Table of Contents Section 18 Contactors and Starters-IEC TeSys F Contactors Contactor Accessories TeSys™ K Contactors TeSys™ D and F Contactors TeSys™ D Contactors TeSys™ F Contactors Overload Relay Accessories TeSys GV3P TeSys U 18-13 18-14 18-16 18-19 18-21 TeSys H TeSys™ D and F Overload Relays 18-21 Motor Starters and Protectors 18-22 TeSys™ U Open Motor Starter TeSys™ U Enclosed Combination Starters TeSys™ H Ultra Compact Starters TeSys™ GV Manual Starters and Protectors TeSys™ GV Accessori
Contactors and Overload Relays TeSys™ K Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ K Non-Reversing Mini-Contactors LC1K09 LP4K09 Table 18.1: AC Operating Coils Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V Maximum Current (A) 575 V Inductive AC3 Resistive AC1 Continuous Current Rating (A) Type of Connection 0.5 1 1.5 1.5 3 3 6 20 10 Screw-clamp 0.5 1.5 2 3 5 5 9 20 20 Screw-clamp 1 2 3 3 7.
TeSys™ K Contactors and Overload Relays Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ K Overload Relays Table 18.8: Overload Relays for 3-Pole Contactors with Screw-Clamp Terminals Current Setting Range (A) 0.11 to 0.16 0.16 to 0.23 0.23 to 0.36 0.36 to 0.54 0.54 to 0.8 0.8 to 1.2 1.2 to 1.8 1.8 to 2.6 2.6 to 3.7 3.7 to 5.5 5.5 to 8 8 to 11.
Contactors and Overload Relays TeSys™ K Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us LP2K0910 Table 18.11: DC Operating Coils Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V Maximum Current (A) 575 V Inductive AC3 Resistive AC1 Continuous Current Rating (A) Type of Connection 1/2 1 1.5 1.5 3 3 6 20 10 Screw-clamp 1/2 1.5 2 3 5 5 9 20 20 Screw-clamp 1 2 3 3 7.5 10 12 20 20 Screw-clamp Auxiliary Contacts N.
TeSys™ K Contactors and Overload Relays Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us LC2K090045 Table 18.15: AC Operating Coils Maximum Horsepower Ratings Single-Phase Three-Phase 115 V 230 V 200 V 230 V 460 V 4-Pole Mini Contactor 1/2 1.5 2 1/2 1 1.5 2 575 V Resistive AC1 Continuous Current Rating (A) Type of Connection 5 5 9 20 20 Screw-clamp 7.5 10 12 20 20 5 7.
Contactors and Overload Relays TeSys™ D Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Catalog Number Interpretation Table 18.
TeSys™ D Contactors and Overload Relays Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Non-Reversing Contactors LC1D09 LC1D093 LC1D40A LC1D115 LRD22 LRD3 Table 18.22: TeSys D Contactors—3 or 4 Pole, Screw Terminal Connections Three-Phase 230 V 460 V 2 5 — — — — 3 7.5 — — — — 5 10 — — — — 7.5 15 — — — — 10 20 10 20 10 30 — — 15 40 20 40 — — 30 60 — — — — 30 60 40 75 50 100 — — 200 V 2 — — 3 — — 5 — — 7.
Contactors and Overload Relays TeSys™ D Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Overload Relays Table 18.24: TeSys D Overload Relays—Ambient Compensated, Bimetallic, Direct Mounting Current Setting Range (A) 18 0.10–0.16 0.16–0.25 0.25–0.40 0.40–0.63 0.63–1 1–1.6 1.6–2.5 2.5–4 4–6 5.
TeSys™ D Contactors and Overload Relays Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Reversing Contactors Each 3-pole device is prewired with line and load side power wiring for reversing applications. Each 4-pole device is prewired with load side power wiring. Table 18.27: TeSys D Mechanically-Interlocked Reversing Contactors Single-Phase LC2D25 E164862 CCN NLDX 115 V 1/3 — 1/2 — 1 — 2 — 2 2 3 — 3 5 — 7.5 — 7.5 — 230 V 1 — 2 — 3 — 3 — 5 5 5 — 7.
Contactors and Overload Relays TeSys™ F Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ F Catalog Number Interpretation Table 18.
TeSys™ F Contactors and Overload Relays Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ F Non-Reversing Contactors Table 18.
