TeSys™ D Contactors Contactor Accessories
Refer to Catalog MKTED210011EN
Bidirectional Diode Coil Suppressor
•
Protection provided by limiting the transient voltage to 2 Uc max.
•
Maximum reduction of transient voltage peaks
LAD4T3B
Table 18.60: Bidirectional Peak Limiting Diode
Installed by Mounting on
Operating Voltage
Catalog
Number
Vac (50/60 Hz)
Vdc
Snapping into the cavity on the
right side of the contactor [18]
LC●D09–D38 (3P)
[19]
LC1DT20–DT40 (4P)
24 — LAD4TB
— 24 LAD4TBDL
72 — LAD4TS
— 72 LAD4TSDL
— 125 LAD4TGDL
— 250 LAD4TUDL
— 600 LAD4TXDL
Clip-on front mounting and
connection without tools
to the contactor coil terminals [19]
LC●D40A–D65A
(3P), LC1DT60A–
DT80A (4P)
12–24 12–24 LAD4T3B
25–72 25–72 LAD4T3S
73–125 73–125 LAD4T3G
126–250 126–250 LAD4T3U
251–440 251–440 LAD4T3R
Screw mounting [20]
LC●D80–D95 (3P),
LC1D80 (4P)
12–24 12–24 LA4DB2B
25–72 25–72 LA4DB2S
— 24 LA4DB3B
— 72 LA4DB3S
LAD4BB●●
Table 18.61: Cabling Accessories
Usage Mounting on
Operating Voltage 50/60
Hz
Catalog Number
For adapting existing wiring to a new product
or for use with top-mounting accessory.
LC1D09–D38
Without coil suppression
LAD4BB
With coil
suppression
(varistor)
24–48 Vac LAD4BBVE
50–127 Vac LAD4BBVG
110–250
Vac
LAD4BBVU
For adapting existing wiring to a new product
or for use with top-mounting accessory
LC1D40A–D65A
Without coil suppression
LAD4BB3
TeSys D contactors: page 18-7 and page 18-9
TeSys D contactor accessories: page 18-14
TeSys D overload relay accessories: page 18-21
TeSys D replacement coils: page 18-52
TeSys D dimensions: page 18-60 to page 18-68
TeSys™ D Electronic Timers and Interface Modules
The following accessories require use of cabling accessories (LAD4BB●●) for proper
mounting. See page 18-17 for illustration.
Table 18.62: Electronic Serial Timer Modules
Type
Operational Voltage [21]
Time Delay Catalog Number
24–250 Vac 100–250 Vac
On-delay
LC1D09–D65A LC1D80–D150
0.1–2 s LA4DT0U
1.5–30 s LA4DT2U
25–500 s LA4DT4U
LA4DFE
Table 18.63: Interface Modules
Interface Type [22]
Operational Voltage
Input Voltage Catalog Number
24–250 Vac 100–250 Vac
Relay
LC1D09–D150 — 24 Vdc LA4DFB
LC1D09–D150 — 48 Vdc LA4DFE
Relay Plus
Manual Operation
LC1D09–D150 — 24 Vdc LA4DLB
LC1D09–D150 — 48 Vdc LA4DLE
Solid State LC1D09–D65A LC1D80–D115 24 Vdc LA4DWB
Table 18.64: Automatic-Manual-Stop Control Modules
Operational Voltage
Catalog Number
24–100 Vac 100–250 Vac
LC1D09–D150 — LA4DMK
LAD9ET1S
LADN22S LU9ET1S
Table 18.65: TeSys Safety-Chain Identification System
Description Compatibility
Package
Qty
Catalog Number
Red retrofit contactor safety
cover
LC1D09–D65A,
CAD32, CAD50
10 LAD9ET1S
LC1D80 1 LAD9ET3S
LC1D115–D150 1 LAD9ET4S
Red auxiliary contact block,
2 N.O. + 2 N.C.
LC1D09–D150,
CAD32, CAD50
1 LADN22S
Red retrofit safety sticker TeSys U
10 LU9ET1S
18
CONTACTORS AND STARTERS-IEC
[18] Installing the suppressor into the cavity makes the electrical connection. Overall width of the contactor remains the same.
[19] For LC●D09–LC●D65A with DC or low consumption DC coils, 3-pole contactors are fitted with built-in bidirectional diode suppression as standard.
[20] Mounting at the top of the contactor on coil terminals A1 and A2.
[21] For 24 V operation, the contactor must be fitted with a 21 V coil: coil voltage code Z5 for 50 Hz; Z6 for 60 Hz; and ZD for DC.
[22] Adapter required for D09–D65A, see .