Brochure

18-36
© 2019 Schneider Electric
All Rights Reserved
Motor Starters and Protectors TeSys™ GV Manual Starters and Protectors
www.se.com/us
Refer to Catalog 2520CT0001
GVAE11
Table 18.134: Auxiliary Contact Blocks [37]
Description
Mounting
Location
Max. No. of
Blocks
Contact Type
Sold in
lots of
Cat. No.
Instantaneous auxiliary
contacts GV2 or GV3P
Front [38][39]
1
N.O. or N.C. [40]
1 GVAE1
N.O. + N.C. 10
GVAE11 [41]
N.O. + N.O. 1
GVAE20 [41]
Left Hand Side 2
N.O. + N.C. 1
GVAN11 [41]
N.O. + N.O. 1
GVAN20 [41]
Fault signaling contact +
instantaneous auxiliary
contact GV2 or GV3P
Left Hand Side
[42]
1
N.O. (fault) + N.
O.
1 GVAD1010
N.O. (fault) + N.C.
1 GVAD1001
N.C. (fault) + N.O.
1 GVAD0110
N.C. (fault) + N.C.
1 GVAD0101
Short circuit signaling
contact GV2 or GV3P
Left Hand Side 1 SPDT 1 GVAM11
GVAD0101 GVAN11
Table 18.135: GV3P Accessories
Accessory Application / Use With
Standard
Pack
Cat. No.
Through-the-door
operating mechanism
kits
NEMA 1, 12, Black with trip indication, for use with GV3P
1 GV3APN01
NEMA 1, 12, Red/Yellow, with trip indication, for use with
GV3P
1 GV3APN02
NEMA 3R, 4, 4X Red/Yellow without trip indication, for use
with GV3P
1 GV3APN04
Angle bracket
Operating mechanism support shaft for deep enclosures (≥
300 mm), for use with GV3P
1 GVAPK12
Mounting bracket Mounting bracket for installing GV3P operating mechanism
1 GVAPH03
3-pole, 115 A busbar
For feeding 2 GV3P starters, 64 mm pitch
1 GV3G264
For feeding 3 GV3P starters, 64 mm pitch
1 GV3G364
Incoming line spacer
Line spacer for GV3P when used in UL 508 Type E
applications. One spacer required on line side.
1 GV3G66
IP 20 cover
IP20 protective cover for ring tongue versions of GV3P and 3-
pole TeSys D Everlink contactors. Two covers required for line
and load side.
1 LAD96570
Padlocking device
For use with up to 4 padlocks (not supplied). Ø 6 mm shank
maximum
1 GV2V03
Operating mechanism
short shaft
One-piece short shaft for installing operating mechanisms in
shallow enclosures, for use with GV2P, GV3P and TeSys U
1 GVAPA2
SoLink non-reversing
communications link
Connection module for directly mounted GV3 and TeSys D
contactor to PLC
5 LAD5C31
SoLink reversing
communications link
Connection module for directly mounted GV3 and reversing
TeSys D contactor to PLC
3 LAD5C32
Laser tool
Laser tool for installing through-the-door kits
1 GVAPL01
S-shaped busbar
For connecting GV3P starters and LC1D40A-65A contactors
side by side without intrawiring
1 GV3S
TeSys™ GV2, GV3, GV7 Manual Starters and Protectors
GV7AE11
Table 18.136: GV7 Auxiliary Contact Blocks (auxiliary contact functions depends
on location inside the device)
Description Mounting Location
Max. No. of Blocks
Contact Type Catalog Number
Standard
Instantaneous
Inside Device
2 per device
N.O. + N.C.
GV7AE11
Trip Indication 1 per device
N.O. + N.C.
Fault Indication
1 per device
N.O. + N.C.
Low Level
Instantaneous
Inside Device
2 per device
N.O. + N.C.
GV7AB11
Trip Indication 1 per device
N.O. + N.C.
Fault Indication
1 per device
N.O. + N.C.
GV7AD111 GV7AS055
Table 18.137: GV7 Voltage Trips
Description Mounting Location
Max. No. of Blocks
Voltage
Catalog
Number
Undervoltage Trip
Inside Device
1 per device
48 Vac 50 Hz GV7AU055
110–130 Vac 50/60 Hz GV7AU107
200–240 Vac 50/60 Hz GV7AU207
380–440/480 Vac 50/60 Hz GV7AU387
525 Vac 50 Hz GV7AU525
Shunt Trip
Inside Device
1 per device
48 Vac 50 Hz GV7AS055
110–130 Vac 50/60 Hz GV7AS107
200–240 Vac 50/60 Hz GV7AS207
380–440/480 Vac 50/60 Hz GV7AS387
525 Vac 50 Hz GV7AS525
Fault Indication Inside Device
1 per device
24–130 GV7AD111
110–415 GV7AD112
18
CONTACTORS AND STARTERS-IEC
[37] One trip or one fault signaling can be fitted per GV3.
[38] Cannot be used with GV2GH7 insulator.
[39] Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.
[40] Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.
[41] For spring terminals, add 3 to the catalog number (for example, GVAE113).
[42] The GVAD is always mounted next to the starter.
9/13/2019