TeSys™ GV Manual Starters and Protectors Motor Starters and Protectors
Refer to Catalog 2520CT0001
GV2P + LC1D Pre-Assembled Kits
GV2P02KD09••
Simplify your life! These new pre-assembled kits come with a GV2P manual motor
protector already connected to an LC1D contactor. Panel builders and end users can
now save wiring time by purchasing the pre-assembled kits.
Table 18.131: Pre-Assembled Kits
Description
Overload Relay
Trip Range
Coil Voltage
LC1D Contactor
Catalog No.
Kit Catalog No.
Pre-Assembled Kits
0.16–0.25 A
24 Vac LC1D09B7 GV2P02KD09B7
120 Vac LC1D09G7 GV2P02KD09G7
24 Vdc LC1D09BL GV2P02KD09BL
0.25–0.40 A
24 Vac LC1D09B7 GV2P03KD09B7
120 Vac LC1D09G7 GV2P03KD09G7
24 Vdc LC1D09BL GV2P03KD09BL
0.40–0.63 A
24 Vac LC1D09B7 GV2P04KD09B7
120 Vac LC1D09G7 GV2P04KD09G7
24 Vdc LC1D09BL GV2P04KD09BL
0.63–1 A
24 Vac LC1D09B7 GV2P05KD09B7
120 Vac LC1D09G7 GV2P05KD09G7
24 Vdc LC1D09BL GV2P05KD09BL
1–1.6 A
24 Vac LC1D09B7 GV2P06KD09B7
120 Vac LC1D09G7 GV2P06KD09G7
24 Vdc LC1D09BL GV2P06KD09BL
1.6–2.5 A
24 Vac LC1D09B7 GV2P07KD09B7
120 Vac LC1D09G7 GV2P07KD09G7
24 Vdc LC1D09BL GV2P07KD09BL
2.5–4 A
24 Vac LC1D09B7 GV2P08KD09B7
120 Vac LC1D09G7 GV2P08KD09G7
24 Vdc LC1D09BL GV2P08KD09BL
4–6.3 A
24 Vac LC1D09B7 GV2P10KD09B7
120 Vac LC1D09G7 GV2P10KD09G7
24 Vdc LC1D09BL GV2P10KD09BL
6–10 A
24 Vac LC1D09B7 GV2P14KD09B7
120 Vac LC1D09G7 GV2P14KD09G7
24 Vdc LC1D09BL GV2P14KD09BL
9–14 A
24 Vac LC1D25B7 GV2P16KD25B7
120 Vac LC1D25G7 GV2P16KD25G7
24 Vdc LC1D25BL GV2P16KD25BL
13–18 A
24 Vac LC1D25B7 GV2P20KD25B7
120 Vac LC1D25G7 GV2P20KD25G7
24 Vdc LC1D25BL GV2P20KD25BL
17–23 A
24 Vac LC1D25B7 GV2P21KD25B7
120 Vac LC1D25G7 GV2P21KD25G7
24 Vdc LC1D25BL GV2P21KD25BL
20–25 A
24 Vac LC1D25B7 GV2P22KD25B7
120 Vac LC1D25G7 GV2P22KD25G7
24 Vdc LC1D25BL GV2P22KD25BL
Voltage Trips
GVAU116
Table 18.132: Voltage Trips
Only one trip or fault signaling contact can be installed per GV2/GV3 device.
Description
Characteristics
Voltage Frequency Cat. No. [35]
Voltage trips GV2 or
GV3P
Undervoltage or
Shunt trip
(external
mounting, 1 block
right side only)
24 V
50 Hz GVA●025
60 Hz GVA●026
48 V
50 Hz GVA●055
60 Hz GVA●056
100–110 V 50/60 Hz GVA●107
110–115 V
50 Hz GVA●115
60 Hz GVA●116
120–127 V 50 Hz GVA●125
127 V 60 Hz GVA●115
200 V 50 Hz GVA●207
200–220 V 60 Hz GVA●207
220–240 V
50 Hz GVA●225
60 Hz GVA●226
380–400 V
50 Hz GVA●385
60 Hz GVA●386
415–440 V 50 Hz GVA●415
415 V 60 Hz GVA●416
440 V 60 Hz GVA●385
480 V 60 Hz GVA●415
500 V 50 Hz
GVA●505
600 V 60 Hz
Table 18.133: Voltage Trips–Technical Data (GV2AU, GV2AS)
Rated Voltage—660 Vac
Model Inrush Sealed
Pick-Up Voltage Drop-Out Voltage Operating Time [36]
GVAU 12 VA / 8 W 3.5 VA / 1.1 W 0.8—1.1 0.35—0.7 10—15 ms
GVAS 14 VA / 10.5 W 5 VA / 1.6 W 0.7—1.1 0.2—0.75 10—15 ms
18
CONTACTORS AND STARTERS-IEC
[35] To order an undervoltage trip: replace the bullet (●) with a U (for example, GVAU025).
To order a shunt trip: replace the bullet ( ●) with an S (for example, GVAS025).
[36] From the loss of voltage at the trip terminals to the opening of the starter contacts.