Specification
Homeline
®
Circuit Breakers and Load Centers—Class 1170
Homeline Label Samples
52
© 2007 Schneider Electric All Rights Reserved 03/2007
HOMELINE
LABEL SAMPLES
For information on two-tier and three-tier series ratings, see Data Bulletin number 4100DB0301, Square D
®
Load Center Short
Circuit Current Ratings, located on the Technical Library at www.SquareD.com.
Install loose label with Spanish translation
on back of cover.
Adhiera la etiqueta suelta con las traducciones
en espanol en la parte posterior del frente.
Please read information before installing
Por favor lea la informacion antes de instalar.
~
/
LISTED
Electric
Cabinet Box
Issue No. V-2813
HOM LOAD CENTER
See Panelboard interior for Catalog No.
Box Cat. No. / Caja No. de Catalogo:
BXH34A
Use Cover Cat. No. /
Utilice la Cubierta No. de Catalogo:
HOMC30UC
Mains 200A max. / Lina Principal de.
200A maximo.
See main or service disconnect
rating if installed.
120/240 V ~ Max. 1Ø, 50 / 60 Hz.
30 circuit max. / 30 circuitos maximo.
Type 1 Enclosure
Gabinete Tipo 1
For installation, repairs or alterations,
Call an electrical contractor or electrician.
Panel
Rating
Remote
Main
Integral
Main
Branch (min.)/
Cat. prefix
42,000 QOH Lugs 10,000 / HOM
22,000 QOME..VH Lugs 10,000 / HOM
*10,000 ---- Lugs 10,000 HOM
22,000 ---- QOM2...VH 10,000 HOM
10,000 ---- QOM2 10,000 HOM
* The rating is equal to the lowest interrupting rating of any circuit breaker
installed. Refer to branch breaker for individual ratings. Additional or
replacement branch circuit breakers, main breaker, or service disconnect
MUST have an interrupting rating equal to or greater than that of the
circuit breaker with the lowest interrupting rating presently installed.
See panelboard interior for breaker types.
LUG TORQUE DATA
See circuit breakers and field installed
units for wire binding screw torque
Branch Neutral and Equipment Ground Bar
Equipment Ground Combinations
Wire Range (AWG/kcmil) Torque (in/lbs.)
Main Lug 4 - 250 CU/AL 250
Service
Ground Lug
6 - 2/0 CU/AL 50
Alternate
Main Breaker
See Main
Breaker
See Main
Breaker
Wire Range (AWG) Torque (in./lbs.)
6 CU / AL Large 45
8 CU / AL Large 40
14-10 CU, 12-10 AL Large 35
Two 14 or 12 CU 25
Two 12 or 10 AL 10
SHORT CIRCUIT RATING
RMS Symmetrical Amperes at 120 / 240 V ~ Maximum
Underwriter’s
Laboratories, Inc.®
Number of circuits maximum.
Enclosure catalog number.
Catalog number of covers; flush
or surface.
See panelboard interior for the
catalog number.
Voltage ratings.
Amperage rating. Wire range for lug torque data table.
Short circuit ratings.
Short circuit ratings and additional of replacement
circuit breakers.
UL listing.
001021 40265-381-0315
®
Homeline Box Label Sample
Line / Lines
N
N
O O
3
N
O
O
1
2
4
LOAD / CARGAS
LOAD / CARGAS
LOAD / CARGAS
Main Breaker diagram Main Lugs diagram
Service Equipment marking.
Use of unused neutral branch terminal for
equipment grounding, service equipment
application only.
Made in U.S.A. 40265-668-0215
1. Box bonding when required. / Conexion a la caja
cuando fuese necesario.
2. Main breaker type: QOM1 or QOM1A. / Interruptor
automatico principal tipo: QOM1 o QOM1A.
3. Service ground
when required. /
Tierra de acometida
cuando fuese
necesario
4. Main lugs kit no:
QOL125. / No. de
accesorio de las
zapatas
principales:
QOL125.
One single pole. One plug
on space. One two pole
requires two plug on
spaces.
Torque Note: When main
breaker or main lug
connector mounting nuts
are loosened or removed,
retighten to 75 lbs./in.
torque.
* May plug on two adjacent spaces.
Torque Note: When interior mounting screw is
loosened or removed, retighten to 35 lbs./in.
Load Center Accessories - Kits
HOM4K2LA Back-fed Main Circuit Brkr. Retaining
HOM2175SB Plug-0n Surge Arrestor *
SDSA1175 1 Phase Surge Arrestor
QOSAMK SDSA1175 Mounting Bracket
HOML2125 1 Phase Plug-on Subfeed Lugs *
PK9--27GTA(L) Equipment Ground Bar
PKGTAB Equipment Ground Bar Insulator
LK70AN 70A Max. Neutral Lug
LK100AN 125A Max. Neutral Lug
QOL125 Main Lugs
PK6FL Indoor Cover Lock
Equipment Grounding
Terminals
Type of circuit breakers
from Square D that
may be used in this
panelboard.
Installation of back-fed main circuit breaker and
required kit.
Alternate wiring diagram for main circuit breaker or
main lug.
Load center accessories.
Neutral lug for 1/0 AWG or larger wire.
Suitable for use with 75
o
C
Copper or Aluminum
main conductors. See
branch breakers for
branch wire ratings.
* Suitable for use as service equipment when
service disconnect (main breaker) is installed.
* Suitable for use as service equipment when
not more than six main disconnecting means
are provided and when not used as a lighting
and appliance branch circuit panelboard.
See Article 384-14 of the NEC.
* When used as service equipment, all unused
neutral terminals may be used for terminating
equipment ground wires.
Homeline Wiring Diagram Sample