Contactors and Overload Relays TeSys™ F Contactors and Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ F Reversing Contactors Components are available for customer assembly of TeSys F reversing contactors. For example, the following components must be ordered to build a reversing contactor, 75 hp @ 460 V, with a 120 V / 60 Hz coil: Table 18.
TeSys™ K Contactors Contactor Accessories Refer to Catalog MKTED210011EN www.se.com/us TeSys™ K Contactors Table 18.40: Instantaneous Auxiliary Contact Blocks LA1KN22 Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors Auxiliary Contacts Catalog Type of connection Number N.O. N.C.
Contactor Accessories TeSys™ D and F Contactors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D and F Auxiliary Contacts, Time Delay, Mechanical Latch Table 18.47: Standard, Instantaneous Auxiliary Contact Blocks Snap-On Mounting Contact Arrangement N.O. N.C.
TeSys™ D and F Accessories Contactor Accessories Refer to Catalog MKTED210011EN www.se.
Contactor Accessories TeSys™ D Contactors Refer to Catalog MKTED210011EN www.se.com/us RC and Varistor Coil Suppressors RC Coil Suppressor • Limitation of transient voltage to 300% of nominal voltage maximum. • Oscillating frequency limited to 400 Hz maximum. Slight increase in drop-out time (1.2–2 times normal). Table 18.
TeSys™ D Contactors Contactor Accessories Refer to Catalog MKTED210011EN www.se.com/us Bidirectional Diode Coil Suppressor • • Protection provided by limiting the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks Table 18.
Contactor Accessories TeSys™ D Contactors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Reversing Contactors Table 18.66: Contactors Reversing contactors comprising two identical, horizontally mounted contactors: Mechanical interlock With incorporated Without electrical interlock electrical (2 N.C.
TeSys™ F Contactors Contactor Accessories Refer to Catalog MKTED210011EN www.se.com/us TeSys™ F Component Parts and Vertical Mounting Table 18.67: Component Parts for the Assembly of F-Line 3-pole Reversing Contactors Set of Power Connections Cat. No. Mechanical Interlock Kit Cat. No.
Contactor Accessories TeSys™ F Contactors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ F Contactors Table 18.
TeSys™ D and F Overload Relays Overload Relay Accessories Refer to Catalog MKTED210011EN www.se.com/us TeSys D Overload Relay Accessories Table 18.75: Mounting Kits and Plates[1] Description Separate mounting kits for mounting to 35 mm DIN rail or for panel mounting with screws Mounting plates for screw mounting at 110 mm (4.3 in.
Motor Starters and Protectors TeSys™ U Open Motor Starter Refer to Catalog MKTED210011EN www.se.com/us TeSys™ U Motor Starter 1 The TeSys U motor starter is integrated, making it simple to choose and install. It consists of a control unit snapped in a power base. TeSys U can be configured to fit specific applications as well. Optional accessories include a reverser, a current limiter, predictive maintenance options, and communication options. For detailed information about TeSys U, visit our website.
TeSys™ U Open Motor Starter Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us Control Units and Functions Table 18.
Motor Starters and Protectors TeSys™ U Open Motor Starter Refer to Catalog MKTED210011EN www.se.com/us TeSys™ U Simple Motor Starter Table 18.89: Line Phase Barrier (optional) [8] Description Incoming line phase barrier to allow the TeSys U to be used as a self-protected combination starter according to UL508 Type E Cat. No. LU9SP0 Table 18.90: Reverser Line Phase Barrier Control Connection Max.
TeSys™ U Open Motor Starter Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us Accessories Table 18.97: Communication Modules [19][20] Communication modules allow the TeSys U starter to be connected directly to the network. They are for use with advanced or multi-function control units (24 Vdc only) and require a separate 24 Vdc power supply.
Motor Starters and Protectors TeSys™ U Enclosed Combination Starters Refer to Catalog MKTED210011EN www.se.com/us 1. Choose a base configuration Table 18.100: Base Configurations Ratings Max. HP Motor Voltage (V) Max.
TeSys™ U Enclosed Combination Starters Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us 2.1 Choose the thermal overload protection type Table 18.
Motor Starters and Protectors TeSys™ U Enclosed Combination Starters Refer to Catalog MKTED210011EN www.se.com/us 3. Choose the Control Power Source Table 18.
