Table of Contents Load Centers EZ Selector - Selection Assistance 1-2 QO™ Miniature Circuit Breakers 1-3 QO™ Load Centers 1-9 LOAD CENTERS Section 1 QO™ Load Centers Homeline™ Miniature Circuit Breakers 1-19 Homeline™ Load Centers 1-22 QO/Homeline Load Center Value Packs and Accessories 1-26 QO/Homeline Load Center Dimensions 1-32 Combination Service Entrance Devices 1-35 Solar Ready PoN CSEDs 1-43 Wiser Energy™ and Wiring Devices 1-46 Enclosed Devices 1-47 Servicepak™ Power Outlet
EZ Selector - Selection Assistance 1 Load Center EZ Selector - Selection Assistance www.se.com/us Class 1140 QO™ and Homeline™ Load Center EZ Selector - Selection Assistance LOAD CENTERS EZ Selector Steps to select a load center. 1. Select product type: • Homeline™ 1 inch format (HOM) • QO™ 3/4 inch format with plug-on neutral (QO) (P) • QO™ 3/4 inch format (QO) 2. Select enclosure type: indoor or outdoor (RB = rainproof) 3. Select single phase (1) or three phase (3) 4.
QO Plug-On Circuit Breakers QO™ Miniature Circuit Breakers Class 730, 731, 733 / Refer to Catalog: 0730CT9801 www.se.com/us Square D brand QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD and NQ panelboards, NQOD and NQ OEM interiors or Speed-D™ switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD and NQ panelboards or interiors.
QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers 1 Class 730, 731, 733 / Refer to Catalog: 0730CT9801 www.se.com/us QO/QOB Ring Terminal Table 1.2: QO/QOB Ring Terminal—Factory-Installed Only LOAD CENTERS Ampere Rating 10–30 A 35–60 A 35–50 A 70–110 A 60–100 A Poles 1, 2, 3 1,2 3 2 3 Suffix 5237 5238 5273 Wire Sizes for QO/QOB Circuit Breakers Table 1.
QO Plug-On Circuit Breakers www.se.com/us QO™ Miniature Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 Qwik-Gard™ circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping.
QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers 1 Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 www.se.com/us QO-EPD/EPE Circuit Breakers QO-EPD/EPE circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 mA level (EPD) or 100 mA level (EPE). They are not designed to protect people from electrical shock. LOAD CENTERS Table 1.
QO Plug-On Circuit Breakers www.se.com/us QO™ Miniature Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Table 1.
QO™ Miniature Circuit Breakers QO Accessories 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Accessories for QO/QOB Circuit Breakers Table 1.15: Accessories for use with QO and QOB Miniature Circuit Breakers Description Cat. No.
QO™ Load Centers QO Indoor Load Centers, 1Ø Class 736, 1130 / Refer to Catalog 1100CT0501 www.se.com/us Factory-installed electrical accessories take up an additional pole space on QO, QOGFI, QO-EPD, QO-SWN and QOU circuit breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available for QOB-VH (2P 150 A and 3P 110–150 A) circuit breakers or QO, QOU molded case switches. QO circuit breakers will accept only one accessory per circuit breaker.
QO™ Load Centers QO Indoor Load Centers, 1Ø 1 Class 736, 1130 / Refer to Catalog 1100CT0501 www.se.com/us Field-Installed Main Circuit Breaker Kits, 1Ø Table 1.
QO™ Load Centers QO Indoor Load Centers, 1Ø Class 736, 1130 / Refer to Catalog 1100CT0501 www.se.com/us Table 1.21: 1Ø Field-Installed Main Lug Kits—Use with Convertible Main Load Centers Only Main Lugs Rating [11] 125 A 125 A 225 A Cat. No.
QO™ Load Centers QO Load Centers, Rainproof, 1Ø 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us QO Load Centers with Included Cover (1Ø3W—120/240 Vac Indoor—UL Listed) Table 1.23: Load Centers with Included Cover (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) LOAD CENTERS Mains Rating 125 A Short Circuit Current Rating Spaces Max. 1P Circuits [15] Max.
QO Load Centers, Rainproof, 1Ø QO™ Load Centers Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us QO Plug-on Neutral Load Centers and CAFI circuit breakers are engineered for a quick Plug-on Neutral connection on every unit. Table 1.25: Convertible Main Breaker Plug-on Neutral Load Center (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) R A I N P R O O F [23] [24] [25] Spaces Max.
QO™ Load Centers Backup Power Solutions, 1Ø 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Backup Power Solutions (1Ø3W—120/240 Vac Backup Power—UL Listed) Table 1.26: Backup Power Solutions LOAD CENTERS Mains Rating (A) I N D O O R R A I N P R O O F Spaces Max. Single Pole Circuits [26] Max.
