Full Product Manual
Table Of Contents
- Section 1 Load Centers
- EZ Selector - Selection Assistance
- QO™ Miniature Circuit Breakers
- QO™ Load Centers
- Homeline™ Miniature Circuit Breakers
- Homeline™ Load Centers
- QO/Homeline Load Center Value Packs and Accessories
- QO/Homeline Load Center Dimensions
- Combination Service Entrance Devices
- Solar Ready PoN CSEDs
- Wiser Energy™ and Wiring Devices
- Enclosed Devices
- Servicepak™ Power Outlet Panels
1-50
© 2022 Schneider Electric
All Rights Reserved
March 1, 2022
Servicepak
™
Power Outlet Panels
www.se.com/us
Class 1140
1
LOAD CENTERS
Power Outlet Panels for Construction Sites
•
Provide temporary power at construction sites.
•
Each receptacle protected by QO-GFI circuit breaker in compliance with NEC
®
requirements.
•
Each enclosure is rainproof.
•
10 kA short circuit current rating.
•
UL Listed as suitable for use as temporary site service equipment.
•
Provided with neutral bonding provisions.
•
Boxes have provisions for type “B’’ hubs to be field-installed.
Table 1.100: Construction Site Panels
Power
Outlet
Configuration
Service
[1]
Mains
Ampere
Rating
Circuit Breaker
(Included)
Receptacles
(Included)
Cat. No. [2]
Main Wire
Size
AWG [3]
A C D E F Cu Al
1C 1Ø2W 40 A
(1) QO120GFI
1 PAK10C1
OBS
14–6 12–6
2C 1Ø2W 40 A
(2) QO120GFI
2
PAK11C [4]
14–6 12–6
2C 1Ø2W 40 A
(2) QO120GFI
2 PAK11C1 14–6 12–6
3C 1Ø3W 70 A
(1) QO120GFI
(1) QO230GFI
1 1 PAK31CGFI 8–1 8–1
4C 1Ø3W 70 A
(1) QO120GFI
(1) QO220GFI
1 1 PAK36C1GFI 8–1 8–1
5C 1Ø3W 70 A
(1) QO120GFI
(1) QO250GFI
1 1 PAK51CGFI 8–1 8–1
6C 1Ø3W 70 A
(1) QO120GFI
(1) QO250GFI
1 1 PAK55CGFI 8–1 8–1
7C 1Ø3W 70 A
(2) QO120GFI
(1) QO220GFI
2 1 PAK72CGFI 8–1 8–1
8C 1Ø3W 70 A
(2) QO120GFI
(1) QO250GFI
2 1 PAK76CGFI 8–1 8–1
9C 1Ø3W 100 A
(1) QO120GFI
(2) QO250GFI
1 2 PAK1004CGFI 14–1 12–1
OBS
This product is obsolete.
Power Outlet Panels for Recreational Vehicle Parks
20 A 125 V 2W and Grd.
NEMA 5-20R
30 A 125 V 2W and Grd
ANSI 73.13
50 A 125/250 V 3W and Grd.
NEMA 14-50R
20 A 250 V 2W and Grd.
NEMA 6-20R
30 A 125/250 V 3W and Grd.
NEMA 14-30R
50 A 250 V 2W and Grd.
NEMA 6-50R
All non-pedestal devices have provisions to field-install a Type “B’’ hub
on the bottom endwall for bottom feed from a conduit riser. Order Type
“B’’ bolt-on hub (B250 Max.) and two mounting screws
(Cat. No. 8002505501) and two hex nuts (Cat. No. 2340102000).
•
Provide electrical power to individual recreational vehicle park sites.
•
Each receptacle protected by appropriate GFI or Standard QO
™
circuit breaker.
•
All receptacles and circuit breakers included.
•
10 kA short circuit current rating.
•
UL Listed.
•
All enclosures are rainproof.
•
No neutral bonding provisions.
•
Loop-feed provisions.
Table 1.101: Recreational Vehicle Park Panels
Power Outlet
Configura-
tion
Serv-
ice
[1]
Mains
Am-
pere
Rating
Circuit Breaker
(Included)
Receptacles
(Included) [5]
Cat. No.
Main Wire Size
AWG/kcmil [6]
Phase and Neutral
A B C Cu Al
Underground or Overhead Loop-Feed Terminals—Non-Pedestal [2] [7]
11C 1Ø2W 40 A
(2) QO120GFI
2 PAK11CTG 14–6 12–6
12C 1Ø2W 50 A
(1) QO120GFI
(1) QO130
1 1 PAK41CTGFI
12–1
(2) QO130
1 1 PAK41CTG
14C 1Ø3W 100 A
(1) QO120GFI
(1) QO250
(1) QO130
1 1 1
PAK75CTGFI
(Not Loop Feed)
14–1 12–1
(1) QO250
(2) QO130
1 1 1
PAK75CTG
(Not Loop Feed)
Pedestal Mounted—Underground Loop-Feed Terminals [8]
11C 1Ø2W 40 A
(2) QO120GFI
2 PAK11PG
(2) 6–250
[1] (1Ø2W 120 Vac) (1Ø3W 120/240 Vac)
[2] Devices have a bolt-on factory-installed closing cap. Order type “B’’ bolt-on hub separately from page 1-18.
[3] Equipment ground terminal suitable for (2) 14 or 12 AWG Cu or (2) 12 or 10 AWG Al.
[4] Receptacles in this device are in bottom endwall and are accessible with outer door padlocked. “Order Only’’ from Lexington—Minimum order quantity is 50 devices.
[5] 20 A receptacles protected by 20 A GFI circuit breaker.
[6] Two wires each per phase, neutral, and equipment ground—for loop feed (except PAK75CTG).
[7] Equipment ground terminal suitable for (2) 14–12 AWG Cu or (2) 12–10 Al.
[8] Equipment ground terminals suitable for (2) 10–2/0 AWG Cu or (2) 6–2/0 AWG Al.