Brochure

© 2019 Schneider Electric
All Rights Reserved
18-31
www.se.com/us
TeSys™ H Ultra Compact Starters Motor Starters and Protectors
Refer to Catalog MKTED210011EN
Table 18.117: Soft Starter Forms [27]
Factory Modifications
Form
Motor FLA < 6A H1
6 < Motor FLA < 9A H2
9 < Motor FLA < 12A H3
12 < Motor FLA < 22A H4
22 < Motor FLA < 32A H5
Table 18.118: Distributed 6 Input/6 Output Modicon STB with Communication
Forms
[28]
Factory Modifications
Form
DeviceNet Bus W10
Modbus TCP Bus W11
Ethernet IP Bus W12
CANOpen Bus
W13
Profibus Bus W14
Table 18.119: Starter Status Indication Forms
Factory Modifications
Form
Fault Differentiation Module—Manual Reset U1
Fault Differentiation Module—Automatic or remote reset U2
Thermal Overload Alarm Module U3
Motor Load Indication Module U4
TeSys H™ Ultra Compact Starters
TeSys H ultra compact motor starters are extremely compact motor starters for
asynchronous motors (AC53a utilization category) and resistive loads (AC51 utilization
category). With up to 75% space savings, the 22.5 mm wide starter maintains that width
even for a reversing starter! An available safety version features embedded Safe Torque
Off and is SIL3 according to IEC 61508-1 and Ple according to ISO 13849-1. TeSys H is
ideal for industries such as food and beverage, logistics, and durable goods.
TeSys H™ Ultra Compact Starter
TeSys H Ultra Compact Safety Starter
Table 18.120: TeSys H Ultra Compact Motor Starters
Non-Reversing
Maximum HP Ratings Current Setting Range (A)
Catalog
Number [29][30]
200 V 230 V 460 V
Inductive
AC53a
Resistive AC51
0.5 0.5 1 0.18 –2.4 0.18–2.4 LZ1H2X4
1 1.5 3 1.5–6.5 1.5–9.0 LZ1H6X5
Reversing
Maximum HP Ratings Current Setting Range (A)
Catalog
Number [29][30]
200 V 230 V 460 V
Inductive
AC53a
Resistive AC51
0.5 0.5 1 0.18 –2.4 LZ2H2X4
1 1.5 3 1.5–6.5 LZ2H6X5
Table 18.121: TeSys H Ultra Compact Safety Motor Starters (SIL3)
Non-Reversing
Maximum HP Ratings Current Setting Range (A)
Catalog
Number [29][30]
200 V 230 V 460 V
Inductive
AC53a
Resistive AC51
0.5 0.5 1 0.18 –2.4 0.18–2.4 LZ7H2X4
1 1.5 3 1.5–6.5 1.5–9.0 LZ7H6X5
Reversing
Maximum HP Ratings Current Setting Range (A)
Catalog
Number [29][30]
200 V 230 V 460 V
Inductive
AC53a
Resistive AC51
0.5 0.5 1 0.18 –2.4 LZ8H2X4
1 1.5 3 1.5–6.5 LZ8H6X5
Table 18.122: TeSys H Voltage Codes
24 Vdc 110–230 Vac (50/60Hz)
BD FU
18
CONTACTORS AND STARTERS-IEC
[27] Motor Voltage must be equal to or less than 480 Vac and Control Voltage must be 24 Vdc (Control Power Source Codes BD, BD1, or BD2 only). Refer to Table 18.103.
[28] Distributed I/O Modicon STB is factory wired.
[29] Complete the catalog number by adding the voltage code from . For example, LZ1H2X4 becomes LZ1H2X4BD.
[30] For spring terminals, add 3 to the catalog number prior to adding the voltage code. For example, LZ1H2X4BD becomes LZ1H2X43BD.