QO™ Load Centers QO Special Constructions, 1Ø QO Standard Load Center Main Lugs and Main Breaker, Fixed Mains (1Ø3W—120/240 Vac Special Applications—UL Listed) Table 1.28: Low Amperage Fixed Main Lugs Indoor Load Centers (Accepts Only QO Plug-on Circuit Breakers - Not compatible with QO Plug-on Neutral Circuit Breakers) Max. Max.
QO™ Load Centers QO Special Constructions, 1Ø 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us QO Standard Load Center Main Lugs, Fixed Mains (1Ø3W—120/240 Vac Rainproof—UL Listed) Table 1.31: Fixed Main Lugs Rainproof Load Centers (Accepts Only QO Plug-on Circuit Breakers - Not compatible with QO Plug-on Neutral Circuit Breakers) LOAD CENTERS Mains Rating R A I N P R O O F Spaces Max. Single Pole Circuits [49] Max.
QO™ Load Centers QO Special Constructions, 1Ø Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us Table 1.
QO™ Load Centers QO Indoor, Rainproof Load Centers, 3Ø 1 Class 1130 / Refer to Catalog 1100CT0501 www.se.com/us QO Standard Load Center Main Lugs and Main Breaker (3Ø4W—208Y/120 Vac, 3Ø4W—240/120 Vac Delta and 3Ø3W—240 Vac Delta—Indoor and Rainproof—UL Listed) LOAD CENTERS Table 1.36: Main Lugs and Main Breaker Load Centers (Accepts Only QO Plug-on Circuit Breakers - Not compatible with QO Plug-on Neutral Circuit Breakers) Main Max.
Homeline Plug-On Circuit Breakers Homeline™ Miniature Circuit Breakers www.se.com/us LOAD CENTERS Class 1170 / Refer to Catalog 1100CT0501 Homeline Standard Plug-On Circuit Breakers The Square D Homeline circuit breakers are in a 1 in. wide format for 1-pole circuit breakers. They are designed to plug into Homeline load centers. Table 1.
Homeline™ Miniature Circuit Breakers Homeline Plug-On Circuit Breakers 1 Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Homeline Dual Function Circuit Breaker (HOM-DF) Homeline Combination Arc Fault and Ground Fault Circuit Interrupters (Dual Function)— Provide overload and short circuit protection, plus arc fault and ground fault protection in a single device in accordance with the NEC, UL1699 and UL943. LOAD CENTERS Table 1.
Homeline Accessories www.se.com/us Homeline™ Miniature Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 Homeline Circuit Breaker Wire Sizes Table 1.
Homeline™ Load Centers Homeline Load Centers, Indoor, 1Ø 1 Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us HOM Standard Load Center Main Lugs, Fixed Mains (1Ø3W—120/240 Vac Indoor—UL Listed) LOAD CENTERS Table 1.50: Fixed Main Lugs Load Centers (Accepts Only HOM Plug-on Circuit Breakers - Not compatible with HOM Plug-on Neutral Circuit Breakers) Main Wire Size Max. Max.
Homeline™ Load Centers Homeline Load Centers, Indoor, 1Ø Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us Table 1.
Homeline™ Load Centers Homeline Load Centers, Indoor, 1Ø 1 Class 1170 / Refer to Catalog 1100CT0501 www.se.com/us 1Ø, Field-Installed Mains Kits Table 1.
Homeline™ Load Centers Homeline Load Centers, Rainproof, 1Ø Class 1170 / Refer to Catalog 1100CT0501 HOM Standard Load Center Main Lugs, Fixed Mains (1Ø3W—120/240 Vac Rainproof—UL Listed Table 1.58: Fixed Main Lugs Load Centers (Accepts Only HOM Plug-on Circuit Breakers - Not compatible with HOM Plug-on Neutral Circuit Breakers) Spaces Max. Single Pole Circuits [26] Max. Tandem Circuit Breakers Load Center Box, Interior and Cover Cat. No.
Value Packs 1 QO/Homeline Load Center Value Packs and Accessories www.se.com/us Class 1130, 1170 / Refer to Catalog 1100CT0501 Plug-on Neutral Indoor Load Center Value Packs Table 1.61: Plug-on Neutral Indoor Load Center Value Packs (Compatible with Plug-on and Plug-on Neutral Circuit Breakers) LOAD CENTERS Mains Rating Spaces Max. 1P Circuits [1] Max. Tandem Circuit Breakers Load Center Box, Interior, Cover and Branch Circuit Breakers Cat. No.
QO Load Center Accessories www.se.com/us QO/Homeline Load Center Value Packs and Accessories Class 1130 / Refer to Catalog 1100CT0501 Mains Rating Max. 1P Circuits Max.
