Brochure
© 2019 Schneider Electric
All Rights Reserved
18-33
www.se.com/us
TeSys™ GV Accessories and Enclosures Motor Starters and Protectors
Refer to Catalog MKTED210011EN
TeSys™ GV2 Accessories and Enclosures
GV2GH7
LAD311LAD31
Table 18.125: GV2 Mounting Accessories
Description Application
Standard
Pack [32]
Catalog
Number
Common mounting plate
For GV2 plus any 3-pole LC1D09 thru LC1D25
contactor (supplied with GV1G02 connector)
1 GK2AF01
Adapter plate For screw mounting of GV2M
10 GV2AF02
Combination block
Interconnect for GV2 plus any 3-pole LC1K or LP1K
contactor
10 GV2AF01
Interconnect GV2 and LC1D09 thru D32 10 GV2AF3
Interconnect GV2 and LC1D09 thru D32 mounted on
LAD31
10 GV2AF4
7.5 mm compensation
plate
To allow mounting of GV2M and GV2P on a common
bus bar
10 GV1F03
Mounting plate
For mounting GV2ME or GV2P and contactor LC1D09
thru D32
10 LAD31
10 LAD311
GV2AF3/G2AF4
Table 18.126: GV2 Cabling Accessories—Bus Bars
Description Application
Pitch
Standard Pack
[32]
Catalog
Number
3-Pole, 63 A Bus Bar
For feeding 2 GV2 starters
45 1 GV2G245
54 1 GV2G254
72 1 GV2G272
For feeding 3 GV2 starters
45 1 GV2G345
54 1 GV2G354
For feeding 4 GV2 starters
45 1 GV2G445
54 1 GV2G454
72 1 GV2G472
For feeding 5 GV2 starters
54 1 GV2G554
Table 18.127: GV2 Other Cabling Accessories
Description Application
Standard
Pack [32]
Catalog
Number
Terminal blocks
Top feed for use with bus bars
1 GV1G09
Bottom feed, to be used with bus bars; can be fitted with
GV1L3 current limiter
1 GV2G05
Protective end cover To cover unused bus bar outlets 5 GV1G10
3-pole flexible connector For connecting a GV2 to an LC1D09 thru D25 contactor
10 GV1G02
Incoming line spacer For GV2P when used in UL 508 Type E applications [33]
1 GV2GH7
Table 18.128: GV2 Other Accessories
Description Application
Standard
Pack [32]
Catalog
Number
Visible isolation block—
GV2P
Front mounting, 3-pole visible isolation on incoming side
of GV2P
1 GV2AK00
Current limiter—GV2
Increases interrupt capacity when attached to GV2ME or
GV2P
1 GV1L3
Through-the-door
operating mechanism kits
NEMA 1, 12, Black with trip indication, for use with GV2P
1 GV2APN01
NEMA 1, 12, Red/Yellow with trip indication, for use with
GV2P
1 GV2APN02
NEMA 3R, 4, 4X, Red/Yellow without trip indication,
for use with GV2P
1 GV2APN04
Angle bracket
Operating mechanism support shaft for deep enclosures
(≥ 250 mm), for use with GV2P
1 GVAPK11
Mounting bracket
Mounting bracket for installing GV2P operating
mechanism
1 GVAPH02
Operating mechanism
short shaft
One-piece short shaft for installing operating
mechanisms in shallow enclosures, for use with GV2P,
GV3P and TeSys U
1 GVAPA2
SoLink non-reversing
communications link
Connection module for directly mounted GV2 and TeSys
D contactor to PLC
5 LAD5C11
SoLink reversing
communications link
Connection module for directly mounted GV2 and
reversing TeSys D contactor to PLC
3 LAD5C12
Laser tool
Laser tool for installing through-the-door kits
1 GVAPL01
Table 18.129: GV2 Enclosures
Description Listing Mounting Enclosure Rating
Max. Side Mounting Aux. Contacts
Catalog Number
Left Side
Right Side
Enclosures for GV2ME
with or without
accessories
CSA Listed. Not UL
Listed.
Surface mounting
NEMA 1, IP41
1 1 GV2MC01
NEMA 12/4, IP55
1 1 GV2MC02
Flush mounting
NEMA 1, IP41
1 1 GV2MP01
NEMA 12/4, IP55
1 1 GV2MP02
Flush mounting, front
face reduced
NEMA 1, IP41
0 1 GV2MP03
NEMA 12/4, IP55
0 1 GV2MP04
Table 18.130: GV2 Enclosures Accessories
Description Type Standard Pack [32] Catalog Number
Padlocking device for GV2M (when
padlocked, starter is automatically in Off
position)
— 1 GV2V01
Mushroom head stop push button
(40 mm, red) [34]
Spring return
1 GV2K011
Latching
Key release (Ronis key no. 455)
1 GV2K021
Turn to Release 1 GV2K031
18
CONTACTORS AND STARTERS-IEC
[32] Orders must specify multiples of quantities listed.
[33] Cannot be used with front-mounted auxiliary contact block.
[34] Supplied with IP55 sealing kit.
9/13/2019