TeSys™ D and F Overload Relays Overload Relay Accessories
Refer to Catalog MKTED210011EN
TeSys D Overload Relay Accessories
LA7D901
Table 18.75: Mounting Kits and Plates[1]
Description For use with overload relays:
Cat. No.
Separate mounting kits for mounting to
35 mm DIN rail or for panel mounting
with screws
LRD01–35 and LR3D01–35 LAD7B10
LRD01–35 and LRD01–35 for ring tongue terminals
LAD7B106
LRD04L–-32L, LR3D04L–32L, and LR9D01–32
LAD7B205
LRD3●●●, LR3D3●●●, LR2D35●●
LA7D3064
Mounting plates for screw mounting at
110 mm (4.3 in.) centers
LRD01–35, LR3D01–35, LR2D15●●
DX1AP25
LRD3●●●, LR3D3●●, LR2D35●●
LA7D902
LA7D03
Table 18.76: Accessories
Description
For use with
Standard
Package
Catalog
Number
Prewiring kit allows direct connection of
the N.C. contact of relay LRD01–D32 or
LR3D01–D32 to the contactor
LC1D09 to D18 10 LAD7C1
LC1D25 to D38 10 LAD7C2
Stop button locking device
All relays except LRD01–D32, LR3D01–D32
and LR9D
10 LA7D901
Remote stop/tripping or electrical reset
[2]
LRD01-D32, LRD3, LR3D01-D32, LR3D3
 1
LAD703 [3]
All relays except LRD01–D32, LR3D01–D31
 1
LA7D03 [3]
Reset by flexible cable 500 mm (19.6 in.)
LRD01-D32, LRD3, LR3D3
 1 LAD7305
Table 18.77: Control Circuit Voltages for LA7D03 and LAD703
Volts 12 24 48 110 220/230 380/400 415/440
AC 50/60 Hz
J [4]
B E F M
Q
N
DC J B E F M
TeSys F Overload Relay Accessories
LA7F90●
Table 18.78: Mounting Plate for Overload Relay
For use with relays Catalog Number
LR9F5●57, F5●63, F5●67, F5●69, F5●71, F57, F63, F67, F69, and F71
LA7F901
LR9F7●75, F7●79, F5●81, F75, F79, and F81
LA7F902
These clear plastic protective shrouds are an effective means to meet international
finger-safe requirements for power terminals. They are designed to be used with power
cables that have been bolted to the terminal.
NOTE: Protection shrouds do not attach to contactors/overloads using DZ2F lug kits.
LA9F70●
Table 18.79: Power Terminal Protection Shrouds, Single-Pole
For use with relays Catalog Number
LR9F5●57, F57
LA9F701
LR9F5●63, F5●67, F5●69, F63, F67, F69
LA9F702
LR9F5●71, F71
LA9F705
LR9F7●75, F7●79, F7●81, F75, F79, F81
LA9F703
Table 18.80: Power Terminal Protection Shrouds, 3-Pole
For use with relays Catalog Number
LR9F5●57, F5●63, F5●67, F5●69, F57, F63, F67, F69
LA7F701
LR9F5●71, F71
LA7F702
LR9F7●75, F7●79, F7●81, F75, F79, F81
LA7F703
LA7F701
Table 18.81: Connection Accessories (for Mounting Overload Relays Beneath
Reversing Contactors)
[5]
Application
Set of 3 Busbars
Catalog Number
For relays
For contactor
LR9F5●57, F5●63, F5●67, F5●69, F69, F71
LC1F115 LA7F401
LR9F5●57, F5●63
LC1F150 and F185 LA7F402
LR9F5●71, F71
LC1F185 LA7F407
LR9F5●71, F71
LC1F225 and F265 LA7F403
LR9F7●75, F5●79, F75, F79
LC1F225 to F400 LA7F404
LR9F7●81, F81
LC1F400 LA7F404
LR9F7●75, F7●79, F7●81, F75, F79, F81
LC1F500 LA7F405
LR9F7●81, F81
LC1F630 and F800 LA7F406
Table 18.82: Marking Accessories
Description
Sold in units of:
Catalog Number
Marker holder, snap-in
100 LA7D903
Main overload selection: page 18-6 and page 18-10
TeSys D dimensions: page 18-66 and page 18-68
TeSys F dimensions: page 18-62, page 18-70
TeSys T: see page 16-103
18
CONTACTORS AND STARTERS-IEC
[1] When using mounting plates, separate mounting kits are also required.
[2] The time that the LA7D03 can remain energized depends on its rest time; 1 s pulse with 9 s rest time; 5 s pulse with 30 s rest time; 10 s pulse with 90 s rest time; maximum pulse duration of
20 s with rest time of 300 s. Consumption on inrush and sealed: < 100 VA
[3] Part number to be completed by adding coil voltage code, (for example, LAD703F).
[4] Not available for LRD01–D32, LR3D01–D32.
[5] Mounting plate required.