1 QO/Homeline Load Center Value Packs and Accessories QO Load Center Accessories www.se.com/us Class 1130 / Refer to Catalog 1100CT0501 Table 1.65 QO Load Center Accessories (cont'd.) LOAD CENTERS Description For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that only one circuit breaker can be “ON’’ at a time.
Homeline Load Center Accessories www.se.com/us QO/Homeline Load Center Value Packs and Accessories Class 1130 / Refer to Catalog 1100CT0501 Table 1.67 QO Load Center Covers (cont'd.) Spaces 200A 30 42 42 225A QO Standard Covers Surface Gray Covers QOC342MQF QOC342MQS QOC342MQF QOC342MQS QOC342MQF QOC342MQS Flush Flush White Covers — — — QO Mono-Flat Covers Gray Covers — — — LOAD CENTERS Mains Rating White Covers — — — 1 Table 1.
1 QO/Homeline Load Center Value Packs and Accessories Qwik-Grip Load Center Accessories www.se.com/us Class 1130 / Refer to Catalog 1100CT0501 Table 1.
Surge Protective Devices www.se.com/us QO/Homeline Load Center Value Packs and Accessories Class 1130 / Refer to Catalog 1100CT0501 Description Cat. No.
Indoor Enclosure Dimensions and Knockout Information QO/Homeline Load Center Dimensions 1 Class 1130, 1170 / Refer to Catalog 1100CT0501 www.se.com/us Indoor Enclosure Dimensions and Knockout Information Table 1.73: Enclosure Dimensions LOAD CENTERS Box No. 1 2 3 4 5 6 7 8 9 10 11 12 W in. 3.81 4.81 4.81 8.88 14.25 14.25 14.25 14.25 14.25 14.25 14.25 14.25 Dimensions H in. mm 6.72 171 9.30 236 9.30 236 12.57 319 14.92 379 17.92 455 20.92 531 26.04 661 29.86 758 33.78 858 37.98 965 39.
Indoor Enclosure Dimensions and Knockout Information www.se.com/us QO/Homeline Load Center Dimensions Class 1130, 1170 / Refer to Catalog 1100CT0501 Table 1.75: Indoor Knockout Information and Enclosure Dimensions for Qwik Grip Loadcenters in. 14.25 14.25 14.25 14.25 14.25 14.25 7Q 8Q 9Q 10Q 11Q 12Q H mm 362 362 362 362 362 362 D in. 20.92 26.04 29.86 33.78 37.98 39.37 mm 531 661 758 858 965 1000 in. 3.75 3.75 3.75 3.75 3.75 3.
QO/Homeline Load Center Dimensions 1 Rainproof, Dimensions, Knockouts and Bolt-on Hubs Class 1130, 1170 / Refer to Catalog 1100CT0501 www.se.com/us Enclosure Dimensions and Knockout Information Table 1.76: Enclosure Dimensions Dimensions W LOAD CENTERS Box No. in. 6.52 4.88 8.88 14.75 14.75 14.75 14.75 14.75 14.75 4.56 6.92 7.56 9.62 6.92 14.75 8.88 8.55 8.
Catalog Number Logic for CSEDs Combination Service Entrance Devices Class 4119, 4120 www.se.
Combination Service Entrance Devices Rainproof, Meter Mains 1 Class 4119, 4120 www.se.
Rainproof, Meter Mains Combination Service Entrance Devices Class 4119, 4120 www.se.
Combination Service Entrance Devices 1 Rainproof, All-In-Ones, 100 to 225 A Maximum Class 4120 www.se.com/us Meter Mains and All-In-Ones (100 to 225 A Maximum) • • UL Listed, suitable only for use as service equipment Meets EUSERC standards Service disconnect(s) are supplied factory-installed, except where noted Semiflush-reverse design available, supplied with load center (indoor access) • • Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires.
Rainproof, All-In-Ones, 100 to 225 A Maximum Combination Service Entrance Devices Class 4120 www.se.com/us Ampere Rating (Max.) Circuits Tandems 200 A A300L Line Side Main Lugs AWG/ kcmil (Al/ Cu) Service Ground Lug AWG/ kcmil (Al/Cu) 6— 250 14 — 2/ 0 Weight Each (Lbs) and Pallet Qty. Square D™ Energy Center Semi-flush Mount Only UG 22 kA QOWC60M200PFY QOM2[41] 200 A 60 [42] 61 10 116,2 1 200 A LOAD CENTERS Type (Order separately [40]) Hub Type (Order separately [39]) Cat. No.
Combination Service Entrance Devices 1 Rainproof, Meter Mains and All-In-Ones, 300–400 A Class 4119, 4120 www.se.com/us Meter Mains and All-in-Ones (300–400 A Devices) • • • Meter Mains and All-in-Ones Ring or ringless type meter socket designs available UL Listed, suitable only for use as service equipment Meets EUSERC standards where indicated.
