Brochure
18-20
© 2019 Schneider Electric
All Rights Reserved
Contactor Accessories TeSys™ F Contactors
www.se.com/us
Refer to Catalog MKTED210011EN
TeSys™ F Contactors
LA9D09981, LA9F980
Table 18.70: Suppressor Blocks
Operating limit: up to 220 V, 50/60 Hz coils
Description
For Use with coils
Catalog
Number
Suppressor block
(clip-on mounting to
coil)
LX1FH, F265, F330
LA9F980
LX1FJ, FK, FL, FX, F400, F500, F630, F780, LX9FF, FG, FH, F115,
F150, F185, F225, F265, F330
LA9D09980
Mounting bracket (for 35 mm DIN rail or panel mounting) for suppressor block
LA9D09981
Table 18.71: Lugs and Lug Kits [30]
Contactor
Type LC1
Lug Kit
Catalog Number
Contactor Only
Cable Size
AWG range
Overload Relay
Directly mounted
to contactor
Lugs Required Cable size AWG range
LC1●
Line side of
contactor
Load side of
overload
Line side of
contactor
Load side of
overload
F115 DZ2FF6 14 to 2/0
LR9F5●57–F5●69,
LR9F57–F69
F115 3 each DZ2FF1 3 each DZ2FG1 14 to 2/0 6 to 3/0
F150, F185
DZ2FG6 6 to 3/0
LR9F5●57–F5●71,
LR9F57–F71
F150–F185 1 each DZ2FG6 6 to 3/0
— — —
LR9F5●71, LR9F71 F225, F265
1 each DZ2FH6 6 to 300 MCM
F225, F265,
F330
DZ2FH6 6 to 300 MCM
LR9F7●75–F7●79,
LR9F75–F79
F265 or F330 3 each DZ2FH1 — 6 to 300 MCM 4 to 500 MCM
F400 DZ2FJ6 4 to 500 MCM
LR9F7●75–F7●81,
LR9F75–F81
F400 3 each DZ2FJ1 — 4 to 500 MCM 4 to 500 MCM
F500 DZ2FK6 2 x 2 to 600 MCM
LR9F7●75–F7●81,
LR9F75–F81
F500 3 each DZ2FK1 — 2x2 to 600 MCM 4 to 500 MCM
F630, F800
DZ2FL6 3 x 2 to 600 MCM
LR9F7●81, LR9F81
F630
1 each DZ2FL1
DZ2FL2
DZ2FL3
1 each DZ2FR1 3x2 to 600 MCM 4 to 500 MCM
F780 DZ2FX6
4 x 1/0 to 750
MCM
— — — — — —
Table 18.72: Lugs, 2- and 4-Pole [31]
Contactor Type LC1
Lug Kit
Catalog Number
Qty. Required
AL/CU
Cable Size
2-Pole 4-Pole
F115 DZ2FF1 4 8 14 to 2/0
F150, F185
DZ2FG1 4 8 6 to 3/0
F225, F265, F330
DZ2FH1 4 8 6 to 300 MCM
F400 DZ2FJ1 4 8 4 to 500 MCM
F500 DZ2FK1 4 8 2 X 2 to 600 MCM
F630
DZ2FL● [32] [32] [32]
3 X 2 to 600 MCM
F780 DZ2FX1 4 8 4 X 1/0 to 750 MCM
These clear plastic protective shrouds are an effective means to meet international
touch-safe requirements for power terminals. They are designed to be used with power
cables that have been bolted to the terminal.
NOTE: The protection shrouds do not attach to contactors or overloads using DZ2F
lug kits.
LA9F70●
Table 18.73: Power Terminal Protection Shrouds
For Use With 2-, 3-, And 4-pole Contactors
Number of
Shrouds
Per Set
Catalog Number
LC1F115 6 LA9F701
LC1F150, F185
6 LA9F702
LC1F225, F265, F330, F400 and F4002, F500 and F5002
6 LA9F703
LC1F630, F6302 and F800
6 LA9F704
LC1F1154 8 LA9F706
LC1F1504 and F1854 8 LA9F707
LC1F2254, F2654, F3304, F4004, F5004
8 LA9F708
LC1F6304 8 LA9F709
For contactors LC1F115, LC1F150, and LC1F185, an available touch-safe terminal block
may be used in place of lugs for power connections.
Table 18.74: Insulated Terminal Blocks
For contactor type LC1 For overload relay LR9
Maximum Cable Size
Catalog Number
F115, F150, F185
F5●57, F5●63, F5●67, F5●69,
F57, F63, F67, F69
300 MCM LA9F103
TeSys F contactor accessories: page 18-15
TeSys F overload relay accessories: page 18-21
TeSys F replacement coils and parts: page 18-57, page 18-53, and page 18-56
TeSys F dimensions: page 18-62, page 18-70
18
CONTACTORS AND STARTERS-IEC
[30] Lug kits ending in the number 6 include 6 identical lugs. In some cases the LR9F overload relay mounted directly on the load side of an LC1F contactor will require a different size lug for
your choice of contactor and overload. If the two sizes are different, order 3 of each size lug. Mounting hardware (screws, washers, and nuts) are provided with the contactors and overload
relays, not with the lugs.
[31] Lugs for LC1F contactors and overload relays must be ordered separately. Each kit consists of one lug. Mounting hardware (screws, washers, nuts) are provided with the contactors, not the
lugs.
[32] For 2-pole F630 contactors, order two DZ2FL1 (L1 and T2), and two DZ2FL3 (L2 and T1).
For 4-pole F6304, order two DZ2FL1 (L1 and T4), four DZ2FL2 (L2, T2, L3, T3) and two DZ2FL3 (L4 and T1).
9/13/2019