TeSys™ U Enclosed Combination Starters Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us 5.1 Abbreviated Forms Abbreviated forms are defined combinations of the most commonly ordered standard forms and are part of the profiled configurations with short lead time. For example, abbreviated form CP1 is a combination of standard forms C and P51. Abbreviated forms cannot be mixed with other standard forms, with the exceptions of forms S and S6.
Motor Starters and Protectors TeSys™ U Enclosed Combination Starters Refer to Catalog MKTED210011EN www.se.com/us Self-Protected Combination Starters Table 18.108: 22 mm Standard LED Pilot Light Forms Factory Modifications Red ON Green OFF White—Not Factory wired Blue—Not Factory wired Amber Overload Trip Yellow SSC Trip Red OFF Green ON Green Forward/Reverse Red Forward/Reverse Form P51 P52 P54 P56 P68 P69 P91 P92 P95 P96 Table 18.
TeSys™ H Ultra Compact Starters Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us Table 18.117: Soft Starter Forms [27] Factory Modifications Form H1 H2 H3 H4 H5 Motor FLA < 6A 6 < Motor FLA < 9A 9 < Motor FLA < 12A 12 < Motor FLA < 22A 22 < Motor FLA < 32A Table 18.118: Distributed 6 Input/6 Output Modicon STB with Communication Forms [28] Factory Modifications Form W10 W11 W12 W13 W14 DeviceNet Bus Modbus TCP Bus Ethernet IP Bus CANOpen Bus Profibus Bus Table 18.
Motor Starters and Protectors TeSys™ GV Manual Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ GV Family The TeSys GV family of products are 3-pole, horsepower rated, UL 508 listed manual starters. They include a manual disconnect, class 10 ambient-compensated thermal overload relay, and instantaneous, magnetic trip mechanism in one compact unit. Any GV manual starter can be used alone for local manual control of a motor with individual full-load currents up to 220 A.
TeSys™ GV Accessories and Enclosures Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ GV2 Accessories and Enclosures Table 18.125: GV2 Mounting Accessories Description Application Common mounting plate Adapter plate Combination block GV2GH7 7.
Motor Starters and Protectors TeSys™ GV Accessories and Enclosures Refer to Catalog MKTED210011EN www.se.com/us Table 18.130 GV2 Enclosures Accessories (cont'd.
TeSys™ GV Manual Starters and Protectors Motor Starters and Protectors Refer to Catalog 2520CT0001 www.se.com/us GV2P + LC1D Pre-Assembled Kits Simplify your life! These new pre-assembled kits come with a GV2P manual motor protector already connected to an LC1D contactor. Panel builders and end users can now save wiring time by purchasing the pre-assembled kits. Table 18.131: Pre-Assembled Kits Overload Relay Trip Range 0.16–0.25 A 0.25–0.40 A 0.40–0.63 A 0.63–1 A 1–1.6 A 1.6–2.
Motor Starters and Protectors TeSys™ GV Manual Starters and Protectors Refer to Catalog 2520CT0001 www.se.com/us Table 18.134: Auxiliary Contact Blocks [37] Mounting Location Description Max. No. of Blocks Front [38][39] 1 Left Hand Side 2 Instantaneous auxiliary contacts GV2 or GV3P GVAE11 Fault signaling contact + instantaneous auxiliary contact GV2 or GV3P Left Hand Side [42] 1 Short circuit signaling contact GV2 or GV3P Left Hand Side 1 Sold in lots of 1 10 1 1 1 Contact Type N.O.
Motor Circuit Protectors Motor Starters and Protectors Refer to Catalog 0680CT1701 www.se.com/us Table 18.
Motor Starters and Protectors Motor Circuit Protectors Refer to Catalog 0680CT1701 www.se.com/us TeSys BV4 Motor Circuit Protection Selection Providing UL508 type D combination ratings in accordance to current NEC installation requirements, the TeSys BV4 motor circuit protector allows for compact motor protection in conjunction with both the TeSys and Square D NEMA product families for motor control.
Motor Circuit Protectors Motor Starters and Protectors Refer to Catalog 0680CT1701 www.se.com/us Table 18.143 TeSys BV4 Rotary Operated Handles (cont'd.