Rainproof, Meter Mains and All-In-Ones, 300–400 A Combination Service Entrance Devices Class 4119, 4120 www.se.com/us Table 1.
Combination Service Entrance Devices Dimensions for CSEDs Class 4119, 4120 1 www.se.com/us Dimensions for CSEDs Table 1.86: Knockouts 14.97 28.28 “A” Hub 380 718 LOAD CENTERS Symbol A B C D E F G H I J Conduit Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 (in.) ▲ Driphood supplied factory-installed and is required for surface mount installation. For semi-flush installation, remove driphood and install flange kit SC200F (order separately).
Rainproof, Meter Mains and All-In-Ones, 125 to 225 A Maximum Solar Ready PoN CSEDs Class 4120 www.se.com/us UL Listed, suitable only for use as service equipment • • • Meets Ferderal Specification W-P-115c as Type 1, Class 2 Solar ready kits for line side tap available, see accessories table All devices have a 3" KO in the bottom endwall Provisions for field installed CTs on All devices Load Center and Branch Circuit Breakers (Order seperately pages….
Solar Ready PoN CSEDs Circuit Breakers for CSEDs 1 Class 4119, 4120 www.se.com/us C,D,E,F A,B A 3.40 86 B,C 14.85 377 LOAD CENTERS 21/2" Max “A” Hub 5.80 147 21.50 546 SC3042M200PS 42.60 38.40 1006 SC42M200PS . 30/42 8/16 - 20/40 899 11.10 282 29.50 749 32.30 820 37.
Accessories and Hubs for CSEDs Solar Ready PoN CSEDs Class 4119, 4120 www.se.com/us Accessories and Hubs for CSEDs Cat. No. RCGK2 QCGK3 PK2SCPV OBS 5J MMHB 29007 2920910001 29008W ARP00026 MMLRK SU2X6TRIM SCBRLLOCK 1 Description Generator Kit: Interlocks main service disconnect and generator circuit breaker (order separately).
Wiser Energy™ and Wiring Devices Wiser Energy™ Smart Home 1 Class 4119, 4120 www.se.com/us Wiser Energy™ Home Power Monitor LOAD CENTERS Wiser Energy from Square D is an integral part of any smart home. With Wiser Energy, you can give your home a voice. It helps you keep tabs on your home by notifying you when devices are on or off in the home, and monitors home energy usage in real time, for a safer and more efficient home.
Enclosed Devices Service Entrance Devices www.se.
Enclosed Devices Non-Service Entrance Devices Class 1130 / Refer to Catalog 1100CT0501 1 www.se.com/us 1Ø3W—120/240 Vac—240 Vac—UL Listed Table 1.95: Enclosed Molded Case Switch, Switch Included, Does NOT provide overcurrent protection LOAD CENTERS Ampere Rating General Purpose Rainproof 240 Vac 60 A[5] [6] QO260NATS QO200TR QO200TRNM QO260NATR Box. No. [4] 2, 9R[7] 1NM 1R 120/240 Vac 100 A[8] QO2000NS QO2000NRB 13, 10R Service Table 1.
Enclosed Devices Non-Service Entrance Devices www.se.com/us Class 1130 / Refer to Catalog 1100CT0501 Table 1.99: QOM2 Enclosures and QOM2 Circuit Breakers Service QOM22225NF/S Type 3R Rainproof Box No. [17] Ampere Rating QOM22225NRB 22, 16R 100 A 125 A 150 A 175 A 200 A 225 A 1 2P 240 Vac Maximum 22 k AIR Cat. No.[18] QOM2100VH QOM2125VH QOM2150VH QOM2175VH QOM2200VH QOM2225VH Cat. No.
Servicepak™ Power Outlet Panels 1 Class 1140 www.se.com/us Power Outlet Panels for Construction Sites LOAD CENTERS • • • • • • • Provide temporary power at construction sites. Each receptacle protected by QO-GFI circuit breaker in compliance with NEC® requirements. Each enclosure is rainproof. 10 kA short circuit current rating. UL Listed as suitable for use as temporary site service equipment. Provided with neutral bonding provisions. Boxes have provisions for type “B’’ hubs to be field-installed.
Servicepak™ Power Outlet Panels www.se.com/us Class 1140 Power Outlet Configuration 12C 13C 14C 1Ø2W 1Ø2W 1Ø3W Mains Ampere Rating 50 A 75 A 100 A Circuit Breaker (Included) (1) QO120GFI (1) QO130 (2) QO130 (1) QO120GFI (2) QO130 (3) QO130 (1) QO120GFI (1) QO250 (1) QO130 (1) QO250 (2) QO130 Receptacles (Included) [10] Cat. No.