Brochure
18-4
© 2019 Schneider Electric
All Rights Reserved
Contactors and Overload Relays TeSys™ K Contactors and Overload Relays
www.se.com/us
Refer to Catalog MKTED210011EN
LP2K0910
Table 18.11: DC Operating Coils
Maximum Horsepower Ratings Maximum Current (A)
Continuous
Current Rating (A)
Type of
Connection
Auxiliary
Contacts
Catalog Number
[17][18][19][20]
Single-Phase
Three-Phase
Inductive AC3 Resistive AC1
115 V 230 V 200 V 230 V 460 V 575 V N.O. N.C.
1/2 1 1.5 1.5 3 3 6 20 10
Screw-clamp
1 — LP2K0610
— 1 LP2K0601
1/2 1.5 2 3 5 5 9 20 20
Screw-clamp
1 — LP2K0910
— 1 LP2K0901
1 2 3 3 7.5 10 12 20 20
Screw-clamp
1 — LP2K1210
— 1 LP2K1201
Table 18.12: Coil Voltage Codes for DC Contactors
Coil with integral suppression device available. Add 3 to the code required. Example: JD3.
[21]
Vdc 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250
Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD
Table 18.13: DC–Low Consumption Operating Coils (devices have built-in transient suppression)
Maximum Horsepower Ratings Maximum Current (A)
Continuous
Current Rating (A)
Type of
Connection
Auxiliary
Contacts
Catalog Number
[22][17][23][24]
Single-Phase
Three-Phase
Inductive AC3 Resistive AC1
115 V 230 V 200 V 230 V 460 V 575 V N.O. N.C.
1/2 1 1.5 1.5 3 3 6 20 10
Screw-clamp
1 — LP5K0610
— 1 LP5K0601
1/2 1.5 2 3 5 5 9 20 20
Screw-clamp
1 — LP5K0910
— 1 LP5K0901
1 2 3 3 7.5 10 12 20 20
Screw-clamp
1 — LP5K1210
— 1 LP5K1201
Table 18.14: Coil Voltage Codes for DC Contactors—Low Consumption[25]
Vdc 12 24 48 72
Code JW3 BW3 EW3 SW3
18
CONTACTORS AND STARTERS-IEC
[17] For spring terminal clamps, add a 3 before the coil voltage code (for example, LC2K06103G7). Spring terminal clamps reduce some of the HP and continuous current ratings of the TeSys K
contactors. For ratings, please refer to Table 18.1.
[18] For solder pin terminals, add a 5 before the coil voltage code (for example, LC2K09105B7).
[19] For slip-on terminals, add a 7 before the coil voltage code (for example, LC2K12107M7).
[20] Complete the catalog number with the coil voltage code from Table 18.12 (for example, LC2K0610BD).
[21] 3 W inrush.
[22] Complete the catalog number with the coil voltage code from (for example, LP4K09004BW3).
[23] For solder pin terminals, add a 5 before the coil voltage code (for example, LC1K090045B7).
[24] For slip-on terminals, add a 7 before the coil voltage code (for example, LC1K120047M7).
[25] 1.8 W inrush.
9/13/2019