Motor Starters and Protectors Motor Circuit Protectors Refer to Catalog 0680CT1701 www.se.com/us Table 18.144 TeSys BV4 Cabling and Locking Accessories (cont'd.) Accessory Catalog Number LV426990 One Time Torque Limiters, Green - 9 N.m (set of 6) LV426992 One Time Torque Limiters, Yellow - 5 N.
TeSys™ D Enclosed Starters Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Enclosed LE Starters — Family Catalog Number Interpretation Table 18.145: Catalog Number Interpretation for LE Starter Family Contactor Size 1 FVNR D09 7.
Motor Starters and Protectors TeSys™ D Enclosed Starters Refer to Catalog MKTED210011EN www.se.com/us Enclosed TeSys™ D Starters TeSys D enclosed full-voltage starters are available in Type 1 and Type 12/3R enclosures. The enclosed TeSys D offer accepts standard TeSys D accessories and all Insta-Kits control units and control power transformer kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure.
TeSys™ D Enclosed Starters Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us Table 18.149 Overload Relay Range (Select code from below) [18.149] (cont'd.) Code 17–25 17–25 17–25 23-28 23–32 23–32 30–40 37–50 30–38 30–40 37–50 48–65 55–70 63–80 48–65 For use on Contactors D25–D32 [52] D80 D40, D50, D65 D25–D32 [53] D25–D32 D40, D50, D65 D40, D50, D65 D40, D50, D65 D80 D80 D80 D80 D65–D80 D65–D80 D40, D50, D65 LE1D093A62 Base Catalog No. See Table 18.146 or Table 18.
Motor Starters and Protectors TeSys™ D Enclosed Combination Starters Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Enclosed—Fusible, Circuit Breaker, and Non-Fusible IEC combination starters combine the requirements of motor overload and short circuit protection in one convenient compact package. All devices provide Type 2 Coordination through 30 hp at 460 V. Devices are available in Type 1 and Type 12/3R enclosures.
TeSys™ D Enclosed Combination Starters Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us Table 18.154: Enclosed Full Voltage Reversing Circuit Breaker Combination Starters[61] Maximum Three-Phase Horsepower Ratings 200 V 2 3 7.5 10 10 15 20 25 30 40 230 V 2 3 7.5 10 10 15 20 30 40 50 460 V 5 7.5 15 20 30 40 40 60 75 100 575 V 7.5 10 20 25 30 40 50 60 75 100 Auxiliary Contacts Each Contactor N.O. N.C.
Motor Starters and Protectors TeSys™ D Enclosed Combination Starters Refer to Catalog MKTED210011EN www.se.com/us Factory Modifications and Insta-Kits Selection Add the factory modification code to the end of the catalog number created from page 18-42. With the use of Insta-Kits, only one operator scheme is allowed. Only the combinations of operators and pilot lights shown below can be ordered. Pilot lights will be at the coil voltage indicated in the catalog number for the starter.
TeSys™ D Enclosed Combination Starters Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us Table 18.158: Factory Modifications for Two Operators on Cover Symbol Description Color Nameplate Assembly by Suffix/Cat. No.
Motor Starters and Protectors TeSys™ D Enclosed Combination Starters Refer to Catalog MKTED210011EN www.se.com/us Table 18.
TeSys™ D Enclosed Combination Starters Motor Starters and Protectors Refer to Catalog MKTED210011EN www.se.com/us Table 18.164: Factory Modifications for Meters Symbol Assembly by NEMA Type 1 and 12 Suffix/Cat. No. Ammeter 3.5” panel type c/w 5 amps. C.T. and 2 controls terminals Factory A135 Voltmeter 3.5” panel type c/w 0-750 Volts max. c/w 2 x 600V terminals Factory A140 Factory A138 Factory A136 Factory A137 Description For Starter Elapsed time meter 3.
Motor Starters and Protectors TeSys™ LS1 Fuse Holders Refer to Catalog MKTED210011EN www.se.com/us TeSys™ LS1 Fuse Holders • • • • • • 45 mm wide (same dimensions as GV2ME) Available with screw clamp and spring type terminals Mounts directly to LC1D09–D38 contactors (with use of GV2AF3 or GV2AF4) Meets application needs for fusible starter Uses GV2AE instantaneous contact blocks to open control circuits DIN rail mounted Table 18.166: TeSys LS1 Fuse Holders CC, KTK-R Dimensions in. mm 0.41 x 1.5 10.
