Brochure
18-30
© 2019 Schneider Electric
All Rights Reserved
Motor Starters and Protectors TeSys™ U Enclosed Combination Starters
www.se.com/us
Refer to Catalog MKTED210011EN
Self-Protected Combination Starters
Table 18.108: 22 mm Standard LED Pilot Light Forms
Factory Modifications
Form
Red ON P51
Green OFF P52
White—Not Factory wired
P54
Blue—Not Factory wired
P56
Amber Overload Trip
P68
Yellow SSC Trip
P69
Red OFF P91
Green ON P92
Green Forward/Reverse P95
Red Forward/Reverse P96
Table 18.109: 22 mm Push-to-Test LED Pilot Light Forms
Factory Modifications
Form
Red ON P42
Red OFF P43
Green ON P45
Green OFF P46
Blue—Not Factory wired
P66
White—Not Factory wired
P67
Green Forward/Reverse P79
Red Forward/Reverse P80
Amber Overload Trip
P88
Yellow SSC Trip
P89
Table 18.110: Separate Control Forms
Factory Modifications
Form
Separate Control for starters with line voltage less or equal to 480 V
S
Separate Control for starters with line voltage equal to 600 V—Current Limiter is
factory installed.
S6
Table 18.111: Additional Capacity Forms
Factory Modifications
Form
50 VA additional capacity
T10
100 VA additional capacity
T11
NOTE: Fuses are provided. Two fuses in primary and one fuse in secondary.
Table 18.112: Auxiliary Contact Forms
Factory Modifications
Form
2 N.O. U8
1 N.O. and 1 N.C. U9
2 N.C. U10
1 N.C. fault signaling contact and 1 N.O. contact indicating starter is in "ready" state
U6
1 N.O. fault signaling contact and 1 N.O. contact indicating starter is in "ready" state
U7
Table 18.113: Auxiliary Relay Forms
Factory Modifications
Form
4 poles screw clamp Control Relay—4 N.O.
R1740
4 poles screw clamp Control Relay—3 N.O. and 1 N.C.
R1731
4 poles screw clamp Control Relay—2 N.O. and 2 N.C.
R1722
Programmable Timer Relay
K1070
Table 18.114: Enclosure Forms
Factory Modifications
Form
Oversized enclosure—Only available for Type 1/12/3R
G28
Plain Blank Door—No covered pre-stamped holes
G30
Table 18.115: Miscellaneous Forms
Factory Modifications
Form
Nameplate—2”x1/2” screwed
A241
Nameplate—3”x1” screwed
A242
Unwired Terminal Block
G50 [25]
Wired Terminal Block
G56 [25][26]
Wire Markers G105
Padlock Attachment G122
Transient Suppressor
U11
Black IP65 through the Door Rotary Disconnect Handle
G40
Special Factory Orders
SPL
Customer Control Wiring
Y217
Solid Neutral Terminal Block N
Table 18.116: Increase Short Circuit Current Rating Forms
Factory Modifications
Form
130 kA @480 V—Current Limiter factory installed
Y1261
18
CONTACTORS AND STARTERS-IEC
[25] Add number of terminal block points required. Number must be in increments of 5.
[26] Wiring diagram must be provided by customer.
9/13/2019