Specification
28
© 2007 Schneider Electric All Rights Reserved 03/2007
QO
®
Circuit Breaker Load Centers—Class 1130
QO Single-Phase Labels
QO SINGLE-PHASE LABELS
The labels below represent typical labels. Information may not be applicable or may change without notice. See the actual label in
the load center for the latest information.
QO Single-Phase Box Label Sample
QO Single-Phase Wiring Diagram Sample
Short circuit ratings.
Short circuit ratings and additional of
replacement circuit breakers.
LISTED
Electric
Cabinet Box
Issue No. V-2813
QO
®
LOAD CENTER
See Panelboard interior for Catalog No.
Box Cat. No. / Caja No. de Catalogo:
BX18C
Use Cover Cat. No. /
Utilice la Cubierta No. de Catalogo:
QOC16US or/or QOC16UF
Mains 125A max.
Lina principal de 125A maximo.
See main or service disconnect
rating if installed.
240 V ~ Max. 1Ø, 50 / 60 Hz.
24 circuit max. / 24 circuitos maximo.
Type 1 Enclosure
Gabinete Tipo 1
For installation, rep
airs or alterations,
Call an electrical contractor or electrician.
Panel
Rating
Remote
Main
Integral
Main
Branch (min.)/
Cat. prefix
*65,000 ---- Lugs 65,000 / QH
*42,000 ---- Lugs 42,000 / QOH
*22,000 ---- Lugs 22,000 / OQ.VH
*10,000 ---- Lugs 10,000 / OO, QOT & Q1
**5,000 ---- Lugs 5,000 / QO...H (2 pole)
100,000 --100-200A,300V T FuseLugs 10,000 / QO & QOT
42,0000 QOH Lugs 10,000 / QO & QOT
22,000 Q2...H, KD, QO...VH Lugs 10,000 / QO & QOT
65,000 KG Lugs 10,000 / QO & QOT
22,000 ---- QOM...VH 10,000 / QO, QOT & Q1
** 240 v ~ 3Ph. 3W. Grounded B” phase requires 240 V ~ branch
breakers.
* The rating is equal to the lowest interrupting rating of any circuit breaker
installed. Refer to branch breaker for individual ratings. Additional or
replacement branch circuit breakers, main breaker, or service disconnect
MUST have an interrupting r
ating equal to or greater than that of the
circuit breaker with the lowest interrupting rating presently installed.
See panelboard interior for breaker types.
LUG TORQUE DATA
See circuit breakers and field installed
units for wire binding screw torque
Branch Neutral and Equipment Ground Bar
Equipment Ground Combinations
Wire Range (AWG/kcmil) Torque (in/lbs.)
Line Neutral
Lug
4 - 2/0 CU/AL 50
Main Lug 6 - 2/0 CU/AL 50
Alternate
Main Breaker
See Main
Breaker
See Main
Breaker
Wire Range (AWG)
To r que (in./lbs.) Bar with 1
Bar with 2 screw sizesscrew size
1/0 - 3 CU / AL Large 50 Small
4 CU / AL Large 45 Small 35
6 CU / AL Large 45 Small 25 35
8 CU / AL Large 40 Small 10 25
10-14 CU, 10-12 AL La
rge 35 Small 10 20
Two 14 or 12 CU, Two 12 AL 3510 25
Two 10 AL 35 25
SHORT CIRCUIT RATING
RMS Symmetrical Amperes at 120 / 240 V ~ Maximum
Underwriter’s
Laboratories, Inc.®
Number of circuits maximum.
Enclosure catalog number.
Catalog number of covers; flush
or surface.
See panelboard interior for the
catalog number.
Volta ge ratings.
Amperage rating.
UL Listing.
001021 40265-381-0315
®
Install loose label with Spanish translation
on back of cover.
Adhiera la etiqueta suelta con las traducciones
en espanol en la parte posterior del frente.
Please read information before installing
Por favor lea la informacion antes de instalar.
~
/
Wire range for lug torque data table.
Made in U.S.A. 40265-668-0215
Suitable for use with 75
o
C
Copper or Aluminum
main conductors. See
branch breakers for
branch wire ratings.
* Suitable for use as service equipment when
service disconnect (main breaker) is installed.
* Suitable for use as service equipment when
not more than six main disconnecting means
are provided and when not used as a lighting
and appliance branch circuit panelboard.
See Article 384-14 of the NEC.
* When used as service equipment, all unused
neutral terminals may be used for terminating
equipment ground wires.
1. Box bonding when required. / Conexion a la caja
cuando fuese necesario.
2. Main breaker type: QOM1 or QOM1A. / Interruptor
automatico principal tipo: QOM1 o QOM1A.
3. Service ground
when required. /
Tierra de acometida
cuando fuese
necesario
4. Main lugs kit no:
QOL125. / No. de
accesorio de las
zapatas
principales:
QOL125.
Tw o single poles. One plug
on space or may us
e one
single pole. One two pole
requires two spaces.
To rque Note: When main
breaker or main lug
connector mounting nuts
are loosened or removed,
retighten to 75 lbs./in.
torque.
* May plug on two adjacent spaces.
Torque Note: When interior mounting screw is
loosened or removed, retighten to 35 lbs./in.
Load Center Accessories - Kits
PK4MB2LA Back-fed Main Cir. Brkr. Retaining
QO2175SBPlug-0n Surge Arrestor *
SDSA1175 1 Ph
ase Surge Arrestor
QOSAMK SDSA1175 Mounting Bracket
QOL2125 1 Phase Plug-on Subfeed Lugs *
PK9--27GTA(L) Equipment Ground Bar
PKGTAB Equipment Ground Bar Insulator
LK70AN 70A Max. Neutral Lug
LK100AN 125A Max. Neutral Lug
QOL125 Main Lugs
PK6FL Indoor Cover Lock
Equipment Grounding
Terminals
Service Equipment marking.
Use of unused neutral branch terminal for
equipment grounding, service equipment
application only.
Installation of back-fed main circuit breaker and
required kit.
Alternate wiring diagram for main circuit breaker or
main lug.
Load center accessories.
Neutral lug for 1/0 AWG or larger wire.
Type of circuit breakers
from Square D that
may be used in this
panelboard.
Line / Linea
N
N
O
O
3
N
O
O
1
2
4
LOAD / CARGAS
LOAD / CARGAS
LOAD / CARGAS
Main Breaker diagram Main Lugs diagram
N