ATSU01 Altistart™ and TeSys™ U Soft Starter Module ATSU01 Refer to Catalog MKTED210011EN www.se.com/us Altistart Drive and TeSys U Motor Starter Table 18.169: Soft Start / Soft Stop Unit for 0.75 to 15 kW Motors (can be combined with the TeSys U starter) Motor Motor Power, hp[1] Starter 230 V 460 V 3-phase supply voltage: 200 to 480 V 50/60 Hz 1 2 1.5 3 2 5 3 7.5 5 10 7.
Replacement Parts TeSys™ D AC Coils Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D—AC Coils Table 18.172: For LC1D09–D38, LC1DT20–DT40 Contactors and CAD Relays LX1D2 18 Rated Nominal Voltage 12 21 [1] 24 32 36 42 48 60 100 110 115 120 127 200 208 220/230 230 230/240 277 380/400 400 415 440 480 575 600 Specifications Average consumption - Inrush (inductance 0.75) - Sealed (inductance 0.
Replacement Parts TeSys™ D AC Coils Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D—AC Coils LX1D6 Table 18.173: For Old D2 Style LC1D40, D50, D65, D80, and D95; For TeSys D LC1D40A, D50A, D65A, DT60A, and DT80A; For TeSys D LC1D115 and D150 Specification Average consumption -inrush (inductance 0.75) -sealed (inductance 0.
Replacement Parts TeSys™ F AC Coils Refer to Catalog MKTED210011EN www.se.com/us Application Note on Contactor Drop-out Times Contactors using LX1, FH, FJ, FK, FL, and FX coils have longer drop-out times. For critical applications such as emergency stop functions: • Select a fast drop-out coil (LX9), or • Use a maintained contact Stop button, or • Use an interposing relay. Table 18.
Replacement Parts TeSys™ D DC Coils Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D—DC Coils NOTE: DC coils for new TeSys D contactors LC●D09-D38, LC1DT20-DT40, LC●D40A-65A, LC1DT60A-80A, and LC●D80-D95 are not replaceable. Table 18.
Replacement Parts TeSys™ F DC Coils Refer to Catalog MKTED210011EN www.se.com/us TeSys F—DC Coils LX4 coils are the standard coils when a voltage code is added to the part number. The LX9 coils may be ordered separately for special applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block with an N.O. contact should be added to the contactor. Both the LX4 and LX9 coils can be used on previous TeSys F devices. Table 18.
Replacement Parts TeSys™ F Contactors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ F Contact Kits, Arc Chambers Table 18.
Wiring Systems Splitter Boxes, Power Connections, and Accessories Refer to Catalog MKTED210011EN www.se.com/us Splitter Boxes, Power Connections and Accessories Table 18.183: Splitter Boxes [1] Description Type of ControlCommand Connection on Control System Side No. of I/O per Starter — — 50 A power splitter box 1 x HE10, 8 I / 8 O 1 x HE10, 16 I and 1 x HE10, 8 O APP2R4H1 50 A power and control splitter box No.
TeSys™ AK5 Panel Busbar System Wiring Systems Refer to Catalog LVYED213001EN www.se.com/us TeSys™ AK5 Panel Busbar System The AK5 pre-fabricated bus bar system provides a quick and easy method of mounting control devices. All components are finger safe, UL Listed, CSA approved and CE marked. Although the AK5 system can be screw mounted onto any type of support, it must be mounted on the AM1DL201 DIN rail when component mounting plates incorporating a tap-off are used.
Dimensions TeSys™ D Non-Reversing Contactors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Contactors, AC and DC Coil Table 18.193: TeSys D 9 to 38 A Contactors, AC and DC Coils LC1D25 to D38 (3-pole) and LC1DT20 to DT40 (4–pole) LC1D09 to D18 Minimum electrical clearance Minimum electrical clearance 1.73 44 b1 b b LA4 c .39 10 .39 10 c1 c2 c3 b b1 c c3 D093 to D123 in. (mm) D099 to D129 in. (mm) AC coil, without add-on accessories DC coil AC coil, with LAD4BB 3.03 (77) 3.
