Motor Starters and Protectors TeSys™ U Enclosed Combination Starters
www.se.com/us
Refer to Catalog MKTED210011EN
3. Choose the Control Power Source
Table 18.103: Control Power Source Code
Control Circuit Source
System Type
Motor Voltage Control Voltage
Control Power Source
Code
Voltage Voltage Type Voltage Voltage Type
Common Control
Single Phase
120 AC 120 AC G7
240 AC 240 AC U7
Three-Phase
208 AC 208 AC LE7
240 AC 240 AC U7
Separate Control
Single Phase
120 AC 24 AC
B7 [21]
120 AC 24 DC
BD [21]
120 AC 120 AC
G7 [21]
240 AC 24 AC
B7 [21]
240 AC 24 DC
BD [21]
240 AC 120 AC
G7 [21]
Three-Phase
208 AC 24 AC
B7 [21]
208 AC 24 DC
BD [21]
208 AC 120 AC
G7 [21]
240 AC 24 AC
B7 [21]
240 AC 24 DC
BD [21]
240 AC 120 AC
G7 [21]
480 AC 24 AC
B7 [21]
480 AC 24 DC
BD [21]
480 AC 120 AC
G7 [21]
600 AC 24 AC
B7 [22]
600 AC 24 DC
BD [22]
600 AC 120 AC
G7 [22]
Factory Installed Control
Power Transformer [23]
Single Phase
120 AC 24 AC V89
240 AC 120 AC V80
240 AC 24 AC V82
Three-Phase
208 AC 24 AC V90
208 AC 120 AC V84
240 AC 24 AC V82
240 AC 120 AC V80
480 AC 24 AC V83
480 AC 120 AC V81
600 AC 24 AC V91
600 AC 120 AC V86
Factory Installed Power
Supply [24]
Single Phase
120 AC 24 DC BD1
240 AC 24 DC BD2
Three-Phase
208 AC 24 DC BD2
240 AC 24 DC BD2
480 AC 24 DC BD2
600 AC 24 DC BD6
4. Choose Communication Type
If you do not need communication capabilities, select communication code N.
If a Communication protocol is selected, Control Voltage must be 24 Vdc (Control Power
Source Codes BD, BD1, BD2 or BD6 only. Refer to ).
If additional I/O is needed with communication, select communication code N in Table
18.104 and choose between Forms W10, W11, W12, W13 and W14 from .
Table 18.104: Communication Code
Communication Protocol Communication Code
Modbus M
Modbus TCP/IP E
CANopen
C
DeviceNet D
Beckoff B
Profibus P
Advantys STB
A
AS-interface J
AS-interface V2 K
No Communication N
5. Choose Factory Modifications
When choosing Factory modifications, the Form code must be added at the end of the
catalog number. If several forms are selected, they must be arranged in alphabetical
order. There are two types of Forms available: abbreviated forms and standard forms.
18
CONTACTORS AND STARTERS-IEC
[21] Form S must be added at the end of the catalog number.
[22] Form S6 must be added at the end of the catalog number. Current limiter is provided and factory installed.
[23] Two fuses in primary and one fuse in secondary provided as standard.
[24] Fuse holder with 2 fuses provided as standard.