Motor Circuit Protectors Motor Starters and Protectors
Refer to Catalog 0680CT1701
GV7AC01 GV7RE20
GV7AC021
GV7V01
GV7AP03
Table 18.138: GV7 Wiring Accessories
Description Application Catalog Number
Box Lugs
Sold in lots of 3 for GV7R●20–150 [43]
GV7AC021
Sold in lots of 3 for GV7R●220 [43]
GV7AC022
Phase Barriers, Bus Bars & Shrouds
Terminal Extension Kit
Increases center distance between phases to 45 mm
GV7AC03
Terminal Shroud Kit
Covers terminal connections for touch safe protection
GV7AC01
Phase Barriers
Provides maximum phase separation at connection
points
GV7AC04
Insulating Barriers Provides insulation between connectors and backplate
GV7AC05
Busbars and Covers
Connect to LC1F115–185 contactor GV7AC06
Connect to LC1F225–265 contactor GV7AC07
Operating Handles and Accessories
Black rotary operating handle with black legend plate (mounts directly on device)
GV7AP03
Red rotary operating handle with yellow legend plate (mounts directly on device)
GV7AP04
Conversion accessory to mount the device directly on panel door
GV7AP05
Black rotary operating handle with black legend plate and extension kit (185–600 mm)
GV7AP01
Red rotary operating handle with yellow legend plate and extension kit (185–600 mm)
GV7AP02
Padlocking device for toggle handle (max. 38 mm padlocks)
GV7V01
Table 18.139: Operating Handles
Accessory Description Catalog Number
Operating Handle (Qty: 1)
NEMA 1/12 Black handle with trip indication
GVAPB54
NEMA 1/12 Red/Yellow handle with trip
indication
GVAPR54
NEMA 3R/4/4X Black handle without trip
indication
GVAPB65
NEMA 3R/4/4X Red/Yellow handle without
trip indication
GVAPR65
Dimensions: page 18-77 and page 18-79
GVAPB54 GVAPR54
Motor Protector Circuit Breakers
Listed to UL 60947-4-1, these manual starters provide built-in thermal and magnetic
protection.
Table 18.140: PowerPact™ Electronic Motor Protector Circuit Breakers (Manual Starters)
Electronic
Trip Unit
Type
Frame
Sensor
Rating
Trip
Unit
Full Load Ampere
Rating (FLA)
Isd
(x FLA)
G Interrupting J Interrupting L Interrupting R Interrupting
Cat. No. Cat. No. Cat. No. Cat. No.
Standard [44]
H-Frame
30
2.2 M
14-25 5-13 x FLA HGL36030M38X HJL36030M38X HLL36030M38X HRL36030M38X
50 14-42 5-13 x FLA HGL36050M38X HJL36050M38X HLL36050M38X HRL36050M38X
100 30-80 5-13 x FLA HGL36100M38X HJL36100M38X HLL36100M38X HRL36100M38X
150 58-130 5-13 x FLA HGL36150M38X HJL36150M38X HLL36150M38X HRL36150M38X
J-Frame 250 114-217 5-13 x FLA JGL36250M38X JJL36250M38X JLL36250M38X JRL36250M38X
L-Frame
400
2.3 M
190-348 5-13 x FLA LGL36400M38X LJL36400M38X LLL36400M38X LRL36400M38X
600 312-520 5-13 x FLA LGL36600M38X LJL36600M38X LLL36600M38X LRL36600M38X
E164862
CCN NLDX
LR43364
Class 3211 04
NOTE: For additional information and accessories, refer to Section 7: Miniature and
Molded Case Circuit Breakers.
18
CONTACTORS AND STARTERS-IEC
[43] Wire size: GV7AC021 = 14 to 3/0 AWG; GV7AC022 = 14 AWG to 350 kcmil.
[44] The standard trip unit offers Class 5, 10, and 20 and phase unbalance or phase loss protection.