Dimensions TeSys™ D Non-Reversing Contactors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Contactors, DC Coil LC1D80, D95 (3P), LP1D80004, D80008 (4P) Minimum electrical clearance LC1 1.261.73 32 44 LA4 a b1 b1 5 (127) c c1 c2 c3 .47 12 c c1 c2 c3 5 (125) (LAD 8) a 5 (125) (LAD 8) LC1D115, D150 (3P), LC1D115004 (4P), AC and DC Coils Panel mounted with 1/4” screws a LA4 6.
Dimensions TeSys™ F Non-Reversing Contactors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ F Contactors, Dimensions All dimensions shown in mm. To convert to inches, divide by 25.4. Table 18.197: LC1F115–F330 Dimensions LC1F115 to F330 F115 S LC1 s1 = b b2 M X1 = X1 Q L P Q1 P a c (1) Protective cover Type LA9F70• f F150 3-Pole 4-Pole F185 34Pole Pole 168.5 208.5 174 174 137 137 305 305 176 176 130 130 111 151 80 80 106 106 120 120 113.5 113.5 154 154 40 40 29 29 59.5 59.
Dimensions TeSys™ F Non-Reversing Contactors Refer to Catalog MKTED210011EN www.se.com/us Table 18.201: LC1F Dimensions LC1F630 and LC1F800 6 x M12 x 45 = 11.02 280 18.28 464 10.39 264 11.97 304 7.09 180 = c 4 x Dia. 10.5 mm 2.52 64 1.57 40 = 2.83 72 G J1 = 2.38 60 X1 Q 6.10 155 9.84 250 7.76 197 3.15 80 3.15 80 Q1 7.13* 181 a X1: Minimum clearance according to the operational voltage and the breaking capacity. LC1F630 2P 3P 4P a 12.17 12.17 15.31 G supplied 7.09 180 7.
Dimensions TeSys™ D Reversing Contactors Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Reversing Contactor Dimensions Table 18.202: Reversing Contactor Dimensions LC2D09–D38 2 x LC1D09 to D38 LC2DT20 to DT40 2 x LC1 DT20 to DT40 2xM4 = 2.36/2.76 60/70 b c = G = a = = G = e2 c e2 b 2.36/2.76 60/70 = e1 2xM4 = a a in. (mm) b in. (mm) c [4] in. (mm) e1 in. (mm) e2 in. (mm) G in. (mm) LC2 or 2 x LC1 a in. (mm) b in. (mm) c in. (mm) G in. (mm) D09 to D18 3.
Dimensions TeSys™ D Reversing Contactors Refer to Catalog MKTED210011EN www.se.com/us e2 = 5.12 130 6.22 158 = e1 LC2D115 and D150 2 x LC1D115 and D150 = c LC2 or 2 x LC1 D115, D150 D115004 c, e1 and e2 includes cabling G = a a in. (mm) 10.47 (266) 13.15 (334) c in. (mm) 5.83 (148) 5.83 (148) e1 in. (mm) 2.2 (56) — e2 in. (mm) 0.71 (18) 2.36 (60) G in. (mm) 9.53/10.08 (242/256) 12.2/12.
Dimensions TeSys™ D Open Starters Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Open Starter Dimensions Table 18.203: TeSys D Thermal Overload Relay Dimensions, in. (mm) LRD04L-32L Direct mounting beneath contactors with screw clamp connections LRD013-223 Direct mounting beneath contactors with spring terminal connections c b DB415912.eps LRD01-35 Direct mounting beneath contactors with screw clamp connections 3 76.1 LC1● b c D09–D18 D25–D38 4.84 (123) 5.39 (137) See page 18-60 1.
Dimensions TeSys™ D Open Starters Refer to Catalog MKTED210011EN www.se.com/us LRD33●●● Direct mounting beneath contactors LC1D80 to D95 AM1● d DL201 0.28 (7) b 4.55 (115.5) 4.55 (115.5) LP1D80 4.55 (115.5) g (4P) 0.37 (9.5) 0.37 (9.5) 0.87 (22) 0.37 (9.5) 0.87 (22) — 6.85 174 5.20 132 DL200 and DR200 0.10 (2.5) DE200 and ED●●● 0.41 (10.5) AM1 d DP200 and DR200 0.10 (2.5) 4.72 120 DE200 and ED●●● 0.41 (10.
