Brochure

18-2
© 2019 Schneider Electric
All Rights Reserved
Contactors and Overload Relays TeSys™ K Contactors and Overload Relays
www.se.com/us
Refer to Catalog MKTED210011EN
TeSys™ K Non-Reversing Mini-Contactors
LC1K09 LP4K09
Table 18.1: AC Operating Coils
Maximum Horsepower Ratings Maximum Current (A) Continuous
Current
Rating (A)
Type of
Connection
Auxiliary
Contacts
Catalog
Number
[1][2][3][4]
Single-Phase Three-Phase
Inductive AC3 Resistive AC1
115 V 230 V 200 V 230 V 460 V 575 V N.O. N.C.
0.5 1 1.5 1.5 3 3 6 20 10
Screw-clamp
1 LC1K0610
1 LC1K0601
0.5 1.5 2 3 5 5 9 20 20
Screw-clamp
1 LC1K0910
1 LC1K0901
1 2 3 3 7.5 10 12 20 20
Screw-clamp
1 LC1K1210
1 LC1K1201
Table 18.2: TeSys K Contactors with Spring Terminal Clamps [5]
Maximum Horsepower Ratings Maximum Current (A)
Continuous
Current
Ratings (A)
Catalog
Number [1]
Single-Phase
Three-Phase
Inductive AC3 Resistive AC1
115 V 230 V 200 V 230 V 460 V 575 V
0.33 1 1.5 1.5 3 3 6 20 10 LC●K06●●3
0.33 1.5 2 2 5 5 9 20 10 LC●K09●●3
0.33 1.5 2 2 5 5 12 20 10 LC●K12●●3
Table 18.3: Coil Voltage Codes for AC Contactors
Up to and including 240 V coil with integral suppression device available. Add 2 to the code required (for example, J72).
Vac 50/60 Hz 12 24 42 48 110 120 127 200/208 220/230 230 230/240 277 380/400 400/415 440 480 600
Code J7 B7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 UE7
Q7
N7 R7 T7 X7
Table 18.4: DC Operating Coils
Maximum Horsepower Ratings Maximum Current (A)
Continuous
Current Rating
(A)
Type of
Connection
Auxiliary
Contacts Catalog Number [2][3][4][6]
Single-Phase
Three-Phase
Inductive
AC3
Resistive
AC1
115 V 230 V 200 V 230 V 460 V 575 V N.O. N.C.
0.5 1 1.5 1.5 3 3 6 20 10
Screw-clamp
1 LP1K0610
1 LP1K0601
0.5 1.5 2 3 5 5 9 20 20
Screw-clamp
1 LP1K0910
1 LP1K0901
1 2 3 3 7.5 10 12 20 20
Screw-clamp
1 LP1K1210
1 LP1K1201
Table 18.5: Coil Voltage Codes for DC Contactors
Coil with integral suppression device available. Add 3 to the code required (for example, JD3).
[7]
Vdc 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250
Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD
Table 18.6: DC–Low Consumption Operating Coils (devices have built-in transient suppression)
Maximum Horsepower Ratings Maximum Current (A)
Continuous Current
Rating (A)
Type of
Connection
Auxiliary
Contacts
Catalog Number
[8][2][9][10]
Single-Phase
Three-Phase
Inductive AC3 Resistive AC1
115 V 230 V 200 V 230 V 460 V 575 V N.O. N.C.
0.5 1 1.5 1.5 3 3 6 20 10
Screw-clamp
1 LP4K0610
1 LP4K0601
0.5 1.5 2 3 5 5 9 20 20
Screw-clamp
1 LP4K0910
1 LP4K0901
1 2 3 3 7.5 10 12 20 20
Screw-clamp
1 LP4K1210
1 LP4K1201
Table 18.7: Coil Voltage Codes for DC Contactors—Low Consumption [11]
Vdc 12 24 48 72
Code JW3 BW3 EW3 SW3
18
CONTACTORS AND STARTERS-IEC
[1] Complete the catalog number with the coil voltage code from (for example, LC1K0610G7).
[2] For spring terminal clamps, add a 3 before the coil voltage code (for example, LC2K06103G7). Spring terminal clamps reduce some of the HP and continuous current ratings of the TeSys K
contactors. For ratings, please refer to .
[3] For solder pin terminals, add a 5 before the coil voltage code (for example, LC1K09105B7).
[4] For slip-on terminals, add a 7 before the coil voltage code (for example, LC1K12107M7).
[5] Applies to all TeSys K contactors (LC1K, LC2K, LC7K, LC8K, LP1K, LC2K, LP4K and LP5K).
[6] Complete the catalog number with the coil voltage code from (for example, LP1K09004BD).
[7] 3 W inrush.
[8] Complete the catalog number with the coil voltage code from (for example, LC2K0610BD).
[9] For solder pin terminals, add a 5 before the coil voltage code (for example, LP1K09105BW3).
[10] For slip-on terminals, add a 7 before the coil voltage code (for example, LP1K12107BW3).
[11] 1.8 W inrush.
9/13/2019