D803A72O••••
— — 30 40 75 75 1 1 115 LE1D113A62O•••• LE1D113A72O••••
— — 40 50 100 100 1 1 150 LE1D153A62O•••• LE1D153A72O••••
Table 18.147: Insta-Kits for Enclosed Full Voltage Reversing Starters[46]
Max. Horsepower Ratings
Auxiliary Contacts On
Each Contactor
Current Rating
of Contactor
Catalog Number
[49][48]
Single-Phase
Three-Phase
120 V 240 V 208 V 230 V 460 V 575 V N.O. N.C.
Type 1 Type 12/3R
1/3 1 2 2 5 7.5 1 1 9 LE2D093A62O•••• LE2D093A72O••••
1/2 2 3 3 7.5 10 1 1 12 LE2D123A62O•••• LE2D123A72O••••
1 3 5 5 10 15 1 1 18 LE2D183A62O•••• LE2D183A72O••••
2 3 5 7.5 15 20 1 1 25 LE2D253A62O•••• LE2D253A72O••••
2 5 7.5 10 20 25 1 1 32 LE2D323A62O•••• LE2D323A72O••••
3 5 10 10 30 30 1 1 40 LE2D403A62O•••• LE2D403A72O••••
3 7.5 15 15 40 40 1 1 50 LE2D503A62O•••• LE2D503A72O••••
5 10 20 20 40 50 1 1 65 LE2D653A62O•••• LE2D653A72O••••
7.5 15 25 30 60 60 1 1 80 LE2D803A62O•••• LE2D803A72O••••
— — 30 40 75 75 1 1 115 LE2D113A62O•••• LE2D113A72O••••
— — 40 50 100 100 1 1 150 LE2D153A62O•••• LE2D153A72O••••
Table 18.148: Voltage Codes for Enclosed Starters
Primary Voltage
24 120 208 220 240 480 600
Code B7 G7 L7 M7 U7 T7 X7
Table 18.149: Overload Relay Range (Select code
from below)
[50]
Code
Range
For use on
Contactors
01 0.1–0.16
D09–D32 [51]
02 0.16–0.25
D09–D32 [51]
03 0.25–0.40
D09–D32 [51]
04 0.40–0.63
D09–D32 [51]
05 0.63–1.0
D09–D32 [51]
06 1.0–1.6
D09–D32 [51]
07 1.6–2.5
D09–D32 [51]
08 2.5–4 D09–D32
10 4–6 D09–D32
12 5.5–8 D09–D32
13 9–13
D40, D50, D65
14 7–10 D09–D32
16 9–13 D12–D32
18 12–18
D40, D50, D65
21 12–18 D18–D32
22 16–24
D25–D32 [51]
18
CONTACTORS AND STARTERS-IEC
[46] Insta-kit design available in Type 1 and Type 12 enclosures only.
[47] To obtain a single phase non-reversing starter, change prefix LE1 to LES. (e.g., LE1D093A62O•••• becomes LESD093A62O••••). Price remains unchanged.
[48] Replace (••••) with the corresponding coil voltage code from Table 18.148 followed by the corresponding O/L relay suffix number from Table 18.149.
[49] To obtain a single phase non-reversing starter, change prefix LE2 to LER. (e.g., LE2D093A62O•••• becomes LERD093A62O••••). For use on single phase application, connect a power
cable between terminals T3 on O/L relay and L2 on contactor.
[50] If no overload relay is required, leave this portion of the catalog blank.
[51] Available for Class 10 only.