Dimensions TeSys™ D Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Thermal Overload Relay Dimensions LRD01–35 Independent mounting on 1.97 in. (50 mm) centers or on rail AM1DP200 or DE200 DF533590.eps Independent mounting on 4.33 in. (110 mm) centers 2xØ6.5 1.81 46 = = .59 15 = LAD 7B205 4.33 110 = 125 0.24 5 4.92 1.97 50 85 1.77 45 DX1 AP25 AM1 d DP200 0.08 (2) 2xØ6.5 DE200 0.37 (9.
Dimensions TeSys™ D Overload Relays Refer to Catalog MKTED210011EN www.se.com/us LR9D01–D32 LR9D110S 1.38 35 0.39 10 d 4.49 114 AM1 d d 2xØ4.5 DP200 0.08 (2) LA7 D03 (1) DF533595.eps 2.95/3.42 75/87 0.08 2 2.03 51.5 4.76 121 2xØ4.5 LRD3●●●, LR2D35●●, and LR9D5 Remote tripping or electrical reset 2.95 = 1.97 75 = 50 3.94 100 DF533594.eps LRD3●●● and LR2D35●● Independent mounting on 1.97 in. (50 mm) centers or on rail AM1DP200 or DE200 LA7 D3064 2.95/3.42 75/87 4.72 120 2.03 51.5 1.
Dimensions TeSys™ F Overload Relays Refer to Catalog MKTED210011EN www.se.com/us TeSys™ F Overload Relay Dimensions All dimensions shown in mm. To convert to inches, divide by 25.4. Table 18.204: TeSys F Overload Relay Dimensions 1.97 50 4.72 120 1.97 50 1.85 47 2.36 60 LR9F7●81, F81 (for mounting beneath LC1F630 and LC1F800) P2 Ø11 1.18 30 4xØ5.5 3.15 80 7.87 200 3.15 80 Ø13 7.44 189 4.29 109 3.23 82 5.39 137 2.44 62 1.57 40 5.94 151 .98 25 2.05 52 2.60 66 9.02 229 2.05 52 2.
Dimensions TeSys™ D Enclosed Starters and Combination Starters Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D Combination Starter Dimensions Table 18.205: Non-Combination Starter Dimensions [6] A 13 .50 Non-Combination Starters .75 E B 19 J K C R F G H Provision for 1/4" Screw D 14 .56 D/2 Type 1 Non-Reversing D09-32 D40-65 D80 Reversing — D09-32 D40-80 A 6.77 8.66 10.63 B 10.04 10.83 13.98 C 6.25 7.21 7.21 D 5.38 7.25 9.22 E 9.00 9.75 12.94 Type 12/3R F 1–1.25 1.25–1.
Dimensions TeSys™ D Enclosed Starters and Combination Starters Refer to Catalog MKTED210011EN www.se.com/us TeSys™ D LE1 and LE2 Starter Dimensions Table 18.207: FVNR and FVR Starters—LE1 and LE2[7] C B A Figure 1 C 18 CONTACTORS AND STARTERS-IEC B Catalog No.
TeSys™ D Enclosed Starters and Combination Starters Dimensions Refer to Catalog MKTED210011EN www.se.com/us Table 18.208: Combination FVNR and FVR Starters — LE1 and LE2[8] B R A Depth (C) 193 193 193 193 193 193 233 233 252 193 193 193 193 193 193 193 193 200 193 193 193 193 193 233 233 233 252 193 193 193 193 193 233 233 233 233 18 Figure 3 Catalog No. Figure No.
Dimensions TeSys™ K Contactors, Overload Relays and Starters Refer to Catalog MKTED210011EN www.se.com/us TeSys™ K Contactor Dimensions Table 18.209: TeSys K Contactor Dimensions LR2K Direct mounting under the contactor Separate mounting with LA7-K0064 terminal block on 35 mm rail (AM1DP200 or AM1DE200) 1.38 35 4.57 116 3.15 80 1.50 38 4 x Ø4 1.97 50 .31 8 2.28 58 2.95 75 3.09 (DP200) 78 3.38 (DE200) 86 2.56 65 1.77 45 13 A1 13 5 3 Wiring Scheme 1 Three-phase 1.
Dimensions TeSys™ U Open Motor Starters Refer to Catalog 8502CT0201 www.se.com/us TeSys™ U Starter Dimensions Table 18.210: TeSys U Starter Dimensions Starter Controllers Non-Reversing [9] Reversing Rail Mounting Screw Mounting 29 126 4.96 X1 1.14 30 Ø4 .15 1.18 135 5.31 X1 163 6.42 120/125 4.72/4.92 154 6.06 73 2.87 X2 45 X2 1.77 Ø4 .15 224 8.82 126 4.96 Screw Mounting 135 5.31 233 9.17 Rail Mounting 45 1.
Dimensions Soft Starter Module ATSU01 Refer to Catalog MKTED210011EN www.se.com/us Altistart U01 and TeSys U Soft Starters, Mounting Table 18.211: Altistart U01 and TeSys U Soft Starters TeSys U Combination (non-reversing power base) and ATSU01N212LT Mounting on (35 mm) rail with VW3 G4104 connector 45 1.77 TeSys U Combination (non-reversing power base) and ATSU01N222LT to ATSU01N232LT Mounting on (35 mm) rail with VW3G4104 connector 170 6.69 314 12.36 284 11.18 150 5.91 45 1.77 9 0.354 18 9 0.
Dimensions TeSys™ GV Manual Starters and Protectors Refer to Catalog 2520CT0001 www.se.com/us TeSys GV2 and GV3 Manual Starter and Protector Dimensions Table 18.212: TeSys GV2 and GV3 Manual Starter and Protector Dimensions GV2AD, AM, AN, AU, AS, AX Mounting of GV2M GV2AE Block GV2AD, AM, AN Block GV2AU, AS, AX 44.5 1.75 44.5 1.75 9.3 .37 9.3 .37 81 3.19 18 .71 c GV2AD, AM, AN, AU, AS, AX GV2P On 35 mm rail C = 98.5 mm (3.88") on AM1DP200 (35 x 7.5 mm) C = 106 mm (4.
Dimensions TeSys™ GV Manual Starters and Protectors Refer to Catalog 2520CT0001 www.se.com/us Table 18.213: TeSys GV2 and GV3 Manual Starter and Protector Dimensions (cont’d) GV2M with GV2AF01 and LC1K Adapter Plate GK2AF01 GV2M with GV2AF01 and LC2K Dimensions (mm) 5 .2 35 1.38 GV2M with GK2AF01 and LC1K 45 1.77 GV2M on panel with GV2AF02 adapter plate Door cut-out 4xØ3.5 Ø43 0.14 1.7 4.2 .17 = 54 2.13 = 1.5...5/0.06...0.20 min.=150 max.=290 5.91 11.42 = = 54 2.13 5.2 0.
Dimensions TeSys™ GV Manual Starters and Protectors Refer to Catalog 2520CT0001 www.se.com/us TeSys GV7 Manual Starter and Protector Dimensions Table 18.214: TeSys GV7 Manual Starter and Protector Dimensions 1 GV7R Flush Mounting Side by Side 4.92 125 = 4.25 108 4.25 108 = = 1.85 3.0 47 76 = 2xØ0.24 2xØ6 = Panel Mounting 1.14 29 3.27 83 == 1.14 29 = = 4.25 108 U < 440 V 440 V < U < 600 V x1 in. (mm) 0 (0) 0.20 (5) 0.39 (10) x2 in. (mm) 1.18 (30) 1.38 (35) 1.38 (35) U > 600 V 0.
Dimensions TeSys™ GV Manual Starters and Protectors Refer to Catalog 2520CT0001 www.se.com/us 1.61 41 GV7AC03 Spreaders 4.49 114 1.77 1.77 45 45 1.18 30 Cabling Smooth Terminals Z GV7R● GV7R●220 2.76 70 X a (in./mm) 0.77/19.5 0.85/21.5 Connectors Z 0.75 19 0.41 10.5 a 2.76 70 Z X X GV7AP03, GV7A04 Direct Rotary Handle 1.77 2.87 45 73 I 60 DD 60 1.85 3.0 47 76 Flush Mounting 18 0 1.10 28 GV7AP03 or GV7AP04, GV7AP05 Direct Rotary Handle 4.76 121 3.58 91 2.17 55 